Loading...
Bank One-LR031023CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94031289.0068 Service Date: October 15, 2003 'lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Bank One Texas NA Report Date: October 23, 2003 Attn: Danny Buckner Project: Bank One - Coppell TX 8111 Preston Suite 250 616 Nodh Denton Tap Rd Dallas TX 75225 Coppell, TX Project Number: 94031289 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: Supplier: LDJ Truck No: Mix I.D. No.: 60A Water Added Onsite Before Test: 10 Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Result Slump, inches: 5.25 Air Content, %: 3.4 Concrete Temperature, o F: 84 Ambient Temperature, o F: 78 Plastic Unit Weight, pcf: LaboratorV Test Data Set Specimen Diameter Area No. ID (inches) (sq. inches) 1 1 6.00 28.27 1 2 6.00 28.27 I 3 1 4 Ticket No: 51185 Sample Information sample Time: 4:07pm Date Cast: October 15, 2003 Technician: Thomas B. Combs Weather Conditions: Sunny Accumulative Yards: 20 Placement Method: Direct Discharge Sample Locations: 45' N of SE approach Placement Location: Parking Lot Specification Test Method ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 10/22/2003 7 86,200 3,050 10/22/2003 7 88,650 3,130 Average 3,090 11/12/2003 28 11/12/2003 28 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Thomas B. Combs Report Distribution: (1) Bank One Texas NA (1) City of Coppeil TX (1) Aguirre 8uJldit~g Systems (1) City of Coppell TX Reviewed by: /~Terracon Hussein H. Abusaad, PE. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1