Bank One-LR031010CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94031289.0042 Service Date: September 11, 2003 Client: Bank One Texas NA Attn: Danny Buckner 8111 Preston Suite 250 Dallas TX 75225 'lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: October 10, 2003 Project: Bank One - Coppell TX 616 North Denton Tap Rd Coppell, TX Project Number: 94031289 Material Information Specified Strength: 3500 psi @ 28 Days BatchTime: 1:48am Plant: 2 Supplier: LDJ Truck No: 747 Ticket No: 116051 Mix I.D. No.: 60 Water Added Onsite Before Test: 25 Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratorv Test Data Sample Information sample Time: 3:00am Date Cast: September 11,2003 Technician: James C. Blackwell Weather Conditions: Overcast,mild Accumulative Yards: 40 Placement Method: Chute Sample Locations: 50' W & 5' N of NW corner of bldg. Placement Location: Paving, W side Parking Lot & Entry off of Denton Tap. Result Specification Test Method 5.00 ASTM C-143 5.1 ASTM C-231 85 ASTM C-1064 67 ASTM C-1064 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 I 6.00 28.27 09/18/2003 7 105,450 3,730 1 2 6.00 28.27 09/18/2003 7 96,060 3,400 Average 3,570 1 3 6.00 28.27 10/09/2003 28 124,030 4,390 I 4 6.00 28.27 10/09/2003 28 121,860 4,310 Average 4,350 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, peFform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM. AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94031289.0042 Service Date: September 11, 2003 'lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Bank One Texas NA Attn: Danny Buckner 8111 Preston Suite 250 Dallas TX 75225 Report Date: October 10, 2003 Project: Bank One - Coppell TX 616 North Denton Tap Rd Coppell, TX Project Number: 94031289 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 2:32am Plant: 2 Supplier: LDJ Truck No: 728 Ticket No: 50275 Mix I.D. No.: 60 Water Added Onsite Before Test: 10 Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Result Slump, inches: 5.00 Air Content, %: 4.2 Concrete Temperature,° F: 86 Ambient Temperature, o F: 71 Plastic Unit Weight, pcf: Laboratorv Test Data Sample Information Sample Time: 4:22am Date Cast: September 11, 2003 Technician: James C. Blackwell Weather Conditions: Overcast- Mild Accumulative Yards: 100 Placement Method: Chute Sample Locations: 40' W & 20' S of SW corner of bldg. Placement Location: See page 1 Specification Test Method Set Specimen Diameter Area Date No. ID (inches) (sq. inches) Tested 2 1 6.00 28.27 09/18/2003 2 2 6.00 28.27 09/18/2003 2 3 6.00 28.27 10~09~2003 2 4 6.00 28.27 10/09~2003 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-1064 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 77,800 2,750 7 76,310 2,700 Average 2,730 28 108,160 3,820 28 109,990 3,890 Average 3,860 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: James C. Blackwell Report Distribution: (~) Bank One Texas NA (1) City of Coppell TX (1) Aguirre Building Systems (1) City el Coppell TX Reviewed by: Hussein H Abusaad, P.E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, °r DOT test meth°ds This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials Page 2 of 2