Bank One-LR031003CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94031289.0056 Service Date: September 25, 2003 Client: Bank One Texas NA Attn: Danny Buckner 8111 Preston Suite 250 Dallas TX 75225 'lrerracan 8901 Carpenter Frwy, Ste 11100 Dallas, Texas 75247 (214) 630-1010 Report Date: October 03, 2003 Project: Bank One - Coppell TX 616 North Denton Tap Rd Coppell, TX Project Number: 94031289 Material Informatio~- Specified Strength: 4000 psi ~ 28 Days Batch Time: Plant: 2 Supplier: LDJ Ready Mix Truck No: 725 Mix I.D. No.: 60A Water Added Onsite Before Test: Field Test Data Test Result Slump, inches: 6.00 Air Content, %: 4.8 Concrete Temperature,° F: 81 Ambient Temperature, o F: 69 Plastic Unit Weight, pcf: Laboratory Test Data set Specimen Diameter Area No. ID (inches) (sq. inches) 1 1 6.00 28.27 1 2 6.00 28.27 I 3 I 4 Ticket No: 35404 5 Gallons Sample Information sample Time: 5:1Sam Date Cast: September 25, 2003 Technician: Roy T. Montgomery Weather Conditions: Clear Accumulative Yards: 30 Placement Method: Direct Discharge Sample Locations: 28' N of SE entrance, 15' W of E curb Placement Location: Paving, SE corner of project Specification Test Method ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 10/02/2003 7 77,980 2,760 10/02/2003 7 80,870 2,860 Average 2,810 10/23/2003 28 10/23/2003 28 Comments: Not tested for plastic unit weight, Services - Obtain samples of fresh concrete at the placement Locations, perform required field tests and cast compressive strength samples. Technician: Roy T. Montgomery Report Distribution: (1) Bank One Texas NA (1) City of Coppell TX Reviewed by: HBC/Terracon Hus~ P.E. Senior Project Manager (1) City of Coppell TX The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracor~. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials Page 1 of 1