Bank One-LR030926CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 940312890027 Service Date: August 28, 2003 'lrerracan 8901 Carpenter FnN¥, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Bank One Texas NA Attn: Danny Buckner 8111 Preston Suite 250 Dallas TX 75225 Report Date: September 26, 2003 Project: Bank One - Coppell TX 616 North Denton Tap Rd Coppell, TX Project Number: 94031289 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 11:05am Supplier: LDJ Truck No: 739 Mix I.D. No.: 50A Plant: 02 Ticket No: Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 5.78 6.6 95 92 Set Specimen Diameter Area No. ID (inches) (sq. inches) 1 1 6.00 28.27 1 2 6.00 28.27 1 3 6.00 28.27 1 4 6.00 28.27 Sample Information Sample Time: 12:30pm Date Cast: August 28, 2003 Technician: Eddie A. Elrod Weather Conditions: Partly cloudy Accumulative Yards: 10 Placement Method: Pump Sample Locations: C-.3/1 Placement Location: Grade beam for entire building Note: Wrong mix designed placed. It was approved by Structural Engineer before placement. Specification 3-5 Test Method ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 09/04/2003 7 71,980 2,550 09/04/2003 7 74,390 2,630 Average 2,590 09/25/2003 28 93,760 3,320 09/25/2003 28 92,830 3,280 Average 3,300 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Eddie A. Elrod Report Distribution: (1) Bank One Texas NA (1) City of Ceppell TX (1) Aguirre Building Systems (1) City of Coppell TX Reviewed by: HBC/Terracon Hussein H. Abusaad, P.E Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical rnateriats Page 1 of 1 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94031289.0026 Service Date: August 28, 2003 'lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Bank One Texas NA Attn: Danny Buckner 8111 Preston Suite 250 Dallas TX 75225 Report Date: September26, 2003 Project: Bank One - Coppell TX 616 North Denton Tap Rd Coppell, TX Project Number: 94031289 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 2:23am Supplier: LDJ Truck No: 747 Mix I.D. No.: 660AB Plant: 02 Field Test Data Test Ticket No: 34947 Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Sample Information Sample Time: 3:55am Date Cast:August 28, 2003 Technician: Eddie A. Elrod Weather Conditions: Clear Placement Method: Direct Discharge Sample Locations: See attached sketch Placement Location: Paving Result Specification Test Method 5.75 ASTM C-143 3.8 ASTM C-231 88 ASTM C-1064 76 ASTM C-1064 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 09~04~2003 7 78,190 2,760 1 2 6.00 28.27 09/04~2003 7 81,850 2,890 Average 2,830 1 3 6.00 28.27 09/25/2003 28 114,600 4,050 1 4 6.00 28.27 09/25/2003 28 117,040 4,140 Average 4,100 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods This report is exclusivety for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94031289.0026 Service Date: August 28, 2003 'lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Bank One Texas NA Attn: Danny Buckner 8111 Preston Suite 250 Dallas TX 75225 Report Date: September 26, 2003 Project: Bank One - Coppell TX 616 Nodh Denton Tap Rd Coppell, TX Project Number: 94031289 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 3:05am Supplier: LDJ Truck No: 728 Mix I.D. No.: 660AB Plant: 02 Field Test Data Test Ticket No: 49878 Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Sample Information Sample Time: 5:35am Date Cast: August 28, 2003 Technician: Eddie A. Elrod Weather Conditions: Clear Accumulative Yards: 130 Placement Method: Direct Discharge Sample Locations: See page 1 Placement Location: See page 1 Result Specification Test Method 5.75 ASTM C-143 4.3 ASTM C-231 89 ASTM C-1064 77 ASTM C-1064 Laboratorv Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 2 1 6.00 28.27 09~04~2003 7 73,690 2,610 2 2 6.00 28.27 09~04~2003 7 77,630 2,750 Average 2,680 2 3 6.00 28.27 09/25/2003 28 103,880 3,670 2 4 6.00 28.27 09/25/2003 28 106,140 3,750 Average 3,710 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Eddie A. Elrod Report Distribution: (1) Bank One Texas NA (1) City o1Coppell TX (1) Agui[re Building Systems (1) City of Coppell TX Reviewed by: HBC/Terracon Hussein H Abusaad, PE Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials