Bank One-LR030825FIELD DENSITY TESTING Report Number: 94031289,0015 Service Date: August 15, 2003 ']rerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Sank One Texas NA Attn: Danny Buckner 8111 Preston Suite 250 Dallas TX 75225 Report Date: August 25, 2003 Project: Bank One - Coppell TX 616 North Denton Tap Rd Coppell, TX Project Number: 94031289 Material Information Material Laboratory Content No. Test Method Description and Classification (%) Lab Test Data Optimum Max. Lab Water Dry Unit Weight (pcf) 1. 312890001 ASTM D 698 Tan & gray silty shaley clay w/sand 15.3 107.5 Field Test Data Probe Water Test LiffJ Mat. Depth Content No. Test Location Elevation No. (inches) (%) Prelect Requirements Water Content Minimum Dry R ~aP4A,e Unit Weight /,"~o ) / (% compaction) -1/+ 95 Dry Unit Dr,/Unit Weight Weight (pot') (% compaction) 4" Sanitary Sewer 26 Sra. 0+30 4' BEG 1 6 17.5 102.2 95 27 Sra. 0+30 3' BEG 1 6 16,4 103.2 96 28 Sta. 0+30 2' BEG 1 6 17.1 103.0 96 29 Sra. 0+30 1' BEG I 6 ....1..~...0~.. 102.8 96 30 Sta. 0+30 Final I 6 ~/')1 102.0 95 Datum: BEG = below existing grade Comments: Test results on this report meet project specification. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method:ASTM D2922, ASTM D3017 Gauge ID: 32769 Technician: James L. Atnip Report Distribution: (1) Bank One Texas NA (1) City of Coppell TX (1) Aguirre Building Systems (1) City of Coppell TX Reviewed by: Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are on[y applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 940312890018 Service Date: August 15, 2003 'lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Bank One Texas NA Attn: Danny Buckner 8111 Preston Suite 250 Dallas TX 75225 Report Date: August 25, 2003 Project: Bank One - Coppell TX 616 North Denton Tap Rd Coppell, TX Project Number: 94031289 Material Information Specified Strength: 3000 psi @ 28 Days BatchTime: 11:21am Plant: 02 Supplier: LDJ Ready Mix Truck No: 731 Mix I.D. No.: 50 Water Added Onsite Before Test: Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature,° F Plastic Unit Weight, pcf: Laboratory Test Data Ticket No: 34753 5 Gallons Result 6.00 1.2 87 85 Set Specimen Diameter Area No ID (inches) (sq. inches) 1 1 6.00 26.27 1 2 6.00 26.27 3 4 Sample Information Sample Time: 12:25pm Date Cast:August 15, 2003 Technician: Eddie A EIrod Weather Conditions: Clear Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: Piers D/9, E/6.3, E/5, D.9/3 Placement Location: Piers- See Report #940312890017 Specification Test Method ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 08/22/2003 7 88,830 3,140 08/22/2003 7 89,840 3,180 Average 3,160 09/12/2003 28 09/12/2003 28 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Eddie A. Elrod Report Distribution: (1) Bank One Texas NA (1) Cily of Coppell TX (1) Agui(re Suilding Systems (1) City of Coppetl TX Reviewed by: Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods This report is exclusively for the use of the client indicated above and shall not be reproduced except in full wilhout the written approval of Terracon Test results transmitted herein are only applicable to the actual samples tested at the Iocabon(s) reterenced and are not necessarily indicative of the properties of other apparently similar or identical materials Page 1 of 1