Bank One-LR030822CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94031289.0014
Service Date: August 14, 2003
'lrerracon
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
Client: Bank One Texas NA
Attn: Danny Buckner
8111 Preston Suite 250
Dallas TX 75225
Report Date: August 22, 2003
Project: Bank One - Coppell TX
616 NoAh Denton Tap Rd
Coppell, TX
Project Number: 94031289
Material Information
Specified Strength: 3000 psi @ 28 Days
Batch Time: 10:12am Plant: 02
Supplier: LDJ Ready Mix
Truck No: 723
Mix I.D. No.: 50A
Field Test Data
Test
Slump, inches:
Air Content, %:
Concrete Temperature, o F:
Ambient Temperature, o F:
Plastic Unit Weight, pcf:
Laboratory Test Data
Result
5.50
4.4
88
86
Set Specimen Diameter Area
No. ID (inches) (sq. inches)
1
2
3
4
5
6
Ticket No: 34742
Sample Information
Sample Time: 12:15pm Date Cast:August 14, 2003
Technician: Eddie A. Eirod
Weather Conditions: Padly cloudy
Accumulative Yards: 10
Placement Method: Direct Discharge
Sample Locations: Piers- C/8, C.5/8, C.9/8, E/9
Placement Location: Piers- See Report #94031289.0013
Note: The wrong mix was put in piers,
Structural Engineers said to use if air was
B/T 4-6%
Specification Test Method
Date
Tested
6.00 28.27 08/21/2003
6.00 28.27 08/21/2003
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-1064
08/28~2003
Age at Maximum Compressive
Test Load Strength
(days) (lbs) (psi)
7 66,170 2,340
7 62,160 2,200
Average 2,270
14
09/04/2003 21
09/11/2003 28
09/11/2003 28
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written appr°val °f Terrac°n Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
Page 1 of 2
'lrerr can
CONCRETE COMPRESSIVE STRENGTH TEST
Client: Bank One Texas NA Project Number:94031289
Report Number: 94031289.0014
Comments (cont'd):
Comments: Not tested for plastic unit weight.
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
Technician: Eddie A. Elrod
Repod Distribution:
(1) Bank One Texas NA
(1) City of Coppell TX
(1) Aguirre Building Systems
(1) City ol Coppell TX
Reviewed by:
n
Hussein H. Abusaad, PE.
Senior Project Manager
The tests were performed in general accordance with applicable ASTM, AASHTO, °r DOT test rneth°ds This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials
CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94031289.0016
Service Date: August 14, 2003
']l'erracan
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
Client: Bank One Texas NA
Attn: Danny Buckner
8111 Preston Suite 250
Dallas TX 75225
Report Date: August 22, 2003
Project: Bank One - Coppell TX
616 North Denton Tap Rd
Coppell, TX
Project Number: 94031289
Material Information
Specified Strength: 3000 psi @ 28 Days
Batch Time: 1:38pm Plant: 02
Supplier: LDJ
Truck No: 731 Ticket No: 34744
Mix I.D. No.: 50
Water Added Onsite Before Test: 10 Gallons
Field Test Data
Test Result
Slump, inches: 6.00
Air Content, %: 0.9
Concrete Temperature, o F: 88
Ambient Temperature, o F: 88
Plastic Unit Weight, pcf:
Laboratory Test Data
Sample Information
Sample Time: 1:45pm Date Cast: August 14, 2003
Technician: Eddie A. Elrod
Weather Conditions: Cloudy
Accumulative Yards: 10
Placement Method: Direct Discharge
Sample Locations: Piers- B/3.6, B.1/7.1, B/5.6, B.1/1.9
Placement Location: Piers- See Report #94031289.0013
Specification Test Method
Set Specimen Diameter Area Date
No ID (inches) (sq inches) Tested
1 1 6.00 28.27 08/21/2003
1 2 6.00 28.27 08/21/2003
1 3 08/28/2003
1 4
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-1064
Age at Maximum Compressive
Test Load Strength
(days) (lbs) (psi)
7 83,890 2,970
7 81,880 2,900
Average 2,940
14
09/04/2003 21
1 5 09/11/2003 28
1 6 09/11/2003 28
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
Page 1 of 2
CONCRETE COMPRESSIVE STRENGTH TEST ~
'll'erracan
Client: Bank One Texas NA
Project Number:94031289
Report Number: 94031289.0016
Comments (cont'd):
Comments: Not tested for plastic unit weight.
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
Technician: Eddie A. Elrod
Report Distribution:
(1) Bank One Texas NA
(1) City of Coppell TX
(1) Aguirle Building Systems
(1) Cily of Coppell TX
~acon
ev,ew d ,:
Hus H Abusaad, P.E
Manager
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods This report is exclusivety for the use of the client
indicated above and shall not be reproduced except iR full without the written approval of Terracon Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials