Bank One-LR030806FIELD DENSITY TESTING Report Number: 94031289.0007 Service Date: July 29, 2003 'll'erracon 8901 Carpenter Frye/, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Bank One Texas NA Attn: Danny Buckner 8111 Preston Suite 250 Dallas TX 75225 Report Date: August 06, 2003 Project: Bank One - Coppell TX 616 North Denton Tap Rd Coppell, TX Project Number: 94031289 Material Information Material Laboratory No. Test Method Description and Classification Lab Test Data Proiect Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Content Weight Range Unit Weight (%) (pcf) (%) (% compaction) 1. 312890005 ASTM D 698 Tan silty clayey sand 12.8 118.5 -2/+2 95 Field Test Data Probe Water Dry Unit Dry Unit Test Lift/ Mat. Depth Content Weight Weight No. Test Location Elevation No. (inches) (%) (pot} (% compaction) Building Pad, Select Fill 15 20' N & 15' W of SE building corner Final 1 6 16 20' S & 30' E of NW building corner Final 1 6 11,0 111.1 94 10.0 * 110.0 93 Comments: An asterisk (*) appears next to test results which do NOT meet the project specifications. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method~,STM D2922, ASTM D3017 Gauge ID: 32769 Field Results Reported To: Contractor Technician: James L. Atnip Report Distribution: (1) Bank One Texas NA (1) City of Coppell TX (1) Aguirre Building Systems (1) City of Coppell TX Reviewed by: Husse[n H. Abusaad, P.E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable te the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently sfmilar or identical materials. Page 1 of I REPORT OF IN-PLACE DENSITY TESTS Report Number: 94031289.0006 Service Date: July 28, 2003 'irerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Bank One Texas NA Attn: Danny Buckner 8111 Preston Suite 250 Dallas TX 75225 Report Date: August 06, 2003 Project: Bank One - Coppell TX 616 Nodh Denton Tap Rd Coppell, TX Project Number: 94031289 Services: In-place density tests. On this date, HBC/Terracon's technician arrived at the above referenced jobsite as scheduled for in-place density tests. After arriving at the jobsite, HBC/Terracon's technician was notified that in-place density tests were cancelled due to the contractor.was not ready for tests. Technician: James L. Atnip Report Distribution: (1) Bank One Texas NA (1) City of CoppelJ TX (1) Aguirre Building Systems (1) City of Ceppell TX Reviewed by: Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials Page ~ of 1