Bank One-LR030806FIELD DENSITY TESTING
Report Number: 94031289.0007
Service Date: July 29, 2003
'll'erracon
8901 Carpenter Frye/, Ste #100
Dallas, Texas 75247
(214) 630-1010
Client: Bank One Texas NA
Attn: Danny Buckner
8111 Preston Suite 250
Dallas TX 75225
Report Date: August 06, 2003
Project: Bank One - Coppell TX
616 North Denton Tap Rd
Coppell, TX
Project Number: 94031289
Material Information
Material Laboratory
No. Test Method
Description and Classification
Lab Test Data Proiect Requirements
Optimum Max. Lab Water
Water Dry Unit Content Minimum Dry
Content Weight Range Unit Weight
(%) (pcf) (%) (% compaction)
1. 312890005 ASTM D 698 Tan silty clayey sand 12.8 118.5 -2/+2 95
Field Test Data Probe Water Dry Unit Dry Unit
Test Lift/ Mat. Depth Content Weight Weight
No. Test Location Elevation No. (inches) (%) (pot} (% compaction)
Building Pad, Select Fill
15 20' N & 15' W of SE building corner Final 1 6
16 20' S & 30' E of NW building corner Final 1 6
11,0 111.1 94
10.0 * 110.0 93
Comments:
An asterisk (*) appears next to test results which do NOT meet the project specifications.
Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture
condition.
Field Test Method~,STM D2922, ASTM D3017
Gauge ID: 32769
Field Results Reported To: Contractor
Technician: James L. Atnip
Report Distribution:
(1) Bank One Texas NA
(1) City of Coppell TX
(1) Aguirre Building Systems
(1) City of Coppell TX
Reviewed by:
Husse[n H. Abusaad, P.E.
Senior Project Manager
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
te the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently sfmilar or identical
materials.
Page 1 of I
REPORT OF IN-PLACE DENSITY TESTS
Report Number: 94031289.0006
Service Date: July 28, 2003
'irerracon
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
Client: Bank One Texas NA
Attn: Danny Buckner
8111 Preston Suite 250
Dallas TX 75225
Report Date: August 06, 2003
Project: Bank One - Coppell TX
616 Nodh Denton Tap Rd
Coppell, TX
Project Number: 94031289
Services: In-place density tests.
On this date, HBC/Terracon's technician arrived at the above referenced jobsite as scheduled for
in-place density tests. After arriving at the jobsite, HBC/Terracon's technician was notified that
in-place density tests were cancelled due to the contractor.was not ready for tests.
Technician: James L. Atnip
Report Distribution:
(1) Bank One Texas NA
(1) City of CoppelJ TX
(1) Aguirre Building Systems
(1) City of Ceppell TX
Reviewed by:
Senior Project Manager
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials