Bank One-LR030801FIELD DENSITY TESTING Report Number: 94031289.0004 Service Date: July 26, 2003 ']rerrecon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Bank One Texas NA Attn: Danny Buckner 8111 Preston Suite 250 Dallas TX 75225 Report Date: August 01, 2003 Project: Bank One - Coppell TX 616 No~lh Denton Tap Rd Coppell, TX Project Number: 94031289 Material Information Material Laboratory No. Test Method Description and Classification Lab Test Data Project Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Content Weight Range Unit Weight (%) (pcf) (%) (% compaction) 1. 312890001 ASTM D 698 Tan & gray silty shaley clay w/sand 15.3 107.5 =/> +4 92 Field Test Data Probe Water Dry Unit Dry Unit Test Lift/ Mat. Depth Content Weight Weight No. Test Location Elevation No. (inches) (%) (pcf) (% compaction) Moisture Conditioned Building Pad 9 Retest of #7, dated 07/25/03 1 6 21.3 98.5 92 10 Retest of #8, dated 07/25/03 1 6 20.6 99.2 92 11 15' S & 15' W of NE building corner 4th 1 6 19.9 99.0 92 12 15' S & 15' W of NE building corner 5th 1 6 19.5 99.6 93 13 20' N & 10' E of SW building corner 4th 1 6 20.1 98.7 92 14 20' N & 10' E of SW building corner 5th 1 6 19.4 100.3 93 Comments: Test results on this report meet project specification. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method:ASTM D2922, ASTM D3017 Gauge ID: 32769 Technician: James L. Atnip Report Distribution: (1) Bank One Texas NA (1) City of CoppeJl TX (1) Aguirre Building Systems (1) City of Coppell TX Reviewed by_.' Hussein H. Abusaad, P.E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the wdtten approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials Page 1 of 1 FIELD DENSITY TESTING Report Number: 94031289.0003 Service Date: July 25, 2003 'lFerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Bank One Texas NA Attn: Danny Buckner 8111 Preston Suite 250 Dallas TX 75225 Report Date: August 01,2003 Project: Bank One - Coppell TX 616 North Denton Tap Rd Coppell, TX Project Number: 94031289 Material Information Material Laboratory No. Test Method Description and Classification Lab Test Data Prelect Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Content Weight Range Unit Weight (%) (poi) (%) (% compaction) 1.312890001 ASTM D 698 Tan & gray silty shaley clay w/sand Field Test Data Probe Test Lift/ Mat. Depth No. Test Location EIevation No. (inches) Moisture Conditioned Bldg Pad 1 25' S and 20' E of NW building corner Subgrade 1 6 2 25' S and 20' E o1 NW building corner 1st 1 6 3 30' N and 15' W of SE building corner Subgrade 1 6 4 30' N and 15' W of SE building corner 1st 1 6 5 10' N and 10' E of SW building corner 2nd 1 6 6 15' S and 25' W of NE building corner 2nd 1 6 7 15' S and 15' E of NW building corner 3rd 1 6 8 10' N and 15'W of SE building corner 3rd 1 6 15.3 107.5 =/> +4 92 Water Dry Unit Dry Unit Content Weight Weight (%) (pcf) (% compaction) 22.6 98.6 92 20.3 99.8 93 19.4 98.8 92 19.6 99.2 92 19.4 99.4 92 19.8 98.9 92 17.6 * 100.2 93 17.2 * 100.6 94 Comments: An asterisk (*) appears next to test results which do NOT meet the project specifications. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method:ASTM D2922, ASTM D3017 Gauge ID: 32769 Technician: James L. Atnip Report Distribution: (1) Bank One Texas NA (1) City of Coppell TX (1) Aguirre Building Systems (1) City of Coppell TX Reviewed by: H BC/Terracon Hu~aad, P,E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparentiy similar or identical materials. Page 1 of 1 LABORATORY COMPACTION CHARACTERISTICS OF SOIL Report Number: 94031289.0005 Service Date: July 25, 2003 'll'erracon 8901 Carpenter Frwy, Sle #100 Dallas, Texas 75247 (214) 630-1010 Client: Bank One Texas NA Attn: Danny Buckner 8111 Preston Suite 250 Dallas TX 75225 Report Date: August 01, 2003 Project: Bank One - Coppell TX 616 North Denton Tap Rd Coppelt, TX Project Number: 94031289 Material Information Contractor: Source of Material:Imported Material Proposed Use: Select Fill USCS: Laboratorv Test Data Test Procedure: Test Method: Sample Preparation: Rammer Type: Maximum Dry Unit Weight, pcf: 118.5 Optimum Water Content, %: 12.8 Sample Information Sampled By: James L. Atnip Sample Location: On-site stockpile Sample Description: Tan silty clayey sand ASTM D 698 Method A Moist Method Mechanical Liquid Limit: Plastic Limit: Plasticity Index: % Passing #200: % Passing % In-Place Moisture: Moisture Density Relations Zero Air Voids Curve for assumed specific gravity 265 Result 22 14 8 Specifications Services- Moisture-Density Relations Technician: James L. Atnip Report Distribution: (1) Bank One Texas NA (1) City of Coppell TX (1) Aguirre Building Systems (1) City of Coppell TX Reviewed by: HusseinH Abusaad, PE Senior Project Mana9er The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials Page 1 of 1 LABORATORY COMPACTION CHARACTERISTICS OF SOIL Report Number: 94031289.0001 Service Date: July 22, 2003 'lrerracon 8901 Carpen[er Frwy, gte #100 Dallas, Texas 75247 (214) 630-1010 Client: Bank One Texas NA Attn: Danny Buckner 8111 Preston Suite 250 Dallas TX 75225 Report Date: August 01, 2003 Project: Bank One - Coppell TX 616 North Denton Tap Rd Coppell, TX Project Number: 94031289 Material Information Contractor: Source of Material:Test Pit - Center Pad Proposed Use: Building Pad USCS: Laboratory Test Data Test Procedure: Test Method: Sample Preparation: Rammer Type: Maximum Dry Unit Weight, pcf: 107.5 Optimum Water Content, %: 15.3 Sample Information Sampled By: James C. Blackwell Sample Location: 5' below existing grade Sample Description: Tan & gray silty shaley clay w/sand Result Specifications ASTM D 698 Liquid Limit: 43 Method A Plastic Limit: 17 Moist Method Plasticity Index: 26 Mechanical % Passing #200: % Passing #40: % In-Place Moisture: Moisture Density Relations Zero Air Voids Curve for assumed specific gravity 265 Services- Moisture-Density Relations Technician: James C. Blackwell Report Distribution: (1) Bank One Texas NA (1) City of Coppell TX (1) Aguirre Building Systems (1) City of Coppell TX Reviewed by: Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials Page 1 of 1 ~ KS,R~ ~,,,,,..~