Loading...
Sandy Lk Med-LR031218Client: Project: CF Jordan Coppel[ Health Center SPECTRUM GLOBAL SERVICES, INC. 4552 8eltway Drfve Addfson, Texas 75001 Report of Concrete Compression Testfn¢, Distribution: Report No. Technician: 03-1041-24 K. Golden Specifications Test Data File Index: CON Strength (psi): 4000 Slump (in.): Air Content (%): Concrete Temp (°F Ticket #: 122335 Slump (in.): 4 1/4 Concrete Temp (°F): 63 Sample Location: Rema~s: Placement Date: 12/18/03 Weather: Clear-Cool Supplier/Mix: Redi-Mix Air Content Method: C231/C173 Set#1 Time Batched: Air Content (%): Air Temp. (°F): 48 Time Sampled: Unit Weight (pcf): Yardage (c.y.): Concrete Paving, S Perking Area 30' N & 20' E of the southwest comer of the slab. 9:15 N/A 30 of 60 SpeclmenlD Date Tested Age Max Load Area(in2) Streng~ Fra~. Notes 13 12/25 7 118660 28.27 4195 14 1/15 28 140510 28.27 4970 15 1/15 28 140210 28.27 4960 16 H H Respectfully submitted. Spectrum GIoDat Services. Inc,