Loading...
Hidden Valley-CS040205DEVELOPMENT REVIEW COMMITTEE ENGINEERING COMMENTS ITEM: Hidden Vaile¥~ Final Plat~ to allow a 16-lot single-family subdivision on 7.3 acres of property zoned PD-106-SF-9, located along the southerly extension of Hidden Valley Road, at the request Dowdey, Anderson & Associates, Inc. STAFF REP.: Gary Sieb PROJECT ID# FP-04-0004 DRC DATE: January 29, 2004 and February 5, 2004 CONTACT: Kenneth M. Gri~n, P.E., Ci~ En~,ineer (972)304-3686 COMMENT STA TUS: I S~g~gl~q4V~g.Y */FINAL AFTER P~Z Preliminary Utility Plans 1. Please explain how you intend to tap a 6" water line with an 8" water line. The 6" water line you are proposing to tie into is approximately a 25-year-old cast iron water line. We have problems with the cast iron water lines in the Northlake Woodlands developments. We have recently just replaced a substantial amount of that water line along Meadowcreek Road. I would strongly recommend that you install an 8" water line on the east side of lot 6 all the way to Meadowcreek Road and connect to the new 8" PVC water line on the south side of Meadowcreek Road. I am concerned that tying into the 6" cast iron line that is 25 years old could be a source of problems once these homes are developed. When the final plans are submitted, there could be additional comments made on the outfall of the stormdrain to the south. Without knowing the actual outfall velocity, it is difficult to ascertain whether the pipe should be extended all the way to the Meadowcreek Road storm sewer system.