PA9702-LR 990720 (2) CONCRETE COMPRESSIVE STRENGTH TESI 8901 Carl:enter Frwy., Suite #100 D~,!!~ Texas 75247 Dateof Service: 06/17/1999 Report No,: 9916671 Report Date 07/20/1999 Client No,: COPPELL Project No,: 94991118 Client: City of Co pell Project: Coppell Aquatic/Recreation Ctr Attn: Bra~Reid 732 DeForest 300 Block of Parkway Blvd Coppell TX 75019 Coppell, Tex~s/Prj. t~"96051 Services: Obtain samp~es ~f fresh c~ncrete at the p~acement ~ocati~ns~ pcrf~nn required ~e~d test and cast compressivc strength samples. PROJECT DATA COSTP, ACXOa: Hisaw & Assoc. CONCP, ET~ Ct,ASS: 6 Sack CONCRETE SUPPLIER: Nelson Brothers PLACEMENT DATE: 06/17/1999 BATCHTIFaE: ll:43am p~A~rr: Lewisville T~ SAMPLED: 12:50pm RY: Mike Odom SPECIFICATION REQUIREMENTS WEATHER cosnrnoNs: Cloudy STRENGTH: 4000 psi @ 28 Days ~MeEP. AVtnU~ (F) - AIR 79 F CONCRETE: 34 F SLUMI': 4-6" TRUCK NO: 2.24 TICKET NO: 73660 Ant: N/A Amcot~rr~r(%): N/A UNITWEIGHT(pcf~: b//A TEST M~T~On: ASTM C- 143 PLACEMENT LOCATION: Pier information and technician time: See Report ~s)916670 ASTM C-172 ASTM C-39 Pive (5) gallons of water added SAMPLE LOCATION: G-9 REPORT OF TESTS ^cct n A w vAp, s: 30 CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) 0bs- force) (psi) TYPE 1 1 4.25 06/24/1999 7 1205 10 4260 1 2 4.25 06/24/1999 7 127210 4500 Average 4380 1 3 4.25 07/15/1999 28 143200 5060 1 4 4.25 07/15/1999 28 146810 5190 Average 5130 Technician: Mike Odom Started: Finished: ~ Eng;/~i~ Report Distribution: (1) City of Coppell (I) City ofCoppell - Engineering (I) BrinkIcy Sargent Architects (I) City of Coppelt - Bldg. lnsp. Eugene I--Iarbour (1) Turner Engineers (l) City of Coppell * Leisure Serv Dcpt Vice President (1) Hisaw & Associates This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC hagiuesling, inc. 0ILL Page I of I