DR9306-SP 950203February 03, 1995 TEXAS INDUSTRIES, INC. 1341 W. MOCKINGBIRD LANE · DALLAS, TEXAS 75247-6913 · (214) 647-6700 M.A. Vinson Construction Comp. P.O. Box 185577 Fort Worth, TX 7618] Attention Mr. Roy Hynds RE: Stream G-6 @ Bethel School Rd. 8272 Gentlemen: The attached concrete mix design utilizing the appropriate ASTM C-33 or ASTM C-330 aggregate is proposed for use on the above referenced project for ready mix concrete to be furnished by TXI. To ensure that the correct mix is delivered to your project, please order by the mix design number which appears in the upper left hand corner of the mix design. Texas Industries certifies that the above mix design, when ordered by specified design identity, will meet or exceed the indicated design strength at a designated age when tested in accordance with the applicable and current ASTM Standards C 31, C 39, C 78, C 172, C 293, applicable provisions of C 94, and evaluated in accordance with applicable provisions of the ACI 318 Building Code. TXI would like to be included on your mailing list to receive all test reports. ASTM C 94-86a Section 14.4 entitles a manufacturer to receive copies of all test reports when strength of concrete is used as a basis for acceptance. Contact us if you have any questions or require any additional information. Please notify TXI of approval of the proposed mix design prior to its use. To ensure that the proper mix design is ordered, please send a copy of this letter, after approval, to the above referenced project to be used by the person ordering the concrete for this job. Sincerely, TEXAS INDUSTRIES, INC. Dana L. Link Customer Service Coordinator MIX # 8272 5.00SK ADMIX/AEA 1"CS 3000 PSI @ 28 Days AS REQUIRED Maximum Coarse Aggregate Size: ASTM C 33 1"- #4 Crushed Stone Maximum Water/Cement Ratio: 6.40 gal/sk .567 lb/lb Minimum Cement Content per Cubic Yard: 5.00 sacks Maximum Placement Slump: 5.0 inches Admixture ASTM C-494: Type A or D Air Entraining Agent ASTM C-260: 3% - 6% MATERIAL QUANTITIES PER I CUBIC YARD AT S.S.D. 470 lbs. or 5.00 sacks ASTM C 150 Type I Cement 1840 lbs. ASTM C 33 1"- #4 Crushed Stone 1352 lbs. ASTM C 33 Concrete Sand 267 lbs. or 32.0 gallons of Water 2.0 to 4.0 oz/cwt of ASTM C-494 Type A Specified Air Content: 3% - 6% Placement Slump: 4.0 + or - 1 inches PUMPING RECOMMENDATIONS 1. 5" minimum diameter lines with no reduction to smaller lines. 2. Keep rubber hose to absolute minimum length and plan pipe with as few 90 degree angles as possible. 3. Slumps and test cylinders should be taken @ discharge end of hose for strength guarantee to be valid. 4. To prime pump lines, a minimum of 8.0 sack grout should be used for lubrication. In the case of strength concrete, equivalent strength grout should be used if the grout remains in the placement. 5. Pump mixes are based on minimum cement content pumped at ground level. As pump line increases in length or height and/or layout configuration changes, additional cement may be required to assure strength and pumpability at additional cost to the contractor. We are enclosing all available back up data for the above referenced mix design. If the strength information is not available or is not sufficient, conformation cylinders may have to be made by your testing laboratory. Date: 02/03/95 TEXAS INDUSTRIES, INC. CONCRETE DESIGN EVALUATION ** Statistics Compiled From Independent Laboratory Test Specimens ** Mix Mo. ES272 Strength 3000 p~i @ 28 Days 28 Day Test Data Page: 1 Test Plant Temperature Placement Percent ....... 28 Day ....... Cum Moving No. Date No. Amb Con Slump of Air PSI 1 PSI 2 PSI Avg Avg Avg of 3 Range 1 09/28/94 46 N/A 84 4.5 5.0 3790 3810 3800 3800 3800 20 2 09/28/94 46 N/A 84 5.0 5.0 3930 3670 3800 3800 3800 260 3 09/28/94 46 N/A 84 5.5 5.0 3860 4000 3930 3843 3843 140 4 09/28/94 46 N/A 86 4.0 4.5 4360 4240 4300 3958 4010 120 5 09/29/94 42 94 93 4.0 M/A 3680 3970 3825 3931 4018 290 6 09/30/94 46 N/A 85 3.2 4.7 4870 4830 4850 4084 4325 40 7 10/03/94 46 N/A 92 §.0 5.1 4730 4680 4705 4173 4460 50 8 10/03/94 13 77 82 4.2 N/A 5710 6160 5935 4393 5163 450 9 10/03/94 13 80 83 5.0 N/A 5210 5440 5325 4497 5322 230 10 10/04/94 46 N/A 91 5.5 4.7 3920 4000 3960 4443 5073 80 11 10/05/94 46 M/A 90 4.5 M/A 4320 4580 4450 4444 4578 260 12 10/06/94 46 N/A 90 4.5 5.0 4550 4600 4575 4455 4328 50 13 10/07/94 46 N/A 89 4.7 5.0 5130 4950 ~040 4500 4688 180 14 10/07/94 46 M/A 88 5.5 4.9 4430 4350 4390 4492 4668 80 15 10/07/94 46 N/A 87 6.0 4.8 4050 4050 4050 4462 4493 16 10/07/94 46 N/A 89 4.7 M/A 4380 4410 4395 4458 4278 30 17 10/10/94 46 M/A 83 5.0 5.1 5450 5370 5410 4514 4618 80 18 10/12/94 35 75 84 6.7 4.5 4260 4410 4335 4504 4713 150 19 10/13/94 13 65 77 5.0 N/A 4430 4410 4420 4500 4722 20 20 10/17/94 12 75 M/A 3.0 N/A 4120 3940 4030 4476 4262 180 21 10/26/94 12 70 80 4.0 4.0 4580 4930 4755 4490 4402 350 22 10/28/94 13 75 N/A 4.5 N/A 3590 3800 3695 4453 4160 210 23 10/31/94 12 70 N/A 4.7 5.0 4410 4150 4280 4446 4243 260 24 10/31/94 12 54 70 5.0 6.0 4420 4270 4345 4442 4107 25 10/31/94 12 58 71 5.0 5.8 4390 4360 4375 4439 4333 30 26 10/31/94 12 64 72 4.7 5.§ 5010 5120 5065 4463 4595 110 27 10/31/94 12 66 73 5.0 5.5 4800 4720 4760 4474 4733 80 28 11/01/94 25 68 70 4.7 6.0 4810 4940 4875 4488 4900 130 29 11/01/94 25 71 72 5.0 5.5 4820 4690 4755 4498 4797 130 30 11/04/94 31 76 79 3.7 4.5 4090 4060 4075 4484 4568 30 *** Averaqes *** 71 83 4.7 5.1 COMMENTARY OF STATISTICAL EVALUATION OF CONCRETE DESIGN RESULTS Mix No. £8272 Strength 3000 psi @ 28 Days Paragraph 5.5 of ACI 318-89 provides that as data becomes available during construction, the amount by which (f'cr) must exceed the specified value of {f'c) may be reduced, provided: (a) 30 or more test results are available and average of test results exceeds that required by Section 5.3.2.1, using a standard deviation calculated in accordance with Section 5.3.1.1, or (b) 15 to 29 test results are available and average of test results exceeds that required by Section 5.3.2.1, using a standard deviation calculated in accordance with Section 5.3.1.2. The required average compressive strength has been calculated using a standard deviation calculated in accordance with ACI 318-89 Section 5.3.1.1 or Section 5.3.1.2 and is the larger value of these calculations f, = + 1.34(SD) cr f'c = 3000 + 1.34(00531) = 3712 f'cr: f'c + 2.33(SD) - 500 = 3000 + 2.33(00531) - 500 3737 SUMMARY OF STATISTICAL ANALYSIS 28 Day Test Data Number of Tests .......................... 30 Maximum Value ............................ 5935 psi Minimum Value ............................ 3695 psi Range .................................... 2240 psi Average Strength ......................... 44B4 psi Standard Deviation ....................... 531 psi Required Average Strength to satisfy minimum probability conditions of ACI 318-8g Section 5.3.2.1 ............... 3737 psi Design excess beyond code requirements.. 747 psi · ' CEMENT DIVISION, 245 Ward Road Midlothian, Texas 76065 SPECIFICATIONS Portland Cement Type IIII (Low Alkali) A,S,T,M, C150-92 A,A,S,H,T,O, M 85-91 Number 1994 Monthl CHEMiCAE REQUI ilica Oxide, Minimum Percent mina Oxide, Maximum Percent Maximum Percent Maximum Percent SO3 (C3A less than 8%), Maximum Percent Loss on ignition, Maximum Perce.nt 4uble residue, Maximum P..__ercent :ium Aluminate, Maximum Percent Tricalcium Silicate, Maximum Percent Total Alkalies, Max. % (Na20 equi SPECIFICATIONS TEST ASTM RESULTS : :. 20,0 20.0 20,5 6,0 6,0 5 6,0 6,0 .. 4 6.0 6.0 0.9 · * 3.5 3.0 3.C 1.3 0.75 0.75 0.12 8 8 7 55 57 cific sudace, Wagner ~-pecific sudace, Blaine Gillmore, Initial Set, Minimum Gillmore, Final Set, Maximu~m ~ :Vicat, ~itial Set Ai._~r Content, Volume Maximu Autoclave Expansion, Maxi Day Minimum Compress Day____Minimum Compress' ;TATE OF TEXAS ~EMICAI~ REQ 0,60 0.60 0.5 Minimum (M*2/Kg) 160 160 Maximum (M^2/Kg) i.., ~. · :. ' 220 Minimum (M^2/Kg) 280 280 ~.~;: ::::: 400 Maximum (M ^2./Kg) (Minutes) 60 60.__~.__ - 600 600 (Minutes) ~ ~ (Minutes) 45 45 1Maximum (Minutes) 375 375 m Percent 12 12 Jm Percent 0.80 0.80 Strength, PSI 180'-----'~- ~ "------'--' - 2800 Rtrenoth, PSI 2800 J.R. Owens , being duly sworn deposes and says; that he is Chief Chemist of Texas industries, Inc., Cement Division, who prepared the above report of tests and that the same is true and correct. Subscr~ed and sworn to before me this 14th day of October, 1994. Notary Public Ch~ Chemist 192 325 176 301 113 6 0 3470 4349 ELLIS COUNTY *~ ARTM C150 Table 1, Footnote B. October 24, 1994 Construction Products Division W. R. Grace & Co.- Conn. P.O. Box 2585 Houston, TX 77252 (713) 223-8353 TXI 7610 Stemmons Dallas, TX 75247 Gentlemen: This is to certify that WRDA with HYCOL, a water-reducing admixture, as manufactured and supplied by the Construction Products Division, W.R. Grace & Co.-Conn., is formulated to comply with Specifications for Chemical Admixtures for Concrete, ASTM Designation: C-494, Type A (AASHTO M194, Type A). No chlorides or halogens are added to WRDA with HYCOL as functional ingredients during manufacture. Material supplied for the above referenced project is identical in all respects, including concentration, to the one originally submitted to and approved by the State of Texas, Dept. of Transportation. The above is in addition to and not in substitution for our standard Conditions of Sale printed on the reverse side hereof. Tom C. Henson District Manager Subscribed and sworn to, before me, this 24th day of October, 1994 A.D. Not~aryu~ ~b llc We hope the information given here will be helpful. II is based On OUr be$~ knowledge, and we believe it to be true and o¢¢urate. Please read all stotements, recommendations or suggestions herein in conjunction with our conditions of sale which opply to all goods supplied by us. 'We a~ume no responsibility for the use of these statemenls, recommendations, or suggestions, nor do we intend them as a recommendol~on for any use which would infringe ony patent or copyrighl. October 24, 1994 Construction Products Division W. R. Grace & Co. Conn. P.O. Box 2585 Houston, TX 77252 (713) 223-8353 TXI 7610 Stemmons Dallas, TX 75247 Gentlemen: This is to certify that DARATARD-17, a water-reducing set- retarding admixture, supplied by the Construction Products Division, W.R. Grace & Co.-Conn., is formulated to comply with Specifications for Chemical Admixtures for Concrete, ASTM Designation: C-494, as a Type B & D admixture; and the Standard Specifications of the Texas Highway Department. No chlorides or halogens are added to DARATARD-17 as functional ingredients during manufacture. Material supplied for the above referenced project is identical in all respects, including concentration, to the one originally submitted to and approved by the State of Texas, Dept. of Transportation. The above is in addition to and not in substitution for our standard Conditions of Sale printed on the reverse side hereof. Tom C. Henson District Manager Subscribed and sworn to, before me, this 24th day of October, 1994 A.D. We hope the information given here will be helpfuh II is based on our best knowledge, and we believe it to be true and occurate. Please read all statemenls, recommendations or suggestions herein ~r~ conjunction with our conditions of sele which opply to all goods supplied by us. We a~ume no responsibility for the use of lhese statemenls, recommendations, or suggestions, nor do we in~end Ihem os o recommendation for any use which would infringe any patent or copyright. October 24, 1994 Construction Products Division W. R. Grace & Co.- Conn. P.O. Box 2585 Houston, TX 77252 (713) 223-8353 TXI 7610 Stemmons Dallas, TX 75247 Gentlemen: This is to certify that DAREX II AEA, an air-entraining admixture, supplied by the Construction Products Division, W.R. Grace & Co.-Conn., is formulated to comply with Specification for Air-Entraining Admixtures for Concrete, ASTM Designation: C-260 (AASHTO M 154). DAREX II AEA does not contain calcium chloride or chloride containing compounds as a functional ingredient. Chloride ions may be present in trace amounts contributed from the domestic water supply used during the manufacturing process. The above is in addition to and not in substitution for our standard Conditions of Sale printed on the reverse side hereof. ely, Tom C. Henson District Manager Subscribed and sworn to, before me, this 24th day of October, 1994 A.D. Notary~ic J Notary Public, Stale of Texas :[ My Commission Expires 10-20-97 We hope the information given here will be helpful. I~ is based on our best knowledge, and we believe it to be Irue and accurate. Please read all statements, recommendations or suggeslions herein in conjuncllon with our conditions of s~le which apply Io oil goods suppfied by us. We assume no responsibility for the use of these statemenls, recommendations, or suggesllons, nor do we intend them as a recommendation for any use which would infringe any patent or copyright, TEXAS INDUSTRIES, INC. QUALITY CONTROL DEPT. AGGREGATE SIEVE ANALYSIS Date: 12/01/94 #ALL Tests Production Facility: BRIDGEPORT Size #: 57 Grading Designation: ASTM C-33 1" - #4 Project: ***** ALL JOBS ***** Sample Location: Sieve Cumulative Cumulative Cumulative Required Specificatiol Size Wt. Retai)led % Retained % Passino % Retained % Passin~ 1.0" 1.65 98.35 0 - 5 95 - lOI 3/4" 17.31 82.69 1/2" 55,48 44.52 40- 75 25- 3/8" 79,41 20.59 #4 97.27 2.73 90 - 100 0 - #8 98,80 1.20 95 - 100 0 - ' #10 #30 #40 #5o #100 #200 · Pan Wt. Sampled By: Tested By: 100% of 146 tests: Size 57 Plant: BRIDGEPORT Job: ***** ALL JOBS ***** TEXAS INDUSTRIES, INC. QUALITY CONTROL DEPT. AGGREGATE SIEVE ANALYSIS Date: 10/26/94 #ALL Tests Production Facility: PARADISE Size #: Grading Designation: ASTM C-33 FINE AGG. Project: ***** ALL JOBS ***** Sample Location: Sieve Cumulative Cumulative Cumulative Required Specificatio) Size Wt. Retained % Retained % Passina % Retained % Passim 2.0" 3/4" 1/2" 3/8" #4 ~,85 98.15 0- 5 95 - #8 19.05 80.95 0 - 20 80 - 10~ #10 #16 35.0~ 64.99 15 - 50 50 - 8! #30 49.82 50.18 40 - 75 25 - 61 #40 #50 72.16 27.84 70 - 90 10 - 31 #100 95.1] 4.89 90 - 98 2 - #200 98.86 1.14 Pan Wt. 2.73 Fineness Modulus M.C. 6.1% Sampled By: Decant 1.05% S.E. 85.47 Tested By: 100% of 153 tests: Size 33 Plant: PARADISE Job: ***** ALL JOBS *****