DR9306-SP 950427
817 58g ~094 CONCRETE MIX DESIGN CLIENT : PROJECT : LOCATION : DATE: 5/17/~4 DESIGN SPECIFICATIONS: 3000 PSI 50/50 pump 28 Day Strength: Cement Content Fly Ash Content Slump Aggregate Size 3000 psi 9.5 sa~k(equiv.) 20.0 % 6 inch(max.) 1"-{4 cru~he~ Stone AST~ C494 Type A e~ D AST~ C260 3-5 ~ MATERIALS: Oat Cubic Yard Cement ASTH C150 ~iy A~h ASTH C618 Fine Aggregate Water A~m~xture ASTM C494 Aflmtxtute ASTH C~60 PLEASE NOTE ABS.VOLUNE 414 lbs. 2.106 123 lbs. 0.730 1550 lbs. 9.444 1541 · lbs. 9.502 31.0' gals 4.138 16.0, o~/yd 3.00 oz/ya 29.000 ASTH C94 Standard 8peci£icatlons fO: Ready Hix Concrete sta~ as reverts.. The individual who samples and tests concrete must be Ce:tifie~ ACT Level I.a To assist in the ~uallty con,re1 an~ quality Sate REDI-MIX, Inc. GENERAL OFFICE/~ 44.5 M,c:A;,I. hu, Drive. su~t= ! 3~,, carro[I;~.~o Te~,~ 750Q7 PHONI;~ (2141 242-4~0 ; AX; (;' ! 4.1 323-07r~9 TOTrlL P.01