Petterson Addn-CS040401DEVELOPMENT REVIEW COMMITTEE
ENGINEERING COMMENTS
ITEM:
Petterson Addition, Lots 1-4~ Block A~ Replat of Lots 1 and 2, to allow
the construction of four single-family homes on 2.27 acres of property
located along the north side of Sandy Lake Road, approximately 120 feet
west of Summer Place Drive, at the request of Walter Nelson and
Associates.
STAFF REP.: Matt Steer PROJECT ID//RP-03-0091
DRC DA TE: March 25, 2004 and April 1, 2004
CONTACT: Ken Gri~n, P.E., Dir. o/En~ineerin~ & Public Works (972)304-3686
COMMENT STATUS: ,gR=gtarMIC64R~ ,/FINAL RE .....
1. Construct a manhole at the tie-in of the force main to the existing sewer line.
2. Provide preliminary drainage plans for engineering review.
3. No parking is allowed within the fire lane. Provide on-site parking for guests.
4. Provide additional easements, as required, to provide for franchise utilities.
5. A 6" line is inadequate, this shall be an 8" line extending onto Lot 4, and the tap should be
made on the lot.
6. No drainage information was provided, so no comments can be brought forth at this time
conceming drainage; however, please be aware that there have been some ongoing drainage
concerns from the Summerplace Addition to the east and north.
7. The proposed force main is a private utility and will need to be maintained by the property
owners, via some type of property owner association. Also, the concept of a force main and
the ongoing maintenance associated with that could be a problem. Please provide information
on the existing sewer line in Sandy Lake Road and also please evaluate the opportunity to
gain sewer access via the existing 8" sanitary sewer stubbed out from Cottonwood Lane on
the north side of Lot 14. Prior to the approval of the rome main concept, both of these
alternatives will need to be ruled out as viable options by the Engineering Department.
8. The 24' fire lane, utility and access easement should be expanded at the proposed water
meters to ensure that all fire hydrants and water meters are within a utility easement. No
open cutting in Sandy Lake Road will be allowed for a connection of the proposed water line.
DEVELOPMENT REVIEW COMMITTEE
ENGINEERING COMMENTS
ITEM:
PD-200-SF-12~ Petterson Addition~ Lots 1-4~ Block A, zoning change
request from 2F-9 (Two Family-9) to PD-200-SF-12 (Planned
Development-200, Single Family-12) to allow the construction of four
single-family homes on 2.27 acres of property located along the north
side of Sandy Lake Road, approximately 120 feet west of Summer Place
Drive, at the request of Walter Nelson and Associates.
STAFF REP.: Matt Steer PROJECT ID//PD-03-0090
DRC D/I TE: March 25, 2004 and.4pril l, 2004
CONT/ICT: Ken Gri~n, P.E., Dir. o[En~ineerin~ & PubUc }Forks (972)304-3686
COMMENT STA TUS: ] ~Of~gI~lNdag~ ~ FIN/IL P~!q£ED
I
See comments on replat Project ID # RP-03-0091.