Loading...
Securelock-LR040412 GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS DALLAS FORT WORTH HOUSTON AUSTIN LONGVIEW 2400GravelDrive, Bldg 25FortWorth, Texas 76118 phone:(817) 284-9363 fax:(817) 284-9430 In-Place Soil Moisture/Density Tests by Nuclear Method Client: Project: Prime Construction SecurLock Self Storage Coppell, TX TMI Report No.: FC03-63414-021 Report Date: 04/12/2004 specifications Percent Compaction: +95% min Moisture Content: opt -2% to +3% Curve No. Test Method 6887 ASTM D-698-A Reddish Brown Clayey Sand w/Iron Ore Fragments Report Distribution: (1) Houghton Capital (1) Prime Construction Company (1) City of Coppell (1) City of Coppell ~hn~ i~ Reid, A. ET. Material Reference Cu~. Data ~ ~m Material Description f Moisture % Maximum Dry Density pcf 13.0 117.0 In-Place Test Results Test Elevation Ref. Probe Percent Wet Density Dry Density No or Lift Location Curve Depth Moisture (pcf) (pcf) Select Fill for Building Pad 136.0 1st Lift 50' S, 50' W. of NE Corner of Building "A" 6887 6" 13.1 131.9 116.6 137.0 1st Lift 50' S, 100' W. of NE Corner of Building "A" 6887 6" 11.4 128.6 115.4 138.0 1st Lift 20' S, 70' W. of NE Corner of Building "A" 6887 6" I3.0 128.7 113.9 139.0 Final 100' S, 15' W. of SE Corner of Building "B" 6887 6" 11,4 127.0 114.0 140.0 Final 25' S, 15' W. of SE Corner of Building "C" 6887 6" 11.8 128.1 114.6 141.0 Final 40' S, 20' W of SE Corner of Building "C" 6887 6" 12.4 128.2 114.1 142.0 Final 90' S, 10' W. of SE Corner of Building "C" 6887 6" 13.9 131.0 115.0 143.0 3rd Lift 20' W, 10' N. of SE Corner of Building "D" 6887 6" 15.2 130.1 112.9 144.0 3rd Lift 70' W, 20' N. of SE Corner of Building "D" 6887 6" 16.0 130.4 112.4 145.0 Final 20' W, 10' N. of SE Corner of Building "D" 6887 6" 12.4 128.9 114.7 146.0 Final 70' W, 20' N. of SE Corner of Building "D" 6887 6" 12,0 129.8 115.9 147.0 3rd Lift 30' W, 15' N. of SE Corner of Building "E" 6887 6" 13.7 127.6 112.2 148.0 3rd Lift 65' W, 20' N. of SE Corner of Building "E" 6887 6" 11.9 130.9 117.0 149.0 Final 30' W, 15' N. of SE Corner of Building "E" 6887 6" 13.1 130.5 115.4 150.0 Final 65' W, 20' N. of SE Corner of Building "E" 6887 6" 12.0 130.3 116.3 151,0 Final 20' N, 15' W. of SE Corner of Building "F" 6887 6" 14.0 127.5 111.8 152.0 Final 65' N, 15' E. of SW Corner of Building "F" 153.0 2nd Lift 30' N, 30' W. of SE Corner of Building "1" 154.0 2nd Lift 60' N, 40' W. of SE Corner of Building "1" Test results on this report meet project specification Test Method(s): ASTM D-2922, ASTM D-3017 Gauge: Troxler 6887 6" ~ 130.6 117.1 6887 6" ~ 12.1'~ 128.4 114.5 Gauge SN: 18935 _ Std. 114.9 Std. Moisture Count: 2871 TERRA-MAR, INC. ~ Ro oy~D.~Gastle, S.E.T. Materials Testing Manager Percent Density 99.7 98.6 97.4 97.4 97.9 97.5 98.3 96.5 96.1 98.0 99.1 95.9 100.0 98.6 99.4 95.6 100.1 97.9 The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is stdctly prohibited without the express written consent of TMI. 07 Page I of I