Brighton Manor-LR040416Construction Materials Testing
and Environmental Consulting
10044 Monroe Drive Dallas, Texas 75229 (214) 352-6957
Fax (214) 352-6972 www .texascmt.corn
MOISTURE DENSITY RELATIONSHIP REPORT
Test Report Date: April 16, 2004
Client: ~
Sample Date:
Project: Brighton Manor
Identification: Moisture Density Relationship
Test Procedure: ASTM D698
Project No: 204-0126
Moisture Report No. 1
Test Results:
Method .................................................. A
Optimum Moisture Content .................................. 19.0 percent
Maximum Density ......................................... 103.9 pounds per cubic foot
Rammer Type ............................................. Automatic
Material Description ....................................... Olive Gray Sandy Clay
Material Origin ........................................... Block AG Hood Dr.
Moisture Preparation Procedure .............................. Air Dry
Liquid Limit ............................................. 57
Plastic Limit
Percent Passing No. 200 U.S. Sieve .......................... ~
Technician: AT
Mr. Jim Street - Street Homes
Mr. Larry Davis - City of Coppell
Mr. Rodney Lonviere - Fax: 972-931-6787
Our letters and reports are for the exclusive use of the client m whom they are addressed. The use of our name must receive our prior wrhten approval. Our letters and reports apply
only to the sample tested and/or observed, and are not necessarily indicative of the quant/ties of apparently identical or similar products.
Construction Materials Testing
and Envirommental Consulting
Texas
CMT,
Irlc
10044 Monroe Drive Dallas, Texas 75229 (214) 352-6957
Fax (214) 352-6972 www .texascmt.com
MOISTURE DENSITY RELATIONSHIP REPORT
Test Report Date:
Client:
Sample Date:
Project:
Identification:
Test Procedure:
April 16, 2004
Brighton Manor
April 7, 2004
Brighton Manor
Moisture Density Relationship
ASTM D698
Project No: 204-0126
Moisture Report No. 2
Test Results:
Method .................................................. A
Optimum Moisture Content .................................. 12.8 percent
Maximum Density ......................................... 117.6 pounds per,cubic foot
Rammer Type ............................................. Automatic --
Material Description ....................................... Yellowish Orange Sandy Clay
Material Origin ........................................... Block B, Lot 2
Moisture Preparation Procedure .............................. Air Dry
Liquid Limit ............................................. ~
Plastic Limit ............................................ ~
Plasticity Index ........................................... ~
Percent Passing No. 200 U.S. Sieve ........................... 51
Technician: AT
CC:
Mr, Jim Street - Street Homes
Mr. Larry Davis - City of CoppelI
Mr. Rodney Lonviere - Fax: 972-931-6787
Our Ictters and reports are for thc exclusive use of thc client to whom they are addressed. Thc usc of our name must receive our prior written approval. Our letters and rcports apply
Construction Materials Testing
and Environmental Consulting
Texas
CMT,
Inc.
10044 Monroe Drive Dallas, Texas 75229 (214) 352-6957
Fax (214) 352-6972 www .texascmt.com
MOISTURE DENSITY RELATIONSHIP REPORT
Test Report Date:
Client:
Sample Date:
Project:
Identification:
Test Procedure:
April 16, 2004
Brighton Manor
April 7, 2004
Brighton Manor
Moisture Density Relationship
ASTM D698
Project No: 204-0126
Moisture Report No. 3
Test Results:
Method .................................................. A
Optimum Moisture Content .................................. 24.0 percent
Maximum Density ........................................ .~ 95.8 pounds per cubic foot
Rammer Type ............................................. Automatic
Material Description ....................................... Dark Brown Clay
Material Origin ........................................... Block B, Lot 4
Moisture Preparation Procedure .............................. Air Dry
Liquid Limit ............................................. 62
Plastic Limit ............................................
Plasticity Index ..........................................
Percent Passing No. 200 U.S. Sieve ...........................
Technician: AT
Mr. Jim Street - Street Homes
Mr. Larry Davis - City of Coppell
Mr. Rodney Lonviere - Fax: 972-931-6787
Construction Materials Testing
and Environmental Consulting
Texas
CMT,
II1C,
10044 Monroe Drive Dallas, Texas 75229 (214) 352-6957
Fax (214) 352-6972 www .texascmt.com
MOISTURE DENSITY RELATIONSHIP REPORT
Test Report Date:
Client:
Sample Date:
Project:
Identification:
Test Procedure:
April 16, 2004
Brighton Manor
April 7, 2004
Brighton Manor
Moisture Density Relationship
ASTM D698
Project NO: 204-0126
Moisture Report No. 4
Test Results:
Method .................................................. A
Optimum Moisture Content .................................. 24.0 percent
Maximum Density ........................................ ~93.9 pounds per cubic foot,
Rammer Type ............................................. Automatic
Material Description ....................................... Light Brown Clay
Material Origin ........................................... Duncan Drive, between Block B,
......................................................... Lot 10 and Block C, Lot 6
Moisture Preparation Procedure .............................. Air Dry
Liquid Limit ............................................. 81
Plastic Limit ............................................ ~
Plasticity Index ..........................................
Percent Passing No. 200 U.S. Sieve ...........................
Technician: AT
Mr. Jim Street - Street Homes
Mr. Larry Davis - City of Coppell
Mr. Rodney Lonviere - Fax: 972-931-6787
only to the sample tested and/or observed, and are not necessarily indicative of the quantities o f apparently identical or similar products.
Construction Materials Testing
and EnvirorLrnental Consulting
Texas
CM%
10044 Monroe Drive Dallas, Texas 75229 (214) 352-6957
Fax (214) 352-6972 www .texascmt.com
MOISTURE DENSITY RELATIONSHIP REPORT
Test Report Date:
Client:
Sample Date:
Project:
Identification:
Test Procedure:
April 16, 2004
Brighton Manor
April 7, 2004
Brighton Manor
Moisture Density Relationship
ASTM D698
Project No: 204-0126
Moisture Report No. 5
Test Results:
Method .................................................. A
Optimum Moisture Content .................................. 11.3 percent
Maximum Density ......................................... 120.2 pounds per cubic foot
Rammer Type ............................................. Automatic
Material Description ....................................... Yellowish Orange Clayey Sand
Material Origin ........................................... Block C, Lot 2
Moisture Preparation Procedure .............................. Air Dry
Liquid Limit ............................................. 18
Plastic Limit ............................................. 12
Plasticity Index ........................................... 6
Percent Passing No. 200 U.S. Sieve ........................... 30
Technician: AT
Mr. Jim Street - Street Homes
Mr. Larry Davis - City of Coppell
Mr. Rodney Lonviere - Fax: 972-931-6787