Sandy Lk Cross 2R-CS040429DE VEL OPMENT RE VIE W COMMITTEE
ENGINEERING COMMENTS
ITEM:
Sandy Lake Crossing Addition, Lot 2R, Block Ir Replat, being a
replat of Lot 2, Block 1 of the Sandy Lake Crossing Addition, to allow the
construction of an approximate 7,200-square-foot retail building on 0.737
of an acre of property located along the south side of Sandy Lake Road,
approximately 200 feet west of Denton Tap Road, at the request of
Thomas J. Whan, Creekside Construction Ltd.
STAFF REP.: Marcie Diamond PROJECT ID//RP-04-0024
DRC DA TE: April 29, 2004 and May 6,2004
CONTACT: Kenneth ~. Grifdm,~ PE,. . Dir. o(Engineering/Public Works 972/304-3686
COMMENT STATUS: ,/PRELIMINARY F!A~L REVISED
AFTER P&Z
Plat -
1. Provide 5' sidewalk/utility easement adjacent to north property line.
Utilities Plan -
1. We need a fire hydrant onsite with location to be specified by the Fire Marshal.
2. Domestic and irrigation services need to be off the main waterline, not the fire line, with
meters located in the public right-of-way or a utility easement.
3. A fire vault is needed on the fire line with a double detector check inside the vault.
4. I recommend an 8" waterline with a 6" branch to a hydrant onsite and a 6" branch to the
building for sprinkler purposes.
5. An FDC connection should be made within 50' of the fire hydrant.
6. The drive~vay connection to Sandy Lake Road needs to be reconstructed with concrete; it is in
substandard condition.
Additional comments may be generated and a need for additional easements may be identified as
a result of a detailed engineering review.
DEVELOPMENT REVIEW COMMITTEE
ENGINEERING COMMENTS
ITEM:
Sandy Lake Crossing Addition~ Lot 2R, Block 1~ Site Plan~ to allow
the construction of an approximate 7,200-square-foot retail building on
0.737 of an acre of property located along the south side of Sandy Lake
Road, approximately 200 feet west of Denton Tap Road, at the request of
Thomas J. Whan, Creekside Construction Ltd.
STAFF REP.: Marcie Diamond PROJECT ID# SPA-04-0023
DRC DA TE: April 29, 2004 and May 6,2004
CONTACT: Kenneth M. Griffin, P.E., Dir. o~Engineering/Public Works 972/304-3686
COMMENT STATUS: '/PRELIMINARY ~rnr A r ~ ~ ~;r c ~ r~
~ ~T~o P&Z
See next case (replat) for additional site plan comments.