Brighton Manor-CS040518May 18, 2004 T H E · C I T Y 0 F COPPELL Scott Caruthers, P.E. Dowdey, Anderson & Associates, Inc. 5225 Village Creek Drive, Suite 200 Plano, TX 75093 RE: Brighton Manor (Falls at Westmont) Dear Mr. Caruthers: The detail of information on recently received geotechnical reports from Texas CMT makes it impossible to ascertain the location(s) from which sample materials were taken for analysis (see attached reports). There is no information related to the size of material, whether the location was a utility line or what depth the material tested was from. Please refer to the City of Coppell Standard Construction Details and Subdivision Ordinance. The City of Coppell requests a site visit to verify questionable materials in which water, sanitary sewer and storm drain lines have been placed, and to verify that densities in all trench lines meet City of Coppell minimum standards. If you have any questions, please contact me at (972) 304-3684. Office: 972/304-3684 Fax: 972/0304-3570 CC: Ken Griffin, P.E., Director of Engineering & Public Works Richard Gee, P.E., Texas CMT Keith Marvin, P.E., Civil Engineer Rodney Louviere, Dowdey, Anderson & Associates Construction Materials Testing and Environmental Consulting Tex s CM% ID.C 10044 Monroe Drive Dallas, Texas 75229 (214) 352-6957 Fax (214) 352-6972 www .texascrnt.com GENERAL REPORT Report Date Client Project April 26, 2004 Street Custom Homes Brighton Manor Test Date: April 23, 2004 General Report No.: 1 Project No.: 204-0126 Texas CMT technician was present on April 26, 2004 to observe trench backfill operations. The folloWing oUtstanding observations were noted: ~ ~ : 1. C. Con Cooper was backfilling with Light Gray Shale & Dark Gray Shale in chunks up to 24"x12"x6" in water main line and water crossing. 2. There was no bedding material under the water line crossing. Line was laying on large chunks of Dark Gray Shale. 3. Per COG specs, we recommended no rock fragments larger than six (6) inches be utilized as utility trench backfill. Shale chunks should be mixed with enough fines to prevent voids. Technician: DF Mr Jim Street - Street Custom Homes M/ Lasry Davis - City of Coppell Mr. Rodney Louviere - Fax: 972-931-6787 Construction Materials Testing and Environmental Consulting Texas CMT, IB.C. 10044 Monroe Drive Dallas, Texas 75229 (214) 352-6957 Fax (214) 352-6972 www .texascrat.com GENERAL REPORT Report Date May 13, 2004 Client S~reet Custom Homes Project Brighton Manor Test Date: May 4, 2004 General Report No.: 3 Project No.: 204-0126 At the request of Mr. Rodney Louviere, a Texas CMT technician was present on May 4, 2004 to perform in-place densities and observe gray shale backfill for utility trenches. The following observations were made: -~1. Gray shale fragments in general were according to COG specifications, no larger than six .(6) inches. ,~2. Shale fragments were mixed with enough fines (no voids observed). ,--~3. In-place densities taken met project compaction and moisture content specificat~ns. Technician: AB Mr [~W Davis - City of Coppell Mr Rodney Louvierc - Fax: 972-931-6787