Loading...
Magnolia Village-LR010907ALPHA TESTING, INC. 2209 Wisconsin St., Suite 10 Dallas, Texas 75229 (972) 620-8911 Concrete Compression Test Report Tested For: CONSTRUCTION MANAGEMENT GROUP ATTN: MR. JEFF MILLER 5207 MCKINNEY AVENUE, SUITE 12 DALLAS, TX 75205 Fax Number: (214)521-1279 Project Desc: MAGNOLIA RETAL 651 S. DENTON TAPP- COPPELL, TX Our Report No.: 01614-9 Issue Date: 09/07/2001 FIELD DA TA Placement Location: MANHOLE, LINE A ~ STATION 0+00 Date Place~l: 8/8/01 Time Placed: 2:20 PM Slump (Afl;TM C-t4~): 3.5 Air Content: N/A Air Temperature: 92 Specimen Temperature: 90 Date Received: 8/9/01 Delivery Method: PICKED UP BY ALPHA Field Date Submitted By:. PACHECO, JAMES Mix Date Submitted By: LMC Plant Number: 7-6.0 SK Delivery Ticket No.: 7106242 Made By:. ALPHA Cured Speclflcetlon: ASTM C-31 CYLINDER COMPRESSION TEST RESUL TS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: T~: Spec: Teated: ~Da~): Length Width Diameter Sq. In. Load: PSI: LAB C-1231 8/15/01 7 12 N/A 6 28.27 113863 4020 2 LAB C-1231 9/5/01 28 12 N/A 6 28,27 143530 507~ 3 LAB C-1231 9/5/01 28 12 N/A 6 28.27 146705 5180 4 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 4000 Resulte to Date: PASS Respectfully Submitted By: ~ ~ of Alpha Testing, inc. Our te~t re~l~ and repore are for the excludve u~ ~f't~C~n, ( da d~thelr (left.areal r~n:epleno, i.de. our office, and shall no~ be .produ.d an.or .~allnned ex. pt