ST0102-LR030328Ro gineers 1t~08 Ambassador Row Dallas, Texas 7524%4510 (214) 630-9745 (214) 630-9819 (fax) IN-PLACE DENSITY TESTING Client: City of Coppell Atto: Ms. Suzan Taylor PO Box 478 Coppell TX 75019 Project: Ruby Road (ST 01-02) Coppell, TX Report No.: 173440 Project No.: 027176 Date of Service: 03/25/2003 Report Date: 03/28/2003 Services: Perform In-Place Density Test in accordance with ASTM Standards. PROJECT DATA CONTRACTOR: Tiseo Paving Test Methods: ASTM D-2922 ASTM D-3017 M/D No. Description Gauge: Troxler 3430 Moisture Gauge Serial No: 32685 Current: 645 Test Mode: DT Previous: 648 MOISTURE DENSITY RELATIONS Standard Counts Density Current: 2945 Previous: 3013 Project Requirements Moisture Density Dark Brown Sandy Clay (lime treated) 29.0 90.0 Optimum +4 95 min FIELD DENSITY TESTS TEST NO TEST LOCATION PROBE DEPTH M/D MOISTURE WET DENSITY DRY DENSITY DENSITY No. (%) (pcf) (pc0 (% max) Paving Subgrade Ruby Road, Station 2+00, left of centerline Paving Subgrade 2 Ruby Road, Station 3+00, centerline Paving Subgrade 3 Ruby Road, Station 4+00, right of centerline Paving Subgrade 4 Ruby Road, Station 5+00, centerline Paving Subgrade 5 Ruby Road, Station 6+00, left of centerline Paving Subgrade 6 6" 1 32.6 115.8 87.3 97 6" I 31.4 117.1 89.1 99 6" 1 32.1 114.4 86.6 96 6" 1 32.8 115.3 86.8 96 6" 1 29.9 117.6 90.5 101 114,3 87.6 97 Ruby Road, Station 7+00, centerline 6" 1 30.5 Test results on this report meet project specification. Technician: Joe Jernigan Report Distribution: (I) City of Coppell (I) Tiseo Paving Company (I) Pacheco Koch (1) Wdght Construction Company Started: 3:30pm John Moody Project Manager Ltd. LIMITATKJNS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality Icomposition. appearance, perfom~ance, utc ) or any other feature of similar subject matter provided by persons or conditions over which we have no control Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Roue Engineers, Lld 07DD Page I of 1