IN-PLACE DENSITY TESTING
Client:
City of Coppell
Attn: Ms. Suzan Taylor
PO Box 478
Coppell TX 75019
Project: Ruby Road (ST 01-02)
Coppell, TX
Report No.: 168813
Project No.: 027176
Date of Service: 01/16/2003
Report Date: 02/04/2003
Services: Perform In-Place Density Test in accordance with ASTM Standards.
PROJECT DATA
CONTRACTOR: q,'i~;eo Paving
Test Methods: ASTM D-2922
ASTM D-3017
Standard Counts
Gauge: Troxler 3430 Moisture Density
Gauge Serial No: 24324 Current: 550 Current: 2283
Test Mode: DT Previnus: 581 Previous: 2285
MOISTURE DENSITY RELATIONS
Maximum Project Requiremeuts
M/D No. Description Moisture % Density pcf Moistm'e Density
1 Medium Brown Sandy Clay w/Gravel 15.5 112.0 Optimum +4 95 mtn
2 Dark Brown Clay w/Traces of Gravel
21.5 102.0 Optimum +4 95 mtn
FIELD DENSITY TESTS
TEST PROBE
NO TEST LOCATION DEPTH
M/D MOIS'IURE WET DENSITY DRY DENSITY DENSITY
No. (%) (pcf} (pcO (% max)
General Fill
i Station 11+00, south right-of-way, 7' below 6" 2 23.5 124.9 101.1 99
grade
General Fill
2 Station 11+25, north right-of-way, 8' below 6" 2 22.2 127.9 104.7 103
grade
General Fill
3 Station 10--50, north right-of-way, 6' below 6" 1 18.5 127.6 107.7 96
grade
Test results on this report meet project specification.
Density tests over 102% may be due to over compaction.