ST0102-LR021224RoneEngineers 8908 Arubassador Row Dallas, Texas 75247-4510 {214) 630-9745 (214) 630-9819 (fax) IN-PLACE DENSITY TESTING Client: City of Coppell Attn: Ms. Suzan Taylor PO Box 478 Coppell TX 75019 Project: Ruby Road (ST 01-02) Coppell, TX Report No.: 166893 Project No.: 027176 DateofServiee: 12/20/2002 Report Date: 12/24/2002 Services: Perform In-Place Density Test in accordance with ASTM Standards. PROJECT DATA CONTRACTOR: Tiseo Paving Test Methods: ASTM D-2922 ASTM D-3017 M/DNo. Description Gauge: Troxler 3430 Moisture Gauge Serial No: 32685 Current: 647 Test Mode: DT Previous: 644 MOISTURE DENSITY RELATIONS Maximum Moisture % Density pcf Standard Counts Density Current: 2982 Previous: 3035 Project Requirements Moisture Density Medium brown sandy clay w/gravel 15.5 112.0 Optimum +5 95 rain FIEI,D DENSITY TESTS TEST NO TEST LOCATION PROBE M/D MOISTURE WET DENSITY DRY DENSITY DENSITY DEPTH No. (%) (pc0 (pc0 (% max) Utility Backfill Sanitary sewer line I, Ruby Road, station 3+50, 7' below grade Utility Backfill 2 Sanitary sewer line I, Ruby Road, station 3+50, 3' below grade Utility Backfill 3 Sanitary sewer line I, Ruby Road, east of manhole, station 4+00, 6' below grade Utility Backfill 4 Sanitary sewer line I, Ruby Road, west of manhole, station 4+00, 4' below grade Technician: Joe Jernigan Report Distribution: (1) City of Coppell (1) Tiseo Paving Company (1) Pacheco Koch (1) Wright Construction Company 6" 1 19.3 134.3 112.6 101 6" I 18.6 131.0 110.5 99 6" 1 17.8 126.5 107.4 96 6" I 17.8 127.0 107.8 96 Test results on this report meet project specification. ~ ]~ Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the excfasive use of thc clients to whom they are addressed and shall not be reproduced except in fall without the written approval o£Rone Engineers, Inc. 07DF Page 1 of 1 Ro gineers 8908 Ambassador Row Dallas, Texas 752474510 (214) 630-9745 (214) 630-9819 (fax) IN-PLACE DENSITY TESTING Client: City of Coppell Attn: Ms. Suzan Taylor PO Box 478 Coppell TX 75019 Project: Ruby Road (ST 01-02) Coppell, TX Report No.: 166876 Project No.: 027176 Date of Service: 12/20/2002 Report Date: 12/24/2002 Services: Perform In-PEace Density Test in accordance with ASTM Standards. PROJECT DATA CONTRACTOR: Tiseo Paving Test Methods: ASTM D-2922 ASTM D-3017 Gauge: Troxler 3430 Gauge Serial No: 32685 Test Mode: DT Moisture Current: 647 Previous: 644 Standard Counts Density Current: 2982 Previous: 3035 M/D No. Description MOISTURE DENSITY RELATIONS Maximum Moisture % Density per Medium brown sandy clay w/gravel Project Requirements Moisture Density 15.5 112.0 Optimum +5 95 min FIELD DENSITY TESTS TEST NO TEST LOCATION PROBE DEPTH M/D MOISTURE WET DENSITY DRY DENSITY DENSITY No. (%) (pcf) (pc0 (% max) Utility Backfill Sanitary sewer line l, Ruby Road, station 1 +00, 6' below grade Utility Backfill 2 Sanitary sewer line I, Ruby Road, station 1 +00, 3' below grade Utility Backfill 3 Sanitary sewer line I, Ruby Road, station 2+15, 3' below grade Utility Backfill 4 Sanitary sewer line I, Ruby Road, station 2+60, 6' below grade Technician: Joe Jernigan Report Distribution: (1) City of Coppell (1) Tiseo Paving Company (1) Pacheco Koch (1) Wright Construction Company 6" 1 16.7 124.8 106.9 95 6" 1 19.7 128.2 107.1 96 6" 1 15.9 125.2 108.0 96 6" 1 17.3 125.3 106.8 95 Started: 9:30AM Finished: ll:30A ~_ ~ ~,~ Project Manage/~' ~lohn Moodyr LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, inc. 07DF Page 1 of 1