Loading...
SS9901-SP040614Turner Collie ( Braden Inc. To: From: Date: Job No.: Subject: See Distribution George Cisneros, P.E. - TCB June 14, 2004 052 131124.0001 04000.A123 (2.1) JOB#1 . DATE T--R:9 SMITTAL AHL PJS Deforest and Sandy Lake Wastewater Lift Stations and Force Main Improvements Force Main Lines A&B Shop Drawing Review Comments Submittal No. 1 TCB has the following comments on this submittal: Description Status Comment Storm Water Pollution Received ~ Prevent Plan Trench Safety Received N Oh: Plan/Specifications ~- Traffic Control Plan Received f Type B-2 Embedment No Exceptions Taken Type C Embedment No Exceptions Taken HDPE Pipe & Fittings Make Corrections Noted; HDPE to be D.I.P.S; Per Specification Submit Specified Items Section 02643, HDPE fittings cut sheets shall be submitted; HDPE Fusion Water No Exceptions Taken Qualifications HDPE Driller No Exceptions Taken Experience Record 8 Mil Polyethylene Pipe No Exceptions Taken Wrap SDR 26 PVC No Exceptions Taken Gate Valves No Exceptions Taken D.I. Fittings Make Corrections Noted Clarify Meglug retainer glands are to be used for this project, not Tyler retainer glands; Precast Manholes Make Corrections Noted There are no flat top manholes in this project; use regular type manhole reducing cone; MH pipe to manhole Rejected Contractor to install Kor-n-seal boot connector assembly; MH Rubber Gasket for Rejected Manhole section joints to be sealed with Section Joints Ramnek strips; Lifting bodies with No Exceptions Taken eyelinks or chains Concrete Mix Design No Exceptions Taken (mortar) Line A&B 06/14/04 Page 2 Manhole Ring & Cover No Exceptions Taken Casing Spacers No Exceptions Taken Combination Sewage No Exceptions Taken Per the fax received by TCB on June 9, Air Valve 2004 by Jim Cox Sales, Inc., it is understood ARI D-020 combination air valves will be used for this project; Flange Bolt & Gasket No Exceptions Taken Set Megalug Retainer No Exceptions Taken Gland Detectable Tape Revise and resubmit Per General Notes, detector tape shall state in a minimum of 1 ½" letters "Pressur/zed Wastewater" continuously along the tape; D.I. Pipe Submit Specified Item When you re-submit the shop drawings, please address all comments and submit six (6) copies to this office. Distribution: [X] 2 copies of submittal to the City [X] 3 copies of submittal to C.J. Louis Construction of Texas IX] 1 copy of submittal to TCB file [ ] Other