SS9901-SP040512~ ~S. J Louis Construction of Texas, Ltd. P.O. Box 834 Mansfield, Texas 76063 (817) 477-0320 Office (817) 477-0552 Fax TO: Turner Collie & Braden, Inc. 17300 Dallas Parkway, Suite 1010 Dallas, Texas 75248 972-735-3000 LETTER OF TRANSMITTAL Date: Ma), 12, 2004 Attn: Ted B. Sugg Deforest Rd. Lift Station Improvements RE: Force Main Lines A & B Project No. SS 99-01 WE ARE SENDING YOU: [] ATTACHED [] SHOP DRAWINGS [] LETTER []SUBMITTALS [] PRINTS [] PLANS [] CHANGE ORDER [] SPECIFICATIONS THE FOLLOWING ITEMS: [] SAMPLES ~-]OTHER COPIES DATE NO. DESCRIPTION 6 5/12/04 009 Submittal Data for: 8 MIL POLYp- I HYLENE PIPE WRAP THESE ARE TRANSMITTED AS CHECKED BELOW: []FOR APPROVAL [--]FOR YOUR USE []AS REQUESTED [] FOR REVIEW AND COMMENT REMARKS: []APPROVED AS SUBMITTED []APPROVED AS NOTED []RETURN FOR CORRECTIONSE]RETURN []OTHER E~RESUBMIT E]SUBMIT COPIES FOR APPROVAL COPIES FOR DISTRIB. CORRECTED PRINTS JOB# 14016 DATE 5/12/04 SDM D~ SDM 5/12/04 Mailed 5/12.J04 COPIED ,~"~u-e'l Montoya / ~Project Coordinator S.J. LOUIS CONSTRUCTION OF TEXAS LTD. 520 South 6th Ave., RO. Box 834 Mansfield, Texas 76063 817/477-0320 Office · 817/477-0552 Fax Equal Opportunity Employer / Contractor May 12, 2004 Turner Collie & Braden, Inc. 17300 Dallas Parkway, Suite 1010 Dallas, Texas 75248 Attn: Ted B. Sugg, P.E. Re: Deforest Road Lift Station Improvements Force Main Lines A & B Project No. SS 99-01 Attached is Submittal Data for: 8 MIL POLYETHYLENE PIPE WRAP This material is proposed for use on the above referenced project. Please call me at 817-477-0320 if you have any questions, or require additional information Sincerely, S. J. LOUIS CONSTRUCTION OF TEXAS LTD., LLP Certification Statement: By this submittal, I hereby represent that I have determined and verified all field measurements, field construction criteria, materials, dimensions, catalog numbers and similar data affecting this submittal and I have checked and coordinated this submittal with other applicable approved submittals and Contract requirements." Date: 8 MIL CROSS LAMINATED HIGH DENSITY POLYETHYLENE Page 1 of 3 POLYCASE LINEAR LOW DENSITY POLYETHYLENE ENCASEMENT PRODUCTS BY FULTON 198 WALTER DAVIS DRIVE BIRMINGHAM. A~ABAMA 35209 PHONE 205-942-7504 OR 800-756-6695 - FAX 205-942-0705 EMAIL - info(~fuNoninc.com 8 MIL LINEAR LOW DENSITY POLYETHYLENE PHYSICAL ATTRIBUTE I ANSI/AWWAC105/A215 I I ViRGINCROSSLAM!NATED I TEST I M,NIMUM POLYCASE DIRECTION REQUIREMENT TYPICAL TEST VALUES 948% 1012% ELONGATION 800% DIELECTRIC STRENGTH iMPACT RESISTANCE 928 ~ram$ !1 ^STMD'0T'~m'IIII THICKNESS I I 5o9~,,m, I I I PROPAGATION TEAR RESISTANCE (?B II MACHINE DIRECT'ON TRANSVERSE D!RECTION I 8 mil STOCK TUBE SIZES BASED ON ANSI/AWWA C105iA21 5-99 SeC, ion 42 I DI RIPE SIZE I DAYFLAT TUBE SIZE I 4" * 6" 15" X 500 FT. ROLL 8" 20" X 500 FT. ROLL 10" 24" X 500 FT ROLL 12" 27" X 500 FT. ROLL 14" 30" X 500 FT. ROLL FOR PRODUCT NOT SHO~ IN OUR STANDARD STOCK TUBE SIZES ~E CAN PROVIDE FILM uESIGNED TO MEET YOUR MOST DEMANDING I http://www, fultoninc.com/fulton 8mil.htm 5/12/2004 8 MIL CROSS LAMINATED HIGH DENSITY POLYETHYLENE Page 2 of 3 18" 37" X 500 FT. ROLL 20" 41" X 500 FT, ROLL 24" 54" X 500 FT. ROLL 30" 67" X 440 FT. ROLL 36" & 42" 81" X 360 FT. ROLL 48" 95" X 220 FT. ROLL 54" & 60" 108" X 220 FT. ROLL $4" 12t" X '110 FT. ROLL SPECIALITY POLYETHYLENE ;]LM =ROPERTiES, MATERIALS,AND METHCDS MAY VARY TO MEET SPECIFIC DESIGN REQUIREMENTS http://www.fultoninc.com/fulton 8mil.htm 5/12/2004 8 MIL CROSS LAMINATED HIGH DENSITY POLYETHYLENE Page 3 of 3 http://www.fultoninc.com/fulton 8mil.htm 5/12/2004