Loading...
Sandy Lk Med-LR040519SPEC'~ RUM GLOeAL LABORATORY SERVICES, LLC. CF Jordan Client: Project: Report No. Technician: 03-1041-85 D, Lewis 45S2 Beitway Drive Addison, Texas 75~01 (469) 916-01~ Fax (469) 916-0101 Report of Concrete Compression Testfn~ Distribution: File Index: CON Specifications Test Data Strength (psi): 3000 Slump (in.): 3-5 Air Content (%): Concrete Temp (°F Ticket #: 213551 Slump (in.): 6 1/2 Concrete Temp (°F): 80 Sample Location: Remams: Placement ,Date: 5/19/04 Weather: Supplier/Mix: Air Content Method: C231/C 173 Set#1 Time Batched: 2:00 Time Sampled: Air Content (%): Unit Weight (pcf): Air Temp. (oF): 85 Yardage (c.y.): Sidewalk along N. side of the building. 3:00 N/A 10of30 SpeclmenlO Tested Age Max Load Area(in2) Streng~ Fract Notes 159 1 5/26 7 88520 28.27 3131 160/, 6/16 28 95820 28.27 3389 161 ,, 6/16 28 95340 28.27 3372 162 H H Respectfully submitted. Spectrum Global Laboratory Services. LLC.