Securelock-LR040817 GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS DALLAS FORT WORTH HOUSTON AUSTIN LONGVIEW 2400 Gravel Drive. Bldg. 25 Fort Worth, Texas 76118 phone: (817) 284-9363 fax:(817) 284-9430 Client: Prime Construction Project: Secur-Lock Self Storage Coppell, Texas TMI Report No.: Report Date: FC03-63414-049 08/17/2OO4 Concrete Compression Test Report Specifications Strength 3500 psi @ 28 Days Slump 3 in min 5 in max Air Content 3 % min 6 % max Concrete Temperature n/a Ambient Temperature n/a Report Distribution: (1) Houghton Capital (1) Prime Construction Company (1) City of Coppe[I (1) City of Coppell (1) AECC Inc. Test Da~a Placement Date 08/09/2004 Sampled By Keith Bowen Weather Cloudy Supplier/Mix So. Star/9339 Air Content Method ASTM C-231-B Ticket Number: 66059 Slump: 4.5 in Concrete Temperature: 89° F Placement Location: Paving Sample Location: Time Batched: 2:06 Time Sampled: 2:30 Air Content: 4.5 % Unit Weight: n/a Ambient Temperature: 80° F Yardage (c.y.): 50 20' S. & 10' E From The N.E, Comer of Building C Age Max Load Area Strength Fracture Set # Cyl~der Test Date (days) (lbs. force) (sq.in.) (psO Type I SLC08090401 08/16/2004 7 1 SLC08090402 08/23/2004 14 1 SLC08090403 09/06/2004 28 1 SL008090404 09/06/2004 28 83974 28.27 2970 Normal cylinder size: 6" x 12" Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143 C172, C1064, and C617 or C1231. TERRA-MAR, INC. Construction Division Manager The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is strictly prohibited without the express wdtten consent of TMI. Page I of 4 GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS DALLAS FORT WORTH HOUSTON AUSTIN LONGVIEW 2400 Gravel Drive, Bldg. 25 Fort Worth, Texas 76'i18 phone: (817) 284-9383 fax:(817) 284-9430 Concrete Compression Test Report Client: Prime Construction Project: Secur-Lock Self Storage Coppell, Texas TMI Report No.: FC03-63414-049 Report Date: 08/17/2004 Report Distribution: (1) Houghton Capital (1) Prime Construction Company (1) City of CoppeH (1) City of Coppell (1) AECC inc. Specifications Strength 3500 psi @ 28 Days Slump 3 in rain 5 in max Air Content 3 % min 6 % max Concrete Temperature n/a Ambient Temperature n/a Test Da'3a Placement Date 08/09/2004 Sampled By Keith Bowen Weather Cloudy Supplier/Mix So. Star/9339 Air Content Method ASTM C-231-B Ticket Number: 660676 Slump: 5 in Concrete Temperature: 90° F Placement Location: Paving Sample Location: Time Batched: 3:51 Time Sampled: 4:45 Air Content: 4.5 % Unit Weight: n/a Ambient Temperature: 76" F Yardage (c,y,): 200 10' N. & 15' E. from The N.W. Corner of Building D Cylinder Set # Cf Age Max Load Area Strength Fracture Test Date (days) (lbs. force) (sq.in.) (ps~ Type 02 SLC08090405 08/16/2004 7 02 SLC08090406 08/23/2004 14 02 SLC08090407 09/06/2004 28 02 SLC08090408 09/06/2004 28 Normal cylinder size: 6" x 12" 88272 28.27 3120 Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or. C1231. TERRA-MAR, INC. Construction Division Manager The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is strictly prohibited without the express written consent of TMI. Pagc 2 of 4 Client: Prime Construction Project: Secur-Lock Self Storage Coppell, Texas GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS DALLAS FORT WORTH HOUSTON AUSTIN LONGVIEW 2400 Gravel Drive, Bldg. 25 Fort Worth, Texas 76118 phone: (817) 284-9363 fax:(817) 284-9430 Concrete Compression Test Report Report Distribution: (1) Houghton Capital (1) Prime Construction Company (1) City of Coppell (1) City of Coppell (1) AECC Inc. TMI Report No.: FC03-63414-049 Report Date: 08/17/2004 Specifications Test DaTa Strength 3500 psi @ 28 Days Placement Date 08/09/2004 Slump 3 in min 5 in max Sampled By Keith Bowen Air Content 3 % min 6 % max Weather Cloudy Concrete Temperature n/a SuppliedMix So. Star/9339 Ambient Temperature n/a Air Content Method ASTM C-231-B Ticket Number: 660687 Slump: 5 in Concrete Temperature: 90° F Sample Location: Time Batched: 5:00 Time Sampled: 6:20 Air Content: 5.0 % Unit Weight: n/a Ambient Temperature: 73° F Yardage (c.y.): 330 25' N. & 5' W. From S.W. Corner of Building F Cylinder Age Max Load Area Strength Fracture Set # # Test Date (days) (lbs. force) (sq.in.) (psi) Type 03 SLC08090409 08/16/2004 7 95935 28.27 3390 03 SLC08090410 08/23/2004 14 03 SLC08090411 09/06/2004 26 03 SLC08090412 09/06/2004 28 Normal cylinder size: 6" x 12" Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or.C1231. TERRA-MAR, INC. Construction Division Manager The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is strictly prohibited without the express written consent of TML Page 3 of 4 GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS DALLAS FORT WORTH HOUSTON AUSTIN LONGVIEW 2400 Gravel Drive Bldg 25 Fort Worth, Texas 76118 phone: (817) 284-9363 fax:(817) 284-9430 Client: Prime Construction Project: Secur~Lock Self Storage Coppell, Texas TMI Report No.: FC03-63414-049 Report Date: 08/17/2004 Specifications Concrete Compression Test Report Report Distribution: (1) Houghton Capitsl (1) Prime Construction Company (1) City of Coppell (1) City of Coppell (1) AECC Inc. Test Da~a Strength 3500 psi @ 28 Days Slump 3 in min 5 in max Air Content 3 % min 6 % max Concrete Temperature n/a Ambient Temperature n/a Placement Date 08/09/2004 Sampled By Keith Bowen Weather Cloudy SuppliedMix So. Stad9339 Air Content Method ASTM C-231-B Ticket Number: 705236 Slump: 5 in Concrete Temperature: 90° F Placement Location: Paving Sample Location: Time Batched: Air Content: Ambient Temperature: 73° F 8:12 Time Sampled: 8:50 4.5 % Unit Weight: n/a Yardage (c.y.): 490 20' N. & 10' E. From The N.W. Corner of Building H Age Max Load Area Strength Fracture Set # Cyl~der Test Date (days) (lbs. force) (sq.in.) (psi) Type 4 SLC08090413 08/16/2004 7 4 SLC08090414 08/23/2004 14 4 SLC08090415 09/06/2004 28 4 SLC08090416 09/06/2004 28 75365 28.27 2660 Normal cylinder size: 6" x 12" Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or.C1231. TERRA-MAR, INC. Construction Division Manager The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is strictly prohibited without the express written consent of TMI. Page 4 of 4