Loading...
St Andrews Est-LR040817ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 TESTED FOR: ST. ANDREWS LAND COMPANY CARROLLTON, TEXAS REPORT OF FIELD COMPACTION TESTS DATE: 08/17/04 PROJECT: ST. ANDREWS ESTATES COPPELL, TEXAS OUR REPORT NO.: 04219-17 TEST DATA: TEST ~ ELEV SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE~EPTH'~,,h NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY C¢ ~PACTION COMMENT* 71 08/17/04 FO-7.0 3 24.0 95.5 26.6 92 96 1-A 72 08/17/04 FO-6.5 3 24.0 95.5 25,6 92 97 1-A 73 08/17/04 FG~.0 3 24.0 95.5 25.4 92 97 1-A 74 08/17/04 FO-5.5 3 24.0 95.5 26.1 93 97 1-A 75 08/17/04 FG-5.0 3 24.0 95.5 24.5 94 98 1-A 76 08/17/04 FO-4.5 3 24.0 95.5 27.4 92 96 1-A 77 08/17/04 FO-4.0 3 24.0 95.5 24.5 93 98 I~A TE~;T LOCATION: UTI! ITIFR 71 SANITARY SEWER LINE A AT STATION 1+30 72 SANITARY SEWER LINE A AT STATION 1+30 73 SANITARY SEWER LINE A AT STATION 1+30 74 SANITARY SEWER LINE A AT STATION 1+30 75 SANITARY SEWER LINE A AT STATION 1+30 76 SANITARY SEWER LINE A AT STATION 1+30 77 SANITARY SEWER LINE A AT STATION 1+30 CC: HENNESSEY ENGINEERING; CITY OF COPPELL / // / / 1. FILL ' A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIO~IS / STURE DOES NOT COMPLY WITH SPECIFICATIONS 4 CEMENT TREATED D RETEST ~HAN k TESTING, INC. Geotechnical Engineering ~ Construction Materials Testing ~ Environmental Engineering /h Consulting ALPHA TESTINg, INC. 2209 Wisconsin St., Suite I00 DQIIOS, Texa~ 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 TESTED FOR: ST, ANDREWS LAND COMPANY CARROLLTON, TEXAS REPORT OF FIELD COMPACTION TESTS DATE: 08/17/04 PROJECT: ST. ANDREWS ESTATES COPPELL, TEXAS OUR REPORT NO.: 04219-17A TEST DATA: TEST ~ELEV SOIL ID OPTIMUM MAXIMUM LA~ IN PLACE IN PLACE PERCENT NO. DATEDEPTH~ NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT* % PCF % PCF 78 08/17/04 FG-3.5 3 24.0 95.5 26.0 92 ~96 1-A 79 08/17/04 FG-3.0 3 24.0 95.5 26.0 92I 9 6 1-A 80 08/17/04 FG-2.5 3 24.0 95.5 26.1 92 96 1-A 81 08/17/04 FG-2.0 3 24.0 95.5 26.3 92 96 I-A 82 08/17/04 FG-I.5 3 24.0 95.5 24.6 92 97 1-A 83 08/17/04 FG-I.0 3 24.0 95.5 25.9 92 97 1-A 84 08/17/04 FG-0.5 3 24.0 95.5 24.6 93 98 1-A TEST LOCATION: UTILITIES 78 SANITARY SEWER LINE A AT STATION 1+30 79 SANITARY SEWER LINE A AT STATION 1+30 80 SANITARY SEWER LINE A AT STATION 1+30 81 SANITARY SEWER LINE A AT STATION 1+30 82 SANITARY SEWER LINE A AT STATION 1+30 83 SANITARY SEWER LINE A AT STATION 1+30 84 SANITARY SEWER LINE A AT STATION 1+30 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS d 3. LIME STABILIZED 4 CEMENT TREATED C, PERCENT IN PLACE MOrSTURE DOES NOT COMPLY WITH SPECIFICATIONS D. RETEST h express approval of lot indicative of the qualities of Geotechnical Engineering /,~ Construction Materials Testing ~ Environmental Engineering /~ Consulting ALPHA TESTING, INC. 220~ Vlfl,~,onsln St., Suite 100 Do#os, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 TESTED FOR: ST. ANDREWS LAND COMPANY CARROLLTON, TEXAS REPORT OF FIELD COMPACTION TESTS DATE: 08/17/04 PROJECT: ST. ANDREWS ESTATES COPPELL, TEXAS OUR REPORT NO.: 04219-17B TEST DATA: TEST ~ ELEV. SOIL ID OPTII~'UM MAXIMUM LAB IN PLACE IN PLACE PERC~ENT NO. DATEDEPTH~,~ NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY~CTION COMMENT* % PCF % PCF 85 08/17/04 FG 3 24.0 95.5 26.8 91 96 ~ 1-A TESTLOCATION: UTILITIES 85 SANITARY SEWER LINE A AT STATION 1+30 CC: HENNESSEY ENGINEERING; CITY OF COPPELL / / ~ / / 1. FiLL * A, IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIOi~S ~ 2 NATURAL SUBGRADE S. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS ~Res~. ' ' 3 LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4. CEMENTTREATED D. RETEST Ou¢ test results and reports ere for the exdus, ...... , the Client ,and their designated recipients en file ,n our office, and shall not be reproduced and/or distdb~ _e~ ~w~;~' ,xpre;s approval Of ALPHA The use of o~r name ertl tes~ ~'esults must receive OUr w~itten approval Test results and repor[s apply only to Ihe samples tested and/or obse~ed, ar. 'e not indicalive of the qualities of apparently identical or similar specimens Geotechnical Engineering ~ Constroction Materials Testing ~h Environmental Engineering ~ Consulting