Loading...
PA9702-LR 990506 (3)IN-PLACE DENSITY STING 8901 Carpenter Frwy., Suite #10~ Dallas, Texas 75247 Date of Service: 04/28/1999 Report No.: 9911949 Report Date 05/06/1999 Client No.: COPPELL Project No.: 94991118 Client: City of Co pell Project: Coppell Aquatic/Recreation Ctr Attn: Bra~VReid 300 Block of Parkway Blvd 732 DeForest Coppell, Texas/Prj. #96051 Coppell TX 75019 Services: In-place density testing. PROJECT DATA CONTRACTOR: Hisaw & Assoc. Laboratory Test Method: ASTM D-698 Field Test Method: ASTM D-2922 ASTM D-3017 MOISTURE DENSITY RELATIONS: Maximun~ Projt~t Require~nents M/D No. Description Moisture % Density I~f Moisture Densay I Dk to med brown silty clay 17.5 101.5 +3% or above 92% FIELD DENSITY TESTS TEST MfD MOISTURE DRY DENSITY DENSITY NO TEST LOCATION No. (%) (pcf) (% max) Moisture Conditioned I Building Pad, Grid line H.5/13.5, 1st lift I 20.5 95.8 94 2 Building Pad, Grid line H.8/13, 2nd lift 1 21.0 96.7 95 3 Building Pad, Grid line H.5/13.8, 3rd lift I 20.8 97.8 96 4 Building Pad, Grid line H.5/9, 1st lift I 22.0 97.3 96 5 Building Pad, Grid line H.5/9.5, 2nd lift I 21.3 98.1 97 6 Building Pad, Grid line H.5/9.8, 3rd lift I 21.0 97.0 96 Test results on this report meet project specification. Technician: Roy Montgomery