St Andrews Est-LR040916ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(972) 620-8911
Concrete Compression Test
Report
Tested For: ST. ANDREWS LAND COMPANY
AFl'N: TERRY HOLMES
Fax Number: (972) 242-2931 ~.~,~,~-
Project Doac: ST. ANDRE~.F~:~A"~'~J
OFF DEFTEST RD J~ WEST OF STRATFORD LN
FIELD DA TA
Our Redort No.: 04219-15
Issue Date: 09116/2004
Placement Location: MANHOLE, LINE A ~ STATION 0+00
Date Placed: 08112/04
Time Placed: 1:40 PM
Slump (ASTM C-143): 2.75
Air Content: N/A
Air Temperature: 82
Speclman Temperature: 88
Date Received: 08/13/04
Delivery Method: PICKED UP BY ALPHA
Field Data Submitted By: TINOCO, ARTHURO
Mix Data Submitted By: REDI-MIX
Plant Number: 1-4200
Daliverj Ticket No.: 133482
Made By: ALPHA
Cured Specification: ASTM C-31
CYLINDER COMPRESSION TEST RESULTS
Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max
No.: Type: Spec: Tested: (Days): Len~lth Width Diameter Sq. In. Load: PSi:
1 LAB C-1231 08/19/04 7 12 N/A 6 28.27 135120 4780
2 LAB C-1231 09/09/04 28 12 NIA 6 28.27 174220 6160
3 LAB C-1231 09109/04 28 12 N/A 6 28.27 175000 6190
4 LAB HOLD HOLD 12 N/A 6 28.27 0
Specifications: 28 3000_
Results to Date: PASS
CC; ST. ANDREWS !.~ND COMPANY, HENNESSEY ENGINEERING, CITY OF COPPELL
Our test results and repo;ts are for the exclus~ u~ of the Cl,ent (and their designated mceplents on file in our office) and shall not be reproduced and o d
except with express approval of ALPHA The use of our name and test results must receive our written approval. Test results and repe~ts apply only to the samples
tested and/or obsen~ed, and are not indicative of the qualities of apparently identical or similar specimens
Geotechnloal Engineering * Construction Materials Testing ' Environmental Engineering * Consulting