Loading...
St Andrews Est-LR040916ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 Concrete Compression Test Report Tested For: ST. ANDREWS LAND COMPANY AFl'N: TERRY HOLMES Fax Number: (972) 242-2931 ~.~,~,~- Project Doac: ST. ANDRE~.F~:~A"~'~J OFF DEFTEST RD J~ WEST OF STRATFORD LN FIELD DA TA Our Redort No.: 04219-15 Issue Date: 09116/2004 Placement Location: MANHOLE, LINE A ~ STATION 0+00 Date Placed: 08112/04 Time Placed: 1:40 PM Slump (ASTM C-143): 2.75 Air Content: N/A Air Temperature: 82 Speclman Temperature: 88 Date Received: 08/13/04 Delivery Method: PICKED UP BY ALPHA Field Data Submitted By: TINOCO, ARTHURO Mix Data Submitted By: REDI-MIX Plant Number: 1-4200 Daliverj Ticket No.: 133482 Made By: ALPHA Cured Specification: ASTM C-31 CYLINDER COMPRESSION TEST RESULTS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Spec: Tested: (Days): Len~lth Width Diameter Sq. In. Load: PSi: 1 LAB C-1231 08/19/04 7 12 N/A 6 28.27 135120 4780 2 LAB C-1231 09/09/04 28 12 NIA 6 28.27 174220 6160 3 LAB C-1231 09109/04 28 12 N/A 6 28.27 175000 6190 4 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 3000_ Results to Date: PASS CC; ST. ANDREWS !.~ND COMPANY, HENNESSEY ENGINEERING, CITY OF COPPELL Our test results and repo;ts are for the exclus~ u~ of the Cl,ent (and their designated mceplents on file in our office) and shall not be reproduced and o d except with express approval of ALPHA The use of our name and test results must receive our written approval. Test results and repe~ts apply only to the samples tested and/or obsen~ed, and are not indicative of the qualities of apparently identical or similar specimens Geotechnloal Engineering * Construction Materials Testing ' Environmental Engineering * Consulting