Loading...
St Andrews Est-LR040915ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 TESTED FOR: ST. ANDREWS LAND COMPANY CARROLLTON, TEXAS REPORT OF FIELD COMPACTION TESTS DATE: 09115/04 PROJECT: ST. ANDREWS ESTATES COPPELL, TEXAS OUR REPORT NO.: 04219-32 TEST DATA: TEST ~ ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO, DATEDEPTH~ NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT* % PCF % PCF 512 09/15/04 FG-4.0 3 24.0 95.5 25.5 92 96 1-A 513 09/15/04 FG-3.5 3 24,0 95.5 25,4 92 96 1-A 514 09/15/04 FG-3.0 3 24.0 95.5 26.1 92 96 1-A 515 09/15/04 FG-2.5 3 24,0 95.5 25.3 93 97 1 -A 516 09/15/04 FG-2.0 3 24.0 95,5 26.4 92 96 1-A 517 09/15/04 FG-1.5 3 24.0 95.5 24.1 94 98 1-A 518 09/15/04 FG-1.0 3 24.0 95.5 24.7 93 98 1-A TEST LOCATION: UTILITIES 512 WATER LINE FOR ST. ANDREWS LANE AT STATION 9+00 513 WATER LINE FOR ST. ANDREWS LANE AT STATION 9+00 514 WATER LINE FOR ST. ANDREWS LANE AT STATION 9+00 515 WATER LINE FOR ST, ANDREWS LANE AT STATION 9+00 516 WATER LINE FOR ST. ANDREWS LANE AT STATION 9+00 517 WATER LINE FOR ST. ANDREWS LANE AT STATION 9+00 518 WATER LINE FOR ST. ANDREWS LANE AT STATION 9+00 CC: HENNESSEY ENGINEERING; CITY OF COPPELL 1 FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS ~--Respectful~y,--- ,,,___...Submitted 3 LIME STABILIZED C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS r~[ov---- -- V ~t,,4 ~ 4 CEMENTTREATED D RETEST ROY~VELEZTi~]ES I~, ALPHA T INC. Our test results and reports are for the exclusive use of the C~ier~t (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA TheuSeofournameandtestresu~tsmustreceiveourwrittenapproval Tes~resu~tsandrep~1sappIy~n~yt~thesamp~estestedand~r~bserved`andaren~indicatjve~f~hequ~ides~f apparently identical or similar specimens Geotechnical Engineering /. Construction Materials Testing /: Environmental Engineering f,' Consulting ALPHA TESTING, INC. 2209 Wisconsin St,, Suite 100 Do#os, Texos 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 TESTED FOR: ST. ANDREWS LAND COMPANY CARROLLTON, TEXAS REPORT OF FIELD COMPACTION TESTS DATE: 09/15/04 PROJECT: ST. ANDREWS ESTATES COPPELL, TEXAS OUR REPORT NO.: 04219-32A TEST DATA: TEST ~ ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATEDEPTH~ NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENS[i~ COMPACTION COMMENT* % PCF % PCF 519 09/15/04 FG-0.5 3 24.0 95.5 24.0 93 98 1-A 520 09/15/04 FG 3 24.0 95.5 25.4 93 97 1-A 521 09115/04 FG-4.0 3 24.0 95,5 25.4 92 97 1-A 522 09/15/04 FG-3.5 3 24.0 95.5 25.3 93 97 1-A 523 09/15/04 FG-3,0 3 24.0 95.5 25.8 93 97 1-A 524 09/15/04 FG-2.5 3 24.0 95.5 24.7 93 97 1-A 525 09/15/04 FG-2.0 3 24.0 95.5 26.2 92 97 1-A TEST LOCATION: UTILITIES 519 WATER LINE FOR ST. ANDREWS LANE AT STATION 9+00 520 WATER LINE FOR ST. ANDREWS LANE AT STATION 9+00 521 WATER LINE FOR ST. ANDREWS LANE AT STATION 11+10 522 WATER LINE FOR ST. ANDREWS LANE AT STATION 11+10 523 WATER LINE FOR ST. ANDREWS LANE AT STATION 11+10 524 WATER LINE FOR ST. ANDREWS LANE AT STATION 11+10 525 WATER LINE FOR ST, ANDREWS LANE AT STATION 11+10 CC: HENNESSEY ENGINEERING; CITY OF COPPELL 1 FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2 NATURAL SUBGRADE B PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS J~spectf~ly~;ub~itted 3 LIME STARILIZED C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS ~ 4. CEMENTTREATED D RETEST ROY~'ELEZ ~ ALPHA TESTIly, INC. Our test results end reports are fo~ the exclusive use of the Client (and theil designated recipients on file tn our office] and shall not be reproduced and/or distributed except with express approval of ALPHA The use of our name and test results must receive our written approval Test results and repo~ts apply only to the samples tested and/or observed, and are not indicative of the qualities of Geofechnical Enclineefinq / ConstRiction Materials Testina ~. Environmental Enclineenncl /~ Consultino ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dollas, Texas 75229 972/620-8911 - ~72/263.4937 (Metro) FAX: 972/406-8023 TESTED FOR: ST. ANDREWS LAND COMPANY CARROLLTON, TEXAS REPORT OF FIELD COMPACTION TESTS DATE: 09/15/04 PROJECT: ST. ANDREWS ESTATES COPPELL, TEXAS OUR REPORT NO.: 04219-32B TEST DATA: TEST ~ ELEV. SOIL ID OPTIMUM M~,XlMUM LAB IN PLACE IN PLACE PERCENT NO. DATEDEPTHS,,,,, NUMBER MOISTURE DRY DENSI3~ MOISTURE DRY DENSITY COMPACTION COMMENT* % PCF % PCF 526 09/15/04 FG-1,5 3 24.0 95.5 25.1 93 97 1-A 527 09/15/04 FG-I.0 3 24.0 95.5 25,2 93 97 1-A 528 09/15/04 FG-0.5 3 24.0 95.5 26.2 92 97 1-A 529 09/15/04 FG 3 24.0 95,5 25.6 92 96 1-A TEST LOCATION: UTILITIES 526 WATER LINE FOR ST. ANDREWS LANE AT STATION 11+10 527 WATER LINE FOR ST. ANDREWS LANE AT STATION 11+10 528 WATER LINE FOR ST. ANDREWS LANE AT STATION 11+10 529 WATER LINE FOR ST. ANDREWS LANE AT STATION 11+10 CC: HENNESSEY ENGINEERING; CITY OF COPPELL 1. FILL * A IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS ~spec~ffed 3 LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS V 4 CEMENTTREATED D. RETEST ROY~'ELEZ ~ ALPHA TESTII~NC. Our test results and reports are for [he exclusive use of the Criem (and their designated recipients on file in our office) and shall not be reproduCed and/or distributed except with express approval of ALPHA The use of out name and test results must receive our '.wltt e n approval Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens Geotechnical Engineering £ Construction Materials Testing /: Environmental Engineering P' Consulting