St Andrews Est-LR040909ALPHA TESTING, INC. 2209 Wisconsin ~t., Suite 100 Dallas, Texas 7522~ 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 TESTED FOR: PROJECT: ST. ANDREWS LAND COMPANY CARROLLTON, TEXAS ST. ANDREWS ESTATES COPPELL, TEXAS REPORT OF FIELD COMPACTION TESTS DATE: 09/09/04 OUR REPORT NO.: 04219-28 TEST DATA: SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE DATE NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY % PCF % PCF 09~09/04 FG-I.5 3 24.0 95.5 24.1 94 09/09/04 FG-1.0 3 24.0 95.5 24.6 93 09/09/04 FG-0.5 3 24.0 95.5 24.1 94 09/09/04 FG 3 24.0 95.5 24.3 93 09/09/04 FG-8.0 3 24.0 95.5 24.6 93 09/09/04 FG-7.5 3 24.0 95.5 24.4 93 FG-7.0 3 24.0 95.5 25.0 93 09/09/04 TEST LOCATION: UTILITIES COMMENT* 1-A 1-A 1-A 1-A 1-A 1-A 1-A 379 SANITARY SEWER SERVICE TO BLOCK A, PAD 16 380 SANITARY SEWER SERVICE TO BLOCK A, PAD 16 381 SANITARY SEWER SERVICE TO BLOCK A, PAD 16 382 SANITARY SEWER SERVICE TO BLOCK A, PAD 16 383 SANITARY SEWER SERVICE TO BLOCK A, PAD 17 384 SANITARY SEWER SERVICE TO BLOCK A, PAD 17 385 SANITARY SEWER SERVICE TO BLOCK A, PAD 17 CC: HENNESSEY ENGINEERING; CITY OF COPPELL 1 FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2, NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS ~,j~ pectful~u~S~s bmitted 3 LIME STABIL~ED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS ~OV ~ ROY V'ELEsZTiNG~iC 4 CEMENT TREATED D. RETEST ALPHATE Our test results a~d repotls are for the exclusive use of the Client (and tbe{r designated recipients on file ir) our office) and shall not be red~'oduced ar~or distributed excep~ with express approval of ALPHA The use ol our name and test results must receive our w~iUen approval Test resu([s and repons apply only to the samples tested and/or obse~ed, and are not indicative of the dualities of apparently identical or similar specimens Geotechnical Engineering #' Construction Materials Testing /7~ Environmental Engineerfng ~' Consulting ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Do#as, Texos 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 TESTED FOR: ST. ANDREWS LAND COMPANY CARROLLTON, TEXAS REPORT OF FIELD COMPACTION TESTS DATE: 09/09/04 PROJECT: ST. ANDREWS ESTATES COPPELL, TEXAS OUR REPORT NO.: 04219-28A TEST DATA: TEST ~ ELEV. SOIL ID OPTi~JM MAXJMUM LAB IN PLACE IN PLACE PERCENT NO. DATEDEPTHS,,,h NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY CO~PACTION COMMENT* % PCF % PCF 386 09/09/04 FG-6.5 3 24.0 95.5 26.6 91 95 1-A 387 09/09/04 FG-6.0 3 24.0 95.5 24.7 94 98 1-A 388 09/09/04 FG-5.5 3 24.0 95.5 25.2 93 97 1-A 389 09~09~04 FG-5.0 3 24.0 95.5 25.3 93 97 1-A 390 09/09/04 FG-4.5 3 24.0 95.5 25.9 93 97 1-A 391 09/09/04 FG-4.0 3 24.0 95.5 26.3 92 96 1-A 392 09/09/04 FG-3.5 3 24.0 95.5 25.7 93 98 1-A TESTLOCATION: UTILITIES 386 SANITARY SEWER SERVICE TO BLOCKA, PAD 17 387 SANITARY SEWER SERVICE TO BLOCKA, PAD 17 388 ;ANITARY SEWER SERVICE TO BLOCK A, PAD 17 389 ;ANITARY SEWER SERVICE TO BLOCK A, PAD 17 390 SANITARY SEWER SERVICE TO BLOCK A, PAD 17 391 SANITARY SEWER SERVICE TO BLOCK A, PAD 17 392 SANITARY SEWER SERVICE TO BLOCKA, PAD 17 CC: HENNESSEY ENGINEERING; CITY OF COPPELL 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGNADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS J~jspectfu~.u~S bmitt d 3~ LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS [~ 4 CEMENT TREATED D. RETEST ROY~ELE~ /~CSTIN ,~ ALPHA TE Our ~est resu~ls and reports ara for the exclusive use of the Client (and their designated re~pients on file in our office) and shaft not be repn3duced and/or distributed except with express approval of ALPHA The use of our name and test results must receive our wi-it ten approval Test results and reporls apply only to the samples lasted and/or observed, end are not indicative of the qualities of apparently identiCal o~* similar specimens Geotechnical Engineering ~ Construction Materials Testing ~ Environmental Engineering ~ Consulting ALPHA TESTING, INC. 2209 WisconSin St., Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX; 972/406-8023 TESTED FOR: ST. ANDREWS LAND COMPANY CARROLLTON, TEXAS REPORT OF FIELD COMPACTION TESTS DATE: 09/09/04 PROJECT: ST. ANDREWS ESTATES COPPELL, TEXAS OUR REPORT NO.: 04219-28B TEST DATA: TEST ~ ELEV. SOIL ID OPT~UM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATEDEPTH~ NUMSER MOISTURE DRY DEN$~ MOISTURE ORY DENSI"~f COMPACTION COMMENT* 393 09/09/04 FG-3.0 3 24.0 95.5 25.4 94 98 1-A 394 09/09/04 FG-2.5 3 24.0 95.5 26.5 91 96 1-A 395 09/09/04 FG-2.0 3 24.0 95.5 26.5 91 95 1-A 396 09~09/04 FG-I.5 3 24.0 95.5 25.5 92 97 1-A 397 09/09/04 FG-I.0 3 24.0 95.5 27.4 91 95 1-A 398 09/09/04 FG-0.5 3 24.0 95.5 24.2 94 98 1-A 399 09/09/04 FG 3 24.0 95.5 24.6 93 98 1-A TEST LOCATION: UTILITIES 393 SANITARY SEWER SERVICE TO BLOCKA, PAD 17 394 SANITARY SEWER SERVICE TO BLOCK A, PAD 17 395 SANITARY SEWER SERVICE TO BLOCK A, PAD 17 396 SANITARY SEWER SERVICE TO BLOCK A, PAD 17 397 SANITARY SEWER SERVICE TO BLOCK A, PAD 17 398 SANITARY SEWER SERVICE TO BLOCK A, PAD 17 399 ~ANITARY SEWER SERVICE TO BLOCK A, PAD 17 CC: HENNESSEY ENGINEERING; CITY OF COPPELL Our test m~lts ~d re~s ~ for the ~usive use ~ ~ Client (and their designat~ r~ipients on ~e ~n our ~) and shalr not be re~u~d an~ distributed ex.pt with e~ress approval Geotechnical Engineedng ~' Const~ction Matedals Testing ~ Environmental Engineedng ~ Consulting ALPHA TESTINg, INC. 2209 WIsconsln St., Sulte 100 Do#as, Texas 7,5229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 TESTED FOR: ST. ANDREWS LAND COMPANY CARROLLTON, TEXAS REPORT OF FIELD COMPACTION TESTS DATE: 09/09/04 PROJECT: ST. ANDREWS ESTATES COPPELL, TEXAS OUR REPORT NO.: 04219-28C TEST DATA: TEST ~ ELEV. SOIL ID O~T~U~ M/~XlMUM LAB IN P!.~E IN PIJ~CE PERCENT NO. DATEDEPTH'~ NUMBER MOISTUP~ DRY DENSITY MOISTURE DRY D~NSITY COMPACTION COMMENT' 400 09/09/00 FG-8.0 3 24.0 95.5 26.2 92 97 1-A 401 09/09/00 FG-7.5 3 24.0 95.5 24.4 93 98 1-A 402 09/09/00 FG-7.0 3 24.0 95.5 25.9 92 97 1-A 403 09/09/04 FG-6.5 3 24.0 95.5 24.8 93 97 1-A 404 09/09/04 FG~.0 3 24.0 95.5 25.4 92 97 1-A 405 09/09/04 FG-5.5 3 24.0 95.5 26.1 92 96 1-A 406 09/09/04 FG-5.0 3 24.0 95.5 25.2 93 97 1-A TEST LOCATION: UTILITIES 400 SANITARY SEWER SERVICE TO BLOCK A, PAD 18 401 SANITARY SEWER SERVICE TO BLOCK A, PAD 18 402 SANITARY SEWER SERVICE TO BLOCK A, PAD 18 403 SANITARY SEWER SERVICE TO BLOCKA, PAD 18 404 SANITARY SEWER SERVICE TO BLOCK A, PAD 18 405 SANITARY SEWER SERVICE TO BLOCKA, PAD 18 406 SANITARY SEWER SERVICE TO BLOCK A, PAD 18 CC: HENNESSEY ENGINEERING; CITY OF COPPELL 1. FILL 'A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURALSUBGRADE B PERCENT eOMPACTION DOES NOT COMPLY WITH SPECIFICATIONS ~spectflJ~¥ S~bmi~.d 3 LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS ¥ 4 CEMENT TREATED D. RETEST ROY ~ELEZ ALPHA TESTING~C. Geotechnical Engineering /~ Construction Materials Testing ~ Environmental Engineering ~ Consulting ALPHA TESTINg, INC. 2209 Wisconsin St., Suite 100 Do#os, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 TESTED FOR: ST. ANDREWS LAND COMPANY CARROLLTON, TEXAS REPORT OF FIELD COMPACTION TESTS DATE: 09~09~04 PROJECT: ET. ANDREWS ESTATES COPPELLTEXAS OUR REPORT NO.: 04219-28D TEST DATA: TEST ~ ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN pLACE PERCENT NO. DATEDEPTH"~ NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSrI'Y COMPACTION COMMENT* % PCF % PCF 407 09/09/04 FG-4.5 3 24.0 95.5 26.0 92 96 I~A 408 09/09/04 FG-4.0 3 24.0 95.5 27.2 91 95 1-A 409 09/09/04 FG-3.5 3 24.0 95.5 27.0 92 96 1-A 410 09/09/04 FG-3.0 3 24.0 95.5 24.4 94 98 1-A 411 09/09/04 FG-2.5 3 24.0 95.5 24.8 93 98 1-A 412 09/09/04 FG-2.0 3 24.0 95.5 25.4 92 96 1-A 413 09/09/04 FG-I.5 3 24.0 95.5 24.3 94 98 1-A TEST LOCATION: UTILITIES 407 SANITARY SEWER SERVICE TO BLOCKA, PAD 18 408 SANITARY SEWER SERVICE TO BLOCK A, PAD 18 409 SANITARY SEWER SERVICE TO BLOCK A, PAD 18 410 SANITARY SEWER SERVICE TO BLOCKA, PAD 18 411 ~ANITARY SEWER SERVICE TO BLOCK A, PAD '18 412 SANITARY SEWER SERVICE TO BLOCK A, PAD 18 413 SANITARY SEWER SERVICE TO BLOCK A, PAD 18 CC: HENNESSEY ENGINEERING; CITY OF COPPELL 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2 NATURALSUBORADE B. PE"CENTCOMPACTIONDOESNOTCOMPLYWlTHSPECIPICATIONS ~spe~fful~13~i~d 3. LIME STABILIZED C. PERCENT I" PLACE MOISTURE DOEB NOT COMPLY WITH SPECIFICATIONS V 4. CEMENTTREATED D. RETEST ROY~'ELEZ /) ALPHA TESTIN(~,,TINC Our test results and reports are fo~ the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or dist~butod except with express approval of ALPHA The use of our name am:l test resulls mus( receive cur wTitten approval Test resutts end reports apply only to the samples tested and/or observed, and are not indicative of the quaJities of apparently identical or similar specimens Geotechnical Engineering ~ Construction Materials Testing ~h Environmental Engineering /~ Consulting ALPHA TESTINg, INC. 2209 Wisconsin St., Suite 100 D~lla~ Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972~-t~23 TESTED FOR: ST. ANDREWS LAND COMPANY CARROLLTON, TEXAS REPORT OF FIELD COMPACTION TESTS DATE: 09/09/04 PROJECT: ST. ANDREWS ESTATES COPPELL, TEXAS OUR REPORT NO.: 04219-28E TEST DATA: TEST ~ ELEV. SOIL ID OPTkMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATEDEPTH'~ NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT* % PCF % PCF 414 09/09/04 FG-1.0 3 24.0 95.5 25.4 93 97 I-A 415 09/09/04 FO-0.5 3 24.0 95.5 24.8 93 98 1-A 416 09/09/04 FG 3 24.0 95.5 25.9 93 97 1-A 417 09/09/04 FG-8.0 3 24.0 95.5 27.4 91 95 1-A 418 09/09/04 FO-7.5 3 24.0 95.5 26.3 92 96 1-A 419 09109/04 FG-7.0 3 24.0 95.5 25.0 93 97 1-A 420 09/09/04 FG~.5 3 24.0 95.5 26.8 93 97 1-A TEST LOCATION: UTILITIES 414 SANITARY SEWER SERVICE TO BLOCK A, PAD 18 415 SANITARY SEWER SERVICE TO BLOCK A, PAD 18 416 'SANITARY SEWER SERVICE TO BLOCK A, PAD 18 417 SANITARY SEWER SERVICE TO BLOCKA, PAD 19 418 SANITARY SEWER SERVICE TO BLOCK A, PAD 19 419 SANITARY SEWER SERVICE TO BLOCKA, PAD 19 420 SANITARY SEWER SERVICE TO BLOCK A, PAD 19 CC: HENNESSEY ENGINEERING; CITY OF COPPELL I FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2 NATURAL SUBGRADE B, PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS ~sp~lfu. l~' S~bmitted~ 3 LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS ~,y ~ ~ ROY V~LE~TiN~C' 4. CEMENT TREATED D. RETEST ALPHATE Our test results and reports are for {he exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA The use of OUr name and test resulls must receive our w~itten approval Test results and reports apply only [o the samples tested and/or observed, and are not indicative of the qualities of apparentry identical or similar specimens Geotechnical Engineering [,~ Construction Materials Testing /~ Environmental Engineering /~ Consulting ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dollo~ Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: ~72/406-8023 TESTED FOR: ST. ANDREVVS LAND COMPANY CARROLLTON, TEXAS REPORT OF FIELD COMPACTION TESTS DATE: 09/09/04 PROJECT: ST. ANDREWS ESTATES COPPELL, TEXAS OUR REPORT NO.: 04219-28F TEST DATA: TEST ~ ELEV. SOIL ID OPTIMUM MAX~4UM LAB IN PLACE IN PLACE PERCENT NO. DATEDEP~'"~ NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT* % PCF % PCF 421 09/09/04 FG-6.0 3 24.0 95.5 26.6 92 97 1-A 422 09/09/04 FG-5.5 3 24.0 95.5 26.4 91 95 1-A 423 09/09~04 FG-5.0 3 24.0 95.5 24.2 94 98 1-A 424 09~09/04 FG-4.5 3 24.0 95.5 25.8 93 97 1-A 425 09/09/04 FG-4.0 3 24.0 95.5 25.8 92 96 1-A 426 09/09104 FG-3.5 3 24.0 95.5 24.4 92 97 1-A 427 09/09~04 FG-3.0 3 24.0 95.5 26.1 92 96 1-A TEST LOCATION: UTILITIES 421 SANITARY SEWER SERVICE TO BLOCK A, PAD 19 422 ~ANITARY SEWER SERVICE TO BLOCK A, PAD 19 423 SANITARY SEWER SERVICE TO BLOCKA, PAD 19 424 SANITARY SEWER SERVICE TO BLOCK A, PAD 19 425 ~ANITARY SEWER SERVICE TO BLOCKA, PAD 19 426 SANITARY SEWER SERVICE TO BLOCKA, PAD 19 427 SANITARY SEWER SERVICE TO BLOCKA, PAD 19 CC: HENNESSEY ENGINEERING; CITY OF COPPELL 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS p y bmi d 3. L,ME STAS'L'ZED C, PERCE"T'" PLACE MO'STURE DOES NOT CO..LY W'TH SPEO,F'CAT'ONS RO'EL%~iNc 4. CEMENTTREATED D. RETEST ALPHATE , Our tes~ results and rape[Is are for the excJusive use Of the Client (and their designated recipients On file ~n OUr Office) ar~l shell not be reproduced and/or distributed except vath express approval of ALPHA The use of our name and test resutts must receive our wTitten approval Test results end reports apply only to the samples tasted and/or observed, and are not indiCative of the qualities of Geotechnical Engineering /~ Construction Materials Testing ~ Environmental Engineedng /:g Consulting