Coppell Comm 1R3-LR040527GEOTECHNICALAND ~ J~J I"-1 I I F=a
ENVIRONHENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
Royal Park
Freeport Parkway and Burns Street
Coppell, Texas
REPORTED TO: Hay & Jones
c/o Pritchard Associates
2500 Routh Street
Dallas, Texas 75201
ATTN: Mr. Brett Ratliff
REPORT NO. 32
REG PROJECT NO. 11150
SAMPLE DATE: 05-27-04
TECHNICIAN: P. Becerra
CONTRACTOR: McFadden & Miller
Location of Sample
ISet Number I Location I Quantity Represented
1 Northwest corner of parking lot 30/300
Design Information
Source of Concrete I Mix Identification I Specified Strength p.s.I.
TXI 8205 3500
Test Results
Set Cylinder Age {~ Total Load Compressive Average
N1o. J D Date Tested Test lbs. Strength p.s.i. Strength p.s.i.
8755 06-03-04 7 73320 2590
8755 06-24-04 28 110840 3920
8755 06-24-04 28 102390 3620 3770
Cylinder Data
Set Cylinder Time of Concrete Air I Ticket
No. I ID Slump Sample AirTemp. Temp. EntrainmentJ Number
1 8755 5.5 7:30AM 50 56 3.1 3542373
Mail
Distribution: (1) Pritchard Associates/Mr. Brett Ratliff
(1) McFadden & Miller/Mr. Jon Jacobson
(1) Azimuth Architecture/Mr. John Taylor
Submitted by:
REED ENGINEERING GROUP, LTD.
Original Signed By
Keith Atkins
Manager, C.M.T.
KEA/je
2424STUTZ DR. · SUITE400 · DALLAS. TX75235 * 7EL [2141350 5600 * F^X [2141350 0019
GEOTI~CHNICAL AND
ENVIRONHENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
Royal Park
Freeport Parkway and Burns Street
Coppell, Texas
REPORTED TO: Hay & Jones
c/o Pritchard Associates
2500 Routh Street
Dallas, Texas 75201
ATTN: Mr. Brett Ratliff
REPORT NO. 31
REG PROJECT NO. 11150
SAMPLE DATE: 05-26-04
TECHNICIAN: P. Becerra
CONTRACTOR: McFadden & Miller
Location of Sample
Set Number I Location I Quantity Represented
I Piers: F-6, E-6, D-6, C-6 and B-6 10/10
Design Information
Source of Concrete I Mix Identification I Specified Strength p.s.i.
TXI 9506 3000
Test Results
Cylinder I Age @ Total Load Average
ID Date TestedI Test lbs. Strength p.s.i.
Set Compressive
N1. I Strength p.s.i.
8605 06-02-04 7 81420 2880
8605 06-23-04 28 123720 4380
8605 06-23-04 28 124600 4410 4400
,~¥1inder Data
Set Cylinder Time of Concrete Air Ticket
No. ID Slump Sample Air Temp. Temp. Entrainment Number
I 8605 5.50 10:00AM 59 64 N/A N/A
Mail
Distribution: (1) Pritchard Associates/Mr. Brett Ratliff
(1) McFadden & Miller/Mr. Jon Jacobson
(1) Azimuth Architecture/Mr. John Taylor
Submitted by:
REED ENGINEERING GROUP, LTD.
Original Signed By
Keith Atkins
Manager, C.M.T.
KEA/je
2424STUTZ DR. * SUITE400 * DALLAS, TX 75235 * TEL [2141350 5600 * F^X[214] 3500019