Freeport NIP(8.0)-LR041005RoneEr gineers
Client:
Duke Realty Services, LP
Mr. Brian Straley
5495 Belt Line Rd., Ste 360
Dallas TX 75254
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
Report No.: 219368
Project No.: 049245
Date of Service: 09/27/2004
Report Date: 10/05/2004
Project: Freeport XI & XII
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement IocaUons, perform reqmred field testing, cast compressive strength samples and br ng
samples back to the laboratory for curing and testing in accordance with applicable standards.
CONTRACTOR: Duke Construction
CONCRETE SUPPLIER: Southern Star
pLANT: 27
SPECIFICATION REQUIREMENTS
STRENGTm 3000 psi ~ 28 Days
SLUMP (in): 5" - 7"
AIR (%): NA
TEST METHOD: ASTM C- 172
ASTM C-31 =~po]2
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-1231
ASIM C-39
PROJECT DATA
MIX DESIGN I.D.: 9337
PLACEMEnt DATE: 09/27/2004
WEATHER CONDITIONS: C]otldy
TIME SAMPLED: lh30am BATCHTIME: 10:38am
TEMPERATURE (F) - AIR 78 F CONCRETE: 82 F
TRUCK NO: 1015 TICK~T NO: 362756
AIR CONTENT (%): NA UNIT WEIGHT (pcf): IxIA
OVERALL PLACEMENT LOCATION:
Piers: See report #219367
MEASURED
SLUMP
(inches)
5.0
SAMPLE LOCATION:
REPORT OF TESTS
· ' 12"
Concrete Compressive Cyl nder 6 x
E.3-15/D.5-15
CYLINDER
MARKED DATE AGE DIAMETER
SET NO. TESTED (days) (inches)
10/04/2004 7 6.00
10/25/2004 28 0.00
10/25/2004 28 0.00
MAXIMUM COMPRESSIVE
AREA LOAD STRENGTH
(sq.in.) (lbs. force) (psi)
28.26 105720 3740
0.00
0.00
FRACTURE
TYPE
Unbonded Cap
Unbonded Cap
Unbonded Cap
1 4 Hold
See report %219367 for technician time.
Technician: Rick Smith
Report Distribution:
(1) Duke Realty Services, LP
( l ) Extr~met
(1) City of Coppell
(1) City of Coppell
Started: Finished:
K~~cott Watson, AET
CMT Operations Manager
LIMITATIONS: Thc test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition. appearance, performance, etc.) or any other feature of similax subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
01HG Page 1 ofl
Technician: Rick Smith
Report Distribution:
(1) Duke Realty Services, LP
( 1 ) Extranet
(1) City of Copp¢ll
(1) City of Coppell
Started:
Finished:
CMT Operations Manager