Loading...
TC Bank-CS041011T H £ C I T Y 0 F COl'FELL October 11, 2004 John Blacker, P.E Kimley-Horn and Associates, Inc. 2301 Eagle Parkway, Suite 185 Fort Worth, TX 76177 RE: Natches Trace Addition, Lot 1 Block C (Town Center Bank) Construction Plan Review Comments Dear Mr. Blacker: The City of Coppell has reviewed the referenced plans and has the following comments to offer: Plat - I. Please provide a copy for the City's records of the mutual access easement to be dedicated by separate instrument. 2. Modify the drainage easement to cover only that portion of the public drainage system. The curb inlet to be constructed within the parking area will be privately o~vned and maintained. Sheet C~3 Dimension Control Plan - l. The sidewalk is shown to connect to the existing barrier-free ramp. The barrier-free ramps need to be in accordance with ADA minimum requirements. If they are not, they should be reconstructed to those standards. 2. The radius of the fire lane at the entrance to Denton Tap should be a minimum of 30' or some other arrangement must be made with the Fire Marshal to provide for additional width of that driveway. 3. The portion of pavement constructed on the adjacent lot that is not within the mutual access easement should be either eliminated or additional easement should be acquired to cover this construction. 4. The pavement section should be 6" paving over 6" lime-stabilized subgrade for the fire lane, and a minimum of 5" for the parking area. Sheet C-4 Utility Plan - l. Provide a detector check for both the irrigation and domestic meters. Provide an appropriate tap service rather than a tapping sleeve and valve. See the city's standard details for additional information. 2. Where the new fire hydrants arc cut into the existing waterline, use a tapping sleeve and valve rather than a tee. 3. Construct a manhole at the location where the 6" sanitary sewer ties into the 8" sewer main. 2 4. Show the location of the FDC, which should be within 50 £ect of a fire hydrant, and on the same side of the fire lane. 5. ]'he valve where you terminate your two waterlines should be back one full joint of pipe from the end ofthe fire line. Grading and Drainage Plan - 1. The proposed curb inlet to be constructed within your parking area will be a privately maintained storm sewer inlet. As such, it should not be located within the drainage easement, Sheet C-8 Construction Details - 1. Again, the pavement section is 6" with a 6" lime-stabilized subgrade unless a written variance request is submitted and approved. Please make the necessary changes and submit these marked-up plans and two sets of revised plans to the City for revicw. If you have any questions, please contact this office at your convenience. Sincerely, Keith R. Marvin, P.E. Civil Engineer Office Phone: (972) 304-7044 Fax: (972) 304-3570