W Sandy Lk Addn-CS041027T H E C I T Y O F October 27, 2004 B. David Littleton, P.E. Halff Associates 8616 Northwest Plaza Drive Dallas TX 75225 West Sandy Lake Road Addition, Lot 1 Block 1 Third Submittal Construction Plan Review Comments Dear Mr. Littleton: The City of Coppell has reviewed the referenced plans and has the following comments to offer: 1. On the private waterline on the east side of the properly, relocate the valve fi-om the private side to the public side of the vault. 2. A clean-out or manhole is needed on the sanitary sewer line where thc two bends are located. 3. The FDC and fire lines going into the building are shown as 8" - coordinate with the Fire Marshal on size and capacity needed for sprinkler design. The Fire Marshal for the City of Coppell is Tim Oates, and he can be reached at (972) 304-7055. 4. TxDOT needs to approve the detail of the driveway connecting to SH 121 before any work commences on that drive. 5. Clarify the 5' x 2' box culvert under the drive (pre-cast or cast-in-place), how will it be installed'? Once these minor comments are addressed you will be ready for a permit to begin work on the utilities, drainage and paving onsite. Prior to commencing any work in TxDOT right-of-way, we will need a copy of the driveway permit. TxDOT will probably rcquire a traffic control plan and we will want to review that as well. Please provide our office with three sets of final plans, provide two half-sized sets for TxDOT, and the number of sets you need stamped for your contractors onsite. A Construction Development Permit application (attached) must be filled out and submitted with a check for Construction Inspection fees. A spreadsheet is provided for your convenience in calculating the fees, and copies of the contracts should be provided for verification of the amount. A pre-construction conference will be scheduled with the assigned inspector when the permit and inspection fees are submitted. Also, ensure that we have all other required documentation including a copy of the executed NO1, and any other pertinent documentation. If you have any queslions or need any further information, please contact me at the number below. Sincerely, - Keith R. Marvin, P.E. Civil Engineer Office Phone: (972) 304-7044 Fax: (972) 304-3570