Loading...
SS9901-LR041005Construction Materials Testing and Environmental Consulting Tex s CMT, Inc. 10044 Monroe Drive Dallas, Texas 75229 (214) 352-6957 Fax (214) 352-6972 www .texascmt.com REPORT OF CONCRETE MIX OBSERVATION Report Date: October 5, 2004 Date Concrete Placed: September 7, 2004 Client: City of Coppell Prqiect: DeForest Lift Station, Coppell Contractor: S.J. Louis Construction Concrete Supplier and Plant: LMC # 11 Location of Placement: Manhole Standard 6"x12" Area 28.27 Square Inches Concrete Report No.: 11 Project No.: 204-0125 MATERIALS Source~ SSD Batch Wt$ OBSERVATION DATA Descdptlon (Lb~CuYd) Mix Number: 1701 Time Sample Batched: 09:42 am Cement: Time Sampled: 10:40 am Fly Ash: Sample Location: Station 19+07, MacArthur Rd. median island - manhole release Coarse Aggregate: Truck/Ticket No: I I 18/6232775 Intermediate Aggregate: Temperature: Fine Aggregate: ganbient Range: 80°F Admixtures: Concrete Range: 82°F Slmnp Range (inches): 3½" I Weather Conditions: Clear 2 Time Started: 09:30 am Added Water: 0 gallons Time Completed: 11:30 am Sample Air Content (%): N/A Total Cubic Yards Placed: 10 Requi~ J Strength (Lbs./sq.in. 4,000 Number Slump (in ~ (DaysI Tested (LBs ) (Lbs/Sq In ) Remarks DLS 41 7 09/14/04 104,020 3,680 DLS 42 28 10/05/04 122,540 4,330 DLS 43 3 v," 28 10/05/04 123,900 4,380 DLS 44 H HOLD ASTM C-31,C-39,C-143 (Unless Noted Otherwise) Cylinders Made By: AB Remarks and/or Distribution: cc: Mr. Rick O'Dell - City of Coppell \~ Mr. Ted B, Sugg - Turner Collie & Braden, Inc. t~ / /~x, Mr Sam Montoya- S.J. Louis Construction of Texas LTD. (Retests-densities) ~ ~- Texas CMT, Inc. Reviewed by: