SS9901-LR040909Construction Materials Testing and Environmental Consulting Texas CMT, Inc. 10044 Monroe Drive Dallas, Texas 75229 (214) 352-6957 Fax (214) 352-6972 ww~v .texascmt.com REPORT OF CONCRETE MIX OBSERVATION Report Date: September 9, 2004 Date Concrete Placed: September 3, 2004 Client: City of Coppell Px~lect: DeForest Lift Station, Coppell Can:ratter: S.J. Louis Construction Concrete Supplier and Plant: LMC #6 Location of Placement: Manhole Base Standard 6'x12' Area 28.27 Square Inches Concrete Report No.: 9 Project No.: 204-01 2 5 MATERIALS Sour~S SSD Batch Wts OBSERVATION DATA De~¢ripIlon (Lbs/CuYd) Mix Nmnber: 1701 Time Sample Batched: 02:15 pm Cement: Time Sampled: 03:35 pm Fly Ash: Sample Location: Station 26+40 Track/Ticket No: 821/6232615 Coarse Aggregate; Temperature: Intermediate Aggregate: Ambient Range: 93°P Fine Aggregate: Concrete Range: 94°F Admixtures: Slump Range (inches): 1 Weather Conditions: Clear I Time Started: 02:00 pm 2 Time Completed: 05:00 pm Added Water: 0 gallons Sample Air Content (%): 3% Total Cubic Yards Placed: 10 Required Strength (Lbs/sq in 4,000 Specmlen Measured Age Date Total Load Compressive Strength Remarks Number Slump (in) (Da~$) Tested (Lbs ) (Lbs/Sq In } DLS 34 7 09/09/04 122,520 4,330 DLS 33 28 09/30/04 DLS 35 28 09/30/04 DLS 36 H ] HOLD [ ASTMC-31,C-39,C-143 (Unless N0tedOthelwise) Cylinders Made By: EA Remarks and/or Distribution: cc: Mr Rick O'Dell - City of Coppell Mr Ted B Sugg - Turner Collie & Braden, Inc. Mr Sam Montoya - SJ Louis Construct/on of Texas LTD. (Retests-densities) Texas CMT, Inc. Reviewed by: