SS9901-LR040707Construction Materials Testing and Environmental Consulting Texas CM% Inc.. 10044 Monroe Drive Dallas, Texas 75229 (214) 352-6957 Fax (214) 352-6972 www .texascmt.com MOISTURE DENSITY RELATIONSHIP REPORT Test Report Date: Client: Sample Date: Project: Identification: Test Procedure: July 7, 2004 City of Coppell July 2, 2004 DeForest Lift Station, Coppell Moisture Density Relationship ASTM D698 Project No: 204-0125 Moisture Report No. 1 Test Results: Method .................................................. A Optimum Moisture Content .................................. 20.4 percent Maximum Density ......................................... 102.4 pounds per cubic foot Rammer Type ............................................. Automatic Material Description ....................................... Light Gray Clay w/occasional ......................................................... calcareous nodules Material Origin ........................................... 60 yards north of Belt Line Moisture Preparation Procedure .............................. Air Dry Liquid Limit ............................................. 44 Plastic Limit ............................................. 18 Plasticity. Index ........................................... 26 Percent Passing No. 200 U.S. Sieve ........................... 66 Technician:AT Mr. Rick O'Dell - City of Coppell Mr. Ted B. Sugg - Turner Collie & Braden, lnc Mr. Sam Montoya - S.J. Louis Construction of Texas LTD. (Relests-densities) Our letters and reports are t~r the exclusive use of the client to whom they are addressed The use of our name must receive our prior written approval Our letters and reports apply only to the sample tested and/or observed, and are not necessarily indicative of the quantities of apparently identical or similar products