MOISTURE DENSITY RELATIONSHIP REPORT
Test Report Date:
Client:
Sample Date:
Project:
Identification:
Test Procedure:
July 7, 2004
City of Coppell
July 2, 2004
DeForest Lift Station, Coppell
Moisture Density Relationship
ASTM D698
Project No: 204-0125
Moisture Report No. 1
Test Results:
Method .................................................. A
Optimum Moisture Content .................................. 20.4 percent
Maximum Density ......................................... 102.4 pounds per cubic foot
Rammer Type ............................................. Automatic
Material Description ....................................... Light Gray Clay w/occasional
......................................................... calcareous nodules
Material Origin ........................................... 60 yards north of Belt Line
Moisture Preparation Procedure .............................. Air Dry
Liquid Limit ............................................. 44
Plastic Limit ............................................. 18
Plasticity. Index ........................................... 26
Percent Passing No. 200 U.S. Sieve ........................... 66
Technician:AT
Mr. Rick O'Dell - City of Coppell
Mr. Ted B. Sugg - Turner Collie & Braden, lnc
Mr. Sam Montoya - S.J. Louis Construction of Texas LTD. (Relests-densities)