ST9302-CN0009074019BobbinLane Addison, Texas75001 City of Coppell Att: Ken Griffin 255 Parkway Blvd. Coppell, Texas 75019 JOB: Irrigation, Inc. Design · Installation · Service Residential & Commercial Date 9-7-2000 Entrance and Frontage Irrigation System / Pecan Ridge Homeowners Association North side of Sandy Lake Road at Pecan Ridge. (972) 243-3989 (817) 284-6400 RE: Irrigation System Dear Mr. Griffin, We are pleased to submit the following proposal for your consideration. Norway will install a~lawn irrigation system in accordance with a sprinkler plan designed expressly for above and by the following specification: 1) Controller to be LMC-19 , W/ Rain/Freeze Sensors. 2) Approximately 113 lawn heads, Weathermatic #LX4 pop-up action, with MPR nozzles. 3) Approximately 8 sprinkler heads in shrub areas to be mounted on copper risers, brass nozzles and adapters. 4) ONE INCH Double Check assembly to be enclosed in box and shall conform to city specifications. 5) Approximately 14 Weathermatic #11024-10 FCR series electric valves shall be installed in 6" valve boxes. 6) Piping shall be Class 200, PVC, with Sch. 40 fittings. A flexible nipple shall be used between heads and pipe. 7) Direct burial wiring shall be #14 ga. UF coated copper. SPECIAL PROVISIONS: The plan shall be designed prior to installation and shall constitute a part hereof. Actual field conditions may indicate the advisability of adding additional equipment to insure uniform distribution and even coverage of moisture. Norway shall assume all cost incident to said installation of additional equipment. Post-it* Fax Note 7671 Date Oj-~'-O~I pagesl # of -· ~ i =o. ver) 4019BobbinLane Addison, Texas75001 City of Coppell Att: Ken Griffin 255 Parkway Blvd. Coppell, Texas 75019 JOB: Irrigation, Inc. Design · Installation · Service Residential & Commercial Date 9-7-2000 Entrance and Frontage Irrigation System / Pecan Ridge Homeowners Association North side of Sandy Lake Road at Pecan Ridge. (972) 243-3989 (817) 284-6400 RE: Irrigation System Dear Mr. Griffin, We are pleased to submit the following proposal for your consideration. Norway will install a~lawn irrigation system in accordance with a sprinkler plan designed expressly for above and by the following specification: 1) Controller to be LMC-19 , W/ Rain/Freeze Sensors. 2) Approximately 113 lawn heads, Weathermatic #LX4 pop-up action, with MPR nozzles. 3) Approximately 8 sprinkler heads in shrub areas to be mounted on copper risers, brass nozzles and adapters. 4) ONE INCH Double Check assembly to be enclosed in box and shall conform to city specifications. 5) Approximately 14 Weathermatic #11024-10 FCR series electric valves shall be installed in 6" valve boxes. 6) Piping shall be Class 200, PVC, with Sch. 40 fittings. A flexible nipple shall be used between heads and pipe. 7) Direct burial wiring shall be #14 ga. UF coated copper. SPECIAL PROVISIONS: The plan shall be designed prior to installation and shall constitute a part hereof. Actual field conditions may indicate the advisability of adding additional equipment to insure uniform distribution and even coverage of moisture. Norway shall assume all cost incident to said installation of additional equipment. (over) INSTALLATION shall be done in a professional and workmanlike manner. All trenches back-filled and shall be flooded in to prevent aftersettling, walks shall be clean and refuse removed. This contract is subject to acceptance within 30 days from the date hereof. Terms shall be Balance due upon completion of installation and performance of system. Total cost of this contract $10,400.00 ACCEPTED: y/.___~ Purchaser --.~/" ~.~--,e . _ (NO~y Ir ir gation) All materials are fully guaranteed for ONE year to be without defect, of standard quality or better, and the installed system is guaranteed for ONE year from date of completion to give uniform distribution and even coverage of moisture. Parts and Labor are included. Maintenance of the system, i.e., raising and lowering of heads to compensate for lawn growth, cleaning and adjustments of heads, raising and lowering of shrub heads to compensate for shrub growth, shall be given the purchaser of this system at no charge for one year from the completion of the installation as a part of this contract. Maintenance and guarantee as stated above does not include alterations due to relandscaping, accidents, vandalism or violent acts of nature. ~8/31/280~ 08:51 4019 Bobbin Lm~e Addison, Texas 75001 9722<$31823 ~w~Y IRRIr~TI~ Jerry Jones ~ary Kay A~h T. Boone Picken$ All Gainto ~tholic Reeidence Residence Residence Residence Chapel Commerical Couuercial Cities o~ Dallas, Carrollton, Farmers Breach, Rowlet~ ~lon Per~ ~aca~ ~chitect ~~r ~ ~m~ia~es ~rrige~ion Co~la=~ ~urice F~r ~sc~ I~i~a~ion Desirer S~eve M~ller ~8ca~ ArChi~ec~ Naud ~eu~ ~ Partners ~sca~ Architecture P/~,GE 03 Plant Care Xnc. North Dallas ~=den Center T~e coudrey coupany 1H