Freeport NIP(8.0)-LR041110lineers
8908 Ambassador Row', Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6500 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214} 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
Client:
Duke Realty Services, LP
Mr. Brian Straley
5495 Belt Line Rd., Ste 360
Dallas TX 75254
Project: Freeport XI & XII
Coppell, Texas
Report No.: 222024
Project No.: 049245
Date of Service: 11/02/2004
Report Date: 11/10/2004
Obtain samples of fi-esh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECTDATA
MEASURED
STRENGTH:
SLUMP (in):
AIR (%):
TEST METHOD:
co~,rRAcrOR: Duke Construction
CONCRETE SUPPLIER: Southerll Star
PLANT: 27
SPECIFICATION REQUIREMENTS
5000 psi @ 28 Days
4" - 6"
NA
ASTM C- 172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-1231
ASTM C-39
excopt 9 I 2
mx DESIGN I.D.: 9385
PLACEMENT DATE: 11/02/2004
WEATHER CONDITIONS: Cloudy
TIME SAMPLED: 10:55am BATCHTIME: NA
TEMPERATURE {F) - AIR 60 F CONCRETE: 74 V
TRUCK NO: 923 TlC~T NO: 756308
AIR CONTENT (%): NA UNIT WEIGHT (pcD: NA
OVERALL PLACEMENT LOCATION:
Piers, see Report #222023
SAMPLE LOCATION: Same as above
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
SLUMP
(inches)
4.75
CYLENDER MAXIMUM COMPRESSIVE
MARKED DATE AGE DIAMETER AREA LOAD STRENGTH FRACTURE
SET NO. TESTED (days) (inches) (sq.in.) (lbs. force) ?si) TYPE
1 1 11/09/2004 7 6.00 28.26 177400 ~..6270 Unbonded Cap
1 2 11/30/2004 28 0.00 0.00 Unbonded Cap
1 3 11/30/2004 28 0.00 0.00 Unbonded Cap
1 4 Hold
Water added at site: 5 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc) or any other feature of similar subject matter provided by persons or conditions over which we have no control Our leRers and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the wfiRen approval of Rone Engineers, Ltd.
01SS Page 1 of 2
Report No.: 222024
Project No.: 049245 Client: Duke Realty Services, LP
See Report %222023 for technician time.
Technician: Rick Smith
Report Distribution:
(1) Duke Realty Services, LP
( 1 ) Extra. net
(1) City of Coppell
(1) City of Coppell
Started: Finished:
K. Scott Watson, AET
CMT Operations Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing We assume no responsibility for variation in quality
(composition, appearance, performance, etc ) or any other feature of similar subject matter provided by persons or conditions over which we have no control Our lel~ers and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in fifll without the written approval of Rone Engineers, Ltd
01SS Page 2 of 2