Four Seasons 2R-LR041108FIELD DENSITY TESTING
Report Number: 94041388.0006
Service Date: October 27, 2004
'll'erracan
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
Client: Hill & Wilkinson LTD --,
Attn: Charles Hoagland
800 Klein Rd Ste 100
Piano TX 75074
Report Date~er 08, 2004
Projec~ Specialtie~'~"'"~ ,
100 Royal Lane
Coppell, TX
Project Number: 94041388
Material Information
Material Laboratory
No. Test Method
Description and Classification
Lab Test Data Proiect Requirements
Optimum Max. Lab Water
Water Dry Unit Content Minimum Dry
Content Weight Range Unit Weight
(%) (pct~ (%) (% compaction)
1.413880003 ASTM D 698
2.413880001 ASTM D 698
Field TestData
Test
No.
Test Location
Dark gray & brown clay w/sand
Brown silty clay w/gravel
Probe
Lift/ Mat. Depth
Elevation No. (inches)
Moisture Conditioned Bldg. Pad
1 Grid Line A-E/l-4
2 Grid Line A-E/l-4
3 Grid Line A-E/l-4
4 Grid Line A-E/l-4
5 Grid Line A-E/l-4
6 Grid Line A-E/l-4
7 Grid Line A-E/l-4
8 Grid Line A-E/4-5
9 Grid Line A-E/4-5
Datum: BEG = Below existing grade
7' BEG 1 6
6' BEG 1 6
5' BEG 1 6
4' BEG 1 6
3' BEG 1 6
2' BEG 1 6
1' BEG 1 6
7' BEG 2 6
6' BEG 2 6
19.7 101.1 +1/+5 92 - 98
17.2 105.7 +1/+5 92 - 98
Water Dry Unit Dry Unit
Content Weight Weight
(%) (pc0 (% compaction)
20.8 98.6
20.9 98.2 97
20.7 98.5 97
20.9 98.7 98
23.8 96.4 95
22.1 98.0 97
24.7 95.2 94
19.1 99.5 ~,94
18.8 100.3 \,~.
Comments:
Test results on this report meet project specifical
Services - Perform in-place density and moisture~
condition.
Field Test Method&STM D2922, ASTM D3017
Field Results Reported To: Superintendent
Technician: Armando Rendon
Report Distribution:
(1) Hill & Wilkinson LTD (1) BCE Specialties
(1) City of Coppel[ TX
(1) City of Coppelt TX
(1) Hardy McCulIah/MLM Architects Inc
~sts to determine degree of compaction and material moisture
Sn'oP j g
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of HBC/Terracon, Test results transmitted herein are only
applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or
identical materials,
Page I of 1