Loading...
Four Seasons 2R-LR041109FIELD DENSITY TESTING Report Number: 94041388.0008 Service Date: October 28, 2004 Client: Hill & Wilkinson LTD Attn: Charles Hoagland 800 Klein Rd Ste 100 Piano TX 75074 Report Date: Project: BCE Specialties 100 Royal Lane Coppell, TX Project Number: 94041388 lr'erracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 November 09, 2004 Material Information Material Laboratory No. Test Method Description and Classification Lab Test Data Project Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Content Weight Range Unit Weight (%) (pcf) (%) (% compaction) 1. 413880003 ASTM D 698 Dark gray & brown clay w/sand Field Test Data Probe Test Lift/ Mat. Depth No. Test Location Elevation No. (inches) 14 15 16 17 18 Datum: Building Pad, Moisture Conditioned Grid Line A-E/4-5 5' BEG 1 6 Grid Line A-E/4-5 4' BEG 1 6 Grid Line A-E/4-5 3' BEG 1 6 Grid Line A-E/4-5 2' BEG 1 6 Grid Line A-E/4-5 1' BEG 1 6 BEG = Below existing grade 19.7 101.1 +1/+5 92 - 98 Water Dry Unit Dry Unit Content Weight Weight (%) (pcf) (% compaction) 23.9 94.5 ~93 23.7 94.7 94 24.9 * 94.0 93 23.4 94.3 93 23.7 95.1 ,~9,4 Comments: An asterisk (*) appears next to test results which do NOT meet the project specifications. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method:ASTM D2922, ASTM D3017 Technician: Armando Rendon ,,,.¢ / // Report Distribution: // /f ~ (1) Hill & Wilkinson LTD (1) 8C5 Specialties , ///J/~ } / (1) CityofCoppellTX Rewewed by: ~ ~ - ' ~ ~ (1) City of Coppell TX Robe~ D. Ray, S~. ete s were performed in general accordance w~th apphcable ASTM, AASHTO, or DOT test methods. Th~s repo~ ~s exclu hent indicated above and shall not be reproduced except in full without the wri~en approval of HBC/Terracon. Test results transmi~ed herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the propeKies of other apparently similar or identical materials. FIELD DENSITY TESTING Report Number: 94041388.0007 Service Date: October 28, 2004 Client: Hill & Wilkinson LTD Attn: Charles Hoagland 800 Klein Rd Ste 100 Piano TX 75074 Report Date: Project: BCE Specialties 100 Royal Lane Coppell, TX Project Number: 94041388 'lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 November 09, 2004 Material Information Material Laboratory No. Test Method Description and Classification Lab Test Data Project Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Content Weight Range Unit Weight (%) (pc0 (%) (% compaction) 1. 413880003 ASTM D 698 Dark gray & brown clay w/sand 19.7 101.1 >/= Opt. 95 Field Test Data Probe Water Dry Unit Dry Unit Test Lift/ Mat. Depth Content Weight Weight No. Test Location Elevation No. (inches) (%) (pcf) (% compaction) Paving/Fire Lane __ 1~080 10 20' N & 20' W of NE corner of bldg. Subgrade I 6 19.9 98.9 98 11 20' N & 100' W of NE corner of bldg. Subgrade 1 6 19.9 100.9 12 20' N & 160' W of NE comer of bldg. Subgrade 1 6 20.3 100.6 __{100 13 20' N & 200' W of NE corner of bldg. Subgrade 1 6 19.7 99.9 ~ Comments: Test results on this report meet project specification, Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method:ASTM D2922, ASTM D3017 Technician: Armando Rendon (1) Hill & Wilkinson LTD (1) BCE Specialties (1) City of Coppell TX Reviewed by: _ (1) cry of Coppel[ TX Robert D. Ray,~'l'~ (1) Hardy McCullah/MLM Architects In¢ Senior Project, tanager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the'use of the client indicated above and shall not be reproduced except in full without the written approval of HBC/Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1