Loading...
St Andrews Est-LR041116ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 Concrete Compression Test Report Teated Fro': ST, ANDREWS LAND COMPANY A'I-rN: TERRY HOLMES 2629 DICKERSON PKVVY, STE 110 CARROLLTON, TX 75007 Fax Number: (972) 242-2931 Our R®port No.: 04219-40 Date: 11/16/2004 Project Desc: ST. ANDREWS ESTATES OFF DEFOREST RD JUST WEST OF STRATFORD LN FIELD DATA Placement Location: INLET WALLS, STONE WALK LN {~ STATION 3+50 Date Placed: 10/12/04 Time Pla~ed: 2:30 PM Slump (AST~ C-t43): 4.5 Air Content: 4.9 (ASTM C-173) Air Temperature: 68 Specimen Temperature: 79 Date Received: 10/13/04 Delivery I~xl: PICKED UP BY ALPHA Field Data Submitted By: WALTON, L Mix Data Submitted By: N/A Plant Number: N/A Delivery Ticket No.: NIA Made By: ALPHA Cured Specification: ASTM C-31 CYLINDER COMPRESSION TEST RESULTS Lab Cum Cap Date' Age Avg. Avg. Avg Depth/ Area: Max NO.: Spec: Tested: Width Diameter Sq. In. Load: PSI: 9 LAB C-1231 10/16/04 7 12 N/A 6 28.27 88170 10 LAB C-1231 11/09/04 28 12 N/A 6 28.27 126930 11 LAB C-1231 11/09/04 28 12 N/A 6 28.27 12 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 3000 I~eeUlte to Date: PAsS CC: S~ Respectfully Submitted By: of Alpha Testing, Inc. Our test resuEs and reports are for the exc~ the Client (and their designated recepients on file in our office} and shall not be reproduced and/or distributed except with express approval of ALPH.~3e u~e~f our name and test results must receive our written approval Test results and reports apply only to the samples tested and/or observed, and are not Indicative of the qualities of apparently identical or similar specimens. Gentechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 39215