Loading...
ST9902-CS041208 T H £ ' C: I T Y ' 0 F COPPE-IJL December 8, 2004 Phillip W. Porter SWP Consukants, Inc. 5443 S 99t~ East Ave Tulsa OK 74146 RE: Utility Relocation Submittal Dear Mr. Porter: The City of Coppell has received and reviewed the plans submitted for the Bethel Road relocation of 360Networks ;md Quest Communications facilities, and we have the following comments to offer: 1. Your installation is approximately 1.5' behind the proposed future curb inlets. I suggest you lower your installation adjacent to the proposed inlets so that you are a minimum 2' below the bottom of the proposed inlets as well. This would minimize the chance of the fiber being cut during excavation for the construction of the inlets. 2. It appears that you do not have the most recent set of plans for the end of your relocation at Freeport Parkway. That intersection will be widened south of Bethel Road on Freeport. I have attached the latest plan for your review. We have acquired the last portion of right-of-way so that is no longer a consideration for your construction schedule. Once you have reviewed the above comments and determined the best course of action, please submit any revised plans with the permit application for the Bethel Road relocation so that work can begin. A permit form is included with this letter. We have also reviewed the Sandy Lake Road reconstruction plans you submitted and have the following comments on those plans: 1. A portion of the work you are proposing is located within the City of Grapevine anct will need to be coordinated with them. 2. Your crossing of SH 121 will require a permit and coordination with TxDOT for that work. 3. We do not yet have right-of-way for the portion on the south side of Sandy Lake Rd. between SIt 121 and Royal Lane within the City of Coppell, so that work cannot take place until the ROW is acquired. 4. In addition, where you propose to emss Royal Lane, it appears that you are showing incorrect elevations of the box culverts under Royal. Please check those, I show an elevation of 514. Make sure you will be a minimum of 2' below that. 5. Verify the locations of the water and sewer lines that you propose to go between. You may have to go underneath both if the locations are different than shown. After you have reviewed the above comments, please provide us with updated plans. We will need verification from City of Grapevine that your proposed work in their limits is permitted, and a copy of the permit from TxDOT for the crossing of SH121. Feel free to call if you have any questions or comments. Sincerely, Keith R. Marvin, P.E. Civil Engineer Office: 972-304-7044 Fax: 972-304-3570 kmarvin~ci,co~oell.tx-us Attachments- plans, permit form