Loading...
St Andrews Est-LR041201ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 Concrete Compression Test Report Tested For: ST. ANDREWS LAND COMPANY ATI'N: TERRY HOLMES 2629 DICKERSON PKWY, STE 110 CARROLLTON, TX 75007 Fax Number: (972) 242-2931 project De.c: ST, ANDREWS ESTATES OFF DEFOREST RD JUST WEST OF STRATFORD LN Our Report NO.: 04219-52 Issue Date: 12101/2004 FIELD DA TA Placement Location: Date Placed: Time Placed: Slump (ASTM C-143): Air Content: Air Temperature: PAVING, ST. ANDREWS LN. ~ STATION 11+50 11/16/04 8:10AM 5.0 5.0 (ASTM C-173) 65 Specimen Temperature: 84 Date Received: 11117/04 Delivery Method: PICKED UP BY ALPHA Field Date Submitted By: ALEGRIA, ROBERT Mix Data Submitted By: LMC Plant Number: 3-3600 Delivery Ticket No.: 3186438 Made By: ALPHA Cured Specification: ASTM C-31 CYLINDER COMPRESSION TEST RESUL TS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max NO.: T~/pe: Spec: Teated: (Dal/a): Length Width Diameter Sq. In. Load: PSI: 13 LAB C-1231 11/23/04 7 12 NIA 6 28.27 107560 3800 14 LAB 12/14/04 28 12 N/A 6 28.27 0 15 LAB 12/14/04 28 12 N/A 6 28.27 0 16 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 3000 ReSults to Date: N/A CC: ST. ANDREWS LAND COMPANY. HENNESSEY ENGINEERING, CITY OF COPPELL Respectfully Submitted By: ~ of Alpha Testing, Inc. Our test results and reports are for the exclusive use of the Client (and their designated recepients on file in our office) and shall not be reproduced and/or disfobutod except with express approval of ALPHA The use of our name and test results must receive our written approval Test results and repo~s apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens Geotechnicel Engineering * Construction Materials Testing * Environmentel Engineering * Consulting 39935 ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 Concrete Compression Test Report Teeted For: ST. ANDREWS LAND COMPANY ATFN: TERRY HOLMES 2629 DICKERSON PKVVY, STE 110 CARROLLTON, TX 75007 Fax Number: (972) 242-2931 Project De.c: ST. ANDREWS ESTATES OFF DEFOREST RD JUST WEST OF STRATFORD LN Our Report No.: 04219-53 leeue Date: 12/01/2004 FIELD DA TA Placement Location: PAVING, STONEWICK LN. {~ STATION 0+50 Date Placed: 11/16/04 Time Placed: 11:30 AM Slump (ASTM C.t43): 2.5 Air Content: 4.0 (ASTM C-173) Air Temperature: 68 Specimen Temperature: 84 Date Received: 11/17104 Deliver/Method: PICKED UP BY ALPHA Field Data Submitted By: ALEGRIA, ROBERT Mix Data Submitted By: LMC Plant Number: 3-3600 Oellvery Ticket No.: 3185466 Mede By: ALPHA Cured Specification: ASTM C-31 CYLINDER COMPRESSION TEST RESUL TS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: T~/pe: Spec: Te~ted: (Day~): Length Width Diameter Sq. In. Load: PSi: 17 LAB C-1231 11/23/04 7 12 N/A 6 28.27 118810 4200 18 LAB 12/14104 28 12 N/A 6 28.27 0 19 LAB 12/14/04 28 12 N/A 6 28.27 0 20 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 3000 ReSults to Date: N/A CC: ST. ANDREWS LAND COMPANY, HENNESSEY ENGINEERING, CITY OF COPPELL ,/ Respectfully Submitted By: ~/ of Alpha Testing, inc. .'t- Our test results and reports are for the exclusive use of the Client (and their designated recepients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samptss tested and/or obsen/ed, and are not indicative of the quarities of apparenUy identical or similar specimens. Geotechnical Engineering * Conetroctlon Materials Tearing * Environmental Engineering * Consulting 39936 ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 Concrete Compression Test Report Tested Fro': ST. ANDREWS LAND COMPANY A'CrN: TERRY HOLMES 2629 DICKERSON PKWY, STE 110 CARROLLTON, TX 75007 Fax Number: (972) 242-2931 Project Des¢: ST. ANDREWS ESTATES OFF DEFOREST RD JUST WEST OF STRATFORD LN Our Report No.: 04219-54 Issue Date: 12/01/2004 FIELD DA TA Placement Location: Date Placed: Time Pla~ed: Slump (AfTM C-143): Air Content: Air Temperature: PAVING, ST. ANDREWS LN. ~ STATION 8+00 11/16/04 1:15 PM 3,5 4.5 (ASTM C-173) 68 Specimen Temperature: 86 Date Received: 11117104 Delivery Method: PICKED UP BY ALPHA Field Data Submitted By: ALEORIA, ROBERT Mix Data Submitted By: LMC Plant Number: 3-3600 Delivery Ticket No.: 3186484 Made By: ALPHA Cured Specification: ASTM C-31 CYLINDER COMPRESSION TEST RESULTS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Ama: Max No.: T~/pe: Spec: Tested: (Davis): Lenl~th Width Diameter Sq. In. Load: PSI: 21 LAB C-1231 11/23/04 7 12 N/A 6 28.27 131590 4650 22 LAB 12/14104 28 12 N/A 6 28,27 0 23 LAB 12/14/04 28 12 N/A 6 28.27 0 24 LAB HOLD HOLD 12 N/A 6 28.27 0 : Specifications: 28 3000 Results to Date: N/A CC: ST. ANDREWS LAND COMPANY, HENNESSEY ENGINEERING, CITY OF COPPELL / Respectfully Submitted By: ~! of Alpha Testing, Inc. Our test results and reports are for the exclusive use of the Client (and their designated recepients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA, The use of our name and test results must receive our whtten approval Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 39937 ALPHA TESTING, iNC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 Concrete Compression Test Report Tested For: ST. ANDREWS LAND COMPANY All'N: TERRY HOLMES 2629 DICKERSON PKWY, STE 110 CARROLLTON, TX 75007 Fax Number: (972) 242-2931 Project Desc: ST. ANDREWS ESTATES OFF DEFOREST RD JUST WEST OF STRATFORD LN Our Report No.: 04219-55 Issue Date: 12/01/2004 FIELD DA TA Placement Location: PAVING, ST. ANDREWS LN ~ STATION 6+00 Date Placed: 11/16/04 Time Placed: 2:15 PM Slump (ASTM C-t43): 3,5 Air Content: 5.0 (ASTM C-173) Air Temperature: 68 Specimen Temperature: 87 Date Received: 11117/04 Delivery Method: PICKED UP BY ALPHA Field Data Submitted By: ALEGRIA, ROBERT Mix Data Submitted By: LMC Plant Number: 7-3600 Delivery Ticket No.: 7147125 Made By: ALPHA Cured Specification: ASTM C-31 CYLINDER COMPRESSION TEST RES UL TS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Ama: Max No.: T)'pe: Spec: Tested: (Da~is): Length Width Diameter Sq. In, Load: PSI: 25 LAB C-1231 11/23/04 7 12 N/A 6 28.27 127220 4500 26 LAB 12/14/04 28 12 N/A 6 28,27 0 27 LAB 12/14/04 28 12 N/A 6 28.27 0 28 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 3000 Results to Date: N/A CC: ST. ANDREWS LAND COMPANY, HENNESSEY ENGINEERING, CITY OF COPPELL ./ Respectfully Submitted By: /'.~ of Alpha Testing, Inc. Our test results and reports are for the exclusive use of the Client (and their designated recepients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA The use of our name and test results must receive our written approval Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently idenlical or similar specimens. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 3~938 ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 Concrete Compression Test Report Tested For: ST. ANDREWS LAND COMPANY ATrN: TERRY HOLMES 2629 DICKERSON PKWY, STE 110 CARROLLTON, TX 75007 Fax Number: (972) 242-2931 Project Desc: ST. ANDREWS ESTATES OFF DEFOREST RD JUST WEST OF STRATFORD LN Our Report No.: 04219-56 Issue Date: 1210112004 FIELD DATA Placement Location: PAVING, ST. ANDREWS LN. ~ STATION 4+00 Date Placed: 11/16104 Time Placed: 2:55 PM Slump (ASTM C-143): 3.5 Air Content: 5.0 (ASTM C-173) Air Temperature: 68 Specimen Temperature: 85 Date Received: 11117/04 Delivery Method: PICKED UP BY ALPHA Field Data Submitted By: ALEGRIA, ROBERT Mix Data Submitted By: LMC Plant Number: 3-3600 Delivery Ticket No.: 3186503 Made By: ALPHA Cured Specification: ASTM C-31 CYLINDER COMPRESSION TEST RESUL TS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Ama: Max No.: Type: Spec: Tested: (Days): Lan~lth Width Diameter Sq. In. Load: PSI: 29 LAB C-1231 11/23/04 7 12 N/A 6 28,27 118440 4190 30 LAB 12/14/04 28 12 N/A 6 28.27 0 31 LAB 12/14/04 28 12 N/A 6 28.27 0 32 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 3000 Results to Date: AVA CC: ST. ANDREWS LAND COMPANY, HENNESSEY ENGINEERING, CITY OF COPPELL Respectfully Submitted By: /',~./ of Alpha Testing, Inc. Our test results and reports are for the exclusive use of the Client (an(/their designated recepients on file in our office) and shall not be reproduced and/or distnbuted except ~th express approval of ALPHA. The use of our name and test results must receive our written approval Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Geotechnical EnginesHng * Construction Materials Testing * Environmental Engineering * Consulting 39939 ALPHA TESTING, INC. 2209 wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 Concrete Compression Test Report Tested For: ST. ANDREWS LAND COMPANY AI-I'N: TERRY HOLMES 2629 DICKERSON PKWY, STE 110 CARROLLTON, TX 75007 Fax Number: (972) 242-2931 Project Desc: ST. ANDREWS ESTATES OFF DEFOREST RD JUST WEST OF STRATFORD LN Our Report No.: 04219-57 Issue Date: 12/01/2004 FIELD DA TA Plauement Location: Date Plaeed: Time Placed: Slump (ASTM C-t43): Air Content: Air Temperature: PAVING, ST. ANDREWS LN. @ STATION 1+34.37 11/16/04 4:00 PM 3.5 4.5 (ASTM C-173) 68 Specimen Tempemturo: 87 Date Received: 11/17/04 Delivery Method: PICKED UP BY ALPHA Field Data Submitted By: ALEGRIA, ROBERT Mix Data Submitted By: LMC Plant Number: 3-3600 Delivery Ticket No.: 3186523 Made By: ALPHA Cured Specification: ASTM C-31 CYLINDER COMPRESSION TEST RESUL TS Lab Cum Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSh 33 LAB C-1231 11/23/04 7 12 N/A 6 28.27 107370 3800 34 LAB 12/14/04 28 12 N/A 6 28.27 0 35 LAB 12/14/04 28 12 N/A 6 28.27 0 36 LAB HOLD HOLD 12 N/A 6 28,27 0 Specifications: 28 3000 Res"lte to Date: N/A CC: ST. ANDREWS LAND COMPANY, HENNESSEY ENGINEERING, CITY OF COPPELL Respecffurly Submitted By: ,,/~ of Alpha Testing, Inc. Our test results and reports are for the exclusive use of the Client (and their designated recepients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens Geotechnlcal Engineering * Construction Materials Testing * Environmental Engineering * Consulting 39940