Freeport NIP(8.0)-LR041215Client: Jneers Duke Realty Services, LP Mr. Brian Straley 5495 Belt Line Rd., Ste 360 Dallas TX 75254 Project: Freeport XI & XII Coppell, Texas 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste~ 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Services: Report No.: 222867 Project No.: 049245 Date of Service: 11/13/2004 Report Date: 12/15/2004 Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive sh-ength samples and briag samples back to the laboratory for curing and testing ia accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP (in): AIR (%): TEST METHOD: CONTP, ACrOm Duke Construction CONCRETE SUPPLIER: SoutherI1 Star PLATO': 27 SPECIFICATION REQUIREMENTS 4000 psi ~ 28 Days 5" maximum 3%-5% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C- 1231 ASTM C-39 MEASURED MIXDESlGN I.D.: 7752 SLUM~ PLACEMENT DATE: 11/13/2004 (inches) WEAIltI~R CONDITIONS: Cloudy 5.0 TIME SAMPLED: 5:38alTI BATCH TIME: 5:00am TEMPERATURE (F)- AIR 50 F CONCRETE: 65 F THUCKNO: 8 T~C~C~TNO: 756587 AIR cowrENT (%): 3.9 tr~rr WEIGHT (pc/): NA OVERALL PLACEMENT LOCATION: Paving, 25' from southwest comer, 420' going north 50' wide, and 1000' fi.om southwest comer, 500' going norflt, 50' wide SAMPLE LOCATION: REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" 110' from southwest comer going noah, 25' east on paving CYLINDER MAXIMUM COMPRESSIVE MARKED DATE AGE DIAMETER AREA LOAD STRENGTH FRACTURE SET NO. TESTED (days) (inches) (sq.in.) (lb~. force) (psi) TYPE 2 I 11/20/2004 7 6.00 28.26 129820 4590 Unbonded Cap 2 2 12/11/2004 28 6.00 28.26 165910 5870 Unbonded Cap 2 3 12/11/2004 28 6.00 28.26 157750 5580 Unbonded Cap Average 5730 2 4 Hold Water added at site: 10 gallons LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no r~sponsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by pemons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the wrilten approval of Rone Engineers, Ltd. 015S Page 2 of 7 Client: ineers Duke Realty Services, LP Mr. Brian Straley 5495 Belt Line Rd., Ste 360 Dallas TX 75254 Project: Freeport XI & XII Coppell, Texas 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Report No.: 222867 Project No.: 049245 Date of Service: 11/13/2004 Report Date: 12/15/2004 Obtain samples of fi'esh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laborato~ for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP On): AIR (%): TEST METHOD: co~croR: Duke Construction CONCRETE SUPPLIER: Southern Star PLANT: 27 SPECIFICATION REQUIREMENTS 4000 psi ~ 28 Days 5" maximum 3% - 5% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-1231 ASTM C-39 MEASURED MIX DESIGN I.D.: 7752 SLUM~ pLACEMENT DATE: 11/13/2004 (inch.) WEATHER CONDITIONS: Cloudy 5.5 TIME SAMPLED: 6:17am BATCH nM~: 5259am TEMPERATURE (F) - Am 50 F CONCRETE: 63 F ~VCKNO: 931 ~CY~TNO: 756600 AIR CONTENT (%): 4.1 UNIT WEIGHT (pot): NA OVERALL PLACEMENT LOCATION: Paving, 25' fxom southwest comer, 420' going north 50' wide, and 1000' from southwest comer, 500' going north, 50' wide SAMPLE LOCATION: REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" 215' fi.om southwest comer going north, 20' east on paving CYLINDER MAXIMUM COMPRESSIVE ]~kRKED DATE AGE DIAMETER AREA LOAD STRENGTH FRACTURE SET NO. TESTED (days) (inch~s) (sq.ia.) 0lin force) (psi) TYPE 3 1 11/20/2004 7 6.00 28.26 122540 4330 Unbonded Cap 3 2 12/11/2004 28 6.00 28.26 156400 5530 Unbonded Cap 3 3 12/11/2004 28 6.00 28.26 156940 5550 Unbondcd Cap Average 5540 3 3 Hold LIMITATIONS: The test results presented he~in were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject mat~' provided by persom or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01SS Page 3 of 7 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, StP. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Client: Duke Realty Services, LP Mr. Brian Styaley 5495 Belt Line Rd., StP 360 Dallas TX 75254 Report No.: 222867 Project No.: 049245 Date of Service: 11/13/2004 Report Date: 12/15/2004 Project: Freeport XI & XII Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUM1a On): AIR (%): TEb~ METHOD: CO~mnCTOm Duke Construction CONCRETE SUPPLIER: Southcro Star PLANT: 27 SPECIFICATION REQUIREMENTS 4000 psi ~ 28 Days 5" maximum 3% - 5% ASTM C- 172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-1231 ASTM C-39 MEASURED MIX DESIGN I.D.: 7752 SLUM~ PLACEMENT DATE: 11/13/2004 (inches) WZATh~a commons: Cloudy 6.5 TIMESAM~LED: 7144am BATCHTIME: 7:02am TEM~EP.A~rP.r (F)- AIR 51 F CONCa~TE: 67 F TRVCKNO: 1015 TICKET NO: 756609 AIR CONTENT (%): 4.1 ~ wriarrr (pc0: NA OVERALL PLACEMENT LOCATION: paving, 25' from southwest como', 420' going north 50' wide, and 1000' fi.om southwest comer, 500' going north, 50' wide SAMPLE LOCATION: REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" 320' from southwest comer going north, 32' east on paving CYLINDER MAXIMUM COMPRESSIVE MARKED DATE AGE DIAMETER AREA LOAD STRENGTH FRACTURE SET NO. TESTED (days) 0nches) (sq.in.) (lbs. force) (psi) TYPE 4 1 11/20/2004 7 6.00 28.26 121640 4300 Unbonded Cap 4 2 12/11/2004 28 6.00 28.26 143870 5~090 j5090 Unbonded Cap 4 3 12/11/2004 28 6.00 28.26 141730 [, 501~ Unbonded Cap Average 4 4 Hold Water added at site: 10 gallons LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We ~ssume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no conlxol. Our Ietlers and reports are for the exclusive use of the cliems to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01ss Page 4 of 7 Client: Duke Realty Services, LP Mr. Brian Straley 5495 Belt Line Rd., Ste 360 Dallas TX 75254 Project: Freeport XI & XII Coppell, Texas ;ers 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Services: Report No.: 222867 Project No.: 049245 DateofService: 11/13/2004 Report Date: 12/15/2004 Obtain samples of fresh coner~e at the placement locations, perform required field testing, east compressive sa'ength samples and bring samples back to the laboratory for curing and testing in accordance with applicable slandarcls. PROJECT DATA STRENGTH: SLUMP (in): AIR (%): TEST METHOD: CONTRACTOR: Duke Construction CONCRETE SUPPLIER: Southerll Star PLA~: 27 SPECIFICATION REQUIREMENTS 4000 psi ~ 28 Days 5" maximum 3% - 5% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C- 1064 ASTM C-1231 ASTM C-39 MEASURED ~ DESIGN I.D.: 7752 SLUME PLACEMENT DATE: 11/13/2004 (inches) WEAr.~.R com>moNs: Cloudy 6.0 TIME SAMPLED: 8:19am BATCHTIME: 8:10am TEMEEP. nTta~ (~- ~J~ 51 E CONCRETE: 66 V TRUCK~O: 648 TICI~T NO: 756618 Am CONTENT (%): 3.9 UNITWEIGHT(pef): NA OVERALL pLACEMENT LOCATION: Paving, 25' from southwest coma, 420' going nor~ 50' wide, and 1000' fi.om southwest comer, 500' going north, 50' wide SAMPLE LOCATION: REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" 30' fi-om southwest comer of#2 placement going 20' east on paving CYLINDER MAXIMUM COMPRESSIVE ~ DATE AGE DIAMETER AREA LOAD STRENGTH FRACTURE SET NO. TESTED (days) 0aches) (sq.in.) Obs. force) (psi) TYPE 5 1 11/20/2004 7 6.00 28.26 116320 4110 Unbonded Cap 5 2 12/11/2004 28 6.00 28.26 146130 5170 Unbonded Cap 5 3 12/11/2004 28 6.00 28.26 144380 5110 Unbonded Cap Average 5140 5 4 Hold Water added at site: 5 gallons LIM/TATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, p~rformanc~, etc.) or any other feature of similar subject mat/er provided by persons.or condi~iom over w~ich we have no. ~e&ontxol. 0~' letters ,and reports are for the exclusive use of the clients to whom they ate addressed and shall not be raprodueed except m full w~thou~ the written approval oz t~one engineers, Lta. 01SS Page 5 of 7 Client: ineers Duke Realty Services, LP Mr. Brian S~aley 5495 Belt Line Rd., Ste 360 Dallas TX 75254 Project: Freeport XI & XII Coppell, Texas 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Services: Report No,: 222867 Project No.: 049245 Date of Service: 11/13/2004 Report Date: 12/15/2004 Obtain samples of fi.esh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP (ia): AIR (%): TF.~T METHOD: CONTRACTOR: Duke Construction CONCRETE SUPPLIER: - Southelll Stat PLANT: 27 SPECIFICATION REQUIREIVI~NTS 4000 psi ~ 28 Days 5" maximum 3% - 5% ASTM C-172 ASTM C-31 ~ ASTM C-143 ASTM C-231 ASTlVl C-1064 ASTM C-1231 ASTM C-39 MEASURED MIX DESIGN I.D.: 7752 SLUMP pLACEMENT DATE: 1 1/13/2004 (inc~) Wr.~YHEI~ CONDITIONS: Cloudy 5.75 TIMESAMI~LED: 9:3lam BATCHTIME: 8:50am TEMPERATURE (F)- AIR 51 F CONCRETE: 65 F ~VCKNO: 837 TIC~TNO: 608407 AIR CONTENT (%): 3.9 UNIT WEIGHT (pel): NA OVERALL PLACEMENT LOCATION: Paving, 25' from southwest come~, 420' going north 50' wide, and 1000' from southwest comer, 500' going north, 50' wide SAMPLE LOCATION: REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" 100' fi.om southwest comer of#2 placement going 10' east on paving CYLII~DER MAXIMUM COMPRESSIVE MARKED DATE AGE DIAMETER AREA LOAD STRENGTIcI FRACTURE SET NO. TESTED (days) 0aches) (sq.ia.) (lbs. force) (psi) TYPE 6 I 11/20/2004 7 6.00 28.26 112910 3990 Unbonded Cap 6 2 12/11/2004 28 6.00 28.26 133280 4710 Unbonded Cap 6 3 12/11/2004 28 6.00 28.26 134060 4740 Unbonded Cap Average 4730 6 4 Hold Water added at site: 10 gallons LIlvfiTATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons.or condi~ons over w~ich we have.no~ ~control~ O~r lette.~ ~and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except m full without the written approvm oI Kone t;ngme~rs, Lta. 0ISS Page 6 of 7 Client: ineers Duke Realty Services, LP Mr. Brian Straley 5495 Belt Line Rd., Ste 360 Dallas TX 75254 Project: Freeport XI & XII Coppell, Texas 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Services: Report No.: 222867 Project No.: 049245 Date of Service: 11/13/2004 Report Date: 12/15/2004 Obtain samples of fi~sh concrete at the placement locations, perform required field testing, cast compressive s~'ength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP (in): AIR (%): TEST METHOD: coNT~Acrom Duke Construction CONCRETE SL~PLIER: Southern Star pta~avr: 27 SP~Ct~CA~O~ REQVn~mNTS 4000 psi @ 28 Days 5" maximum 3% - 5% ASTM C- 172 ASTM C-31 ASTM C-143 ASTM C-231 ASTIVf C-1064 ASTM C-1231 ASTM C-39 MEASURED MIX DESIGN I.D.: 7752 SLVM~ PLACEMENT DATE: 11/13/2004 (inches) W~ATHER CONDmONS: Cloudy 6.25 TIME SAMPLED: 10:17am BATCHTIME: 9:37am TEMPERATURE (F)- AIR 52 V CONCRETE: 64 V T~VCK NO: 1883 TIC~ET NO: 756633 AIR CONTENT (%): 4.0 UNIT WEIGHT (pc0: NA OVERALL pLACEMENT LOCATION: Paving, 25' from southwest comer, 420' going north 50' wide, and I000' from southwest corner, 500' going north, 50' wide SAMPLE LOCATION: REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" 210' from southwest comer of#2 placement, going 30' east on paving CYLINDER biARK~D DATE AGE SET NO. TESTED (days) 7 1 11/20/2004 7 DIAMETER AREA (inches) (sq.in.) 6.00 28.26 MAXIMUM COMPRESSIVE LOAD STRENGTH Obs. force) (psi) 111550 3940 TYPE Unbonded Cap 7 2 12/11/2004 28 7 3 12/11/2004 28 6.00 28.26 6.00 28.26 140330 4960 142290 5030 Average 5000 Unbonded Cap Unbonded Cap 7 4 Hold Water added at site: Technician: Kent Reiser Report Distribution: (1) Duke Realty Se~ices, LP (1) Ex'mm~t (1) City of Coppell (i) City of Coppell t0 gallons Stoned: 3:30am Finished: lO:30am ~ K. Scott Watson, AET CMT Op~ations Manager LIMITATIONS: The lest results presented herein were prepared based upon the specific samples provided for testing, We assume no responsibility for variation m quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive nsc of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01SS Page 7 of 7 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive~ Fort Worth, TX 76118 6300 Rothway, Stp. 150, Houston, TX 77040 Corporate Phone: (214) 650-9745 CONCRETE COMPRESSIVE STRENGTH TEST Client: Project: Services: Duke Realty Services, LP Mr~ Brian St~aley 5495 Bek Line Rd., Ste 360 Dallas TX 75254 Report No.: 222866 Project No.: 049245 Date of Service: 11/13/2004 Report Date: 12/15/2004 Freeport XI & XII Coppell, Texas com..scrota Duke Construction CONCRETE SUPPLIER: Southevfl Star PLn~: NA SPECH~ICATION REQUIREMENTS STRENGTH: SLUMP (in): AIR (%): TEST METHOD: 4000 psi ~ 28 Days 3" - 5" NA ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-1231 ASTM C-39 M~ DESIGN I.D.: NA PLACEMENT DnT~: 11/13/2004 WEATHER CONDITIONS: Cloudy TI~ESAMPLED: ll:45am BATCHTIME: NA TEMEERATURE OF) - AIR 54 F CONCRETE: 68 F THVCKNO: NA TICKET NO: NA AIR CONTENT (%): 2.3 UNIT WEIGHT (Pef): NA OVERALL pI~ACEMENT LOCATION: Tilt wall panels 14, 18, and 20 MEASURED SLUMP (inches) 4.75 SAMPLE LOCATION: REPORT OF TESTS Concrvte Compressive Cylinder 6' x 12" Panel 18 CYLINDER MARKED DATE SET NO. TESTED 1 1 11/20/2004 1 2 12/11/2004 1 3 12/I 1/2004 1 4 Hold Technician: Kent Relser Report Distribution: ~ (1) Duke Realty Services. I~° ~, (1) Ex~raaet (1) City of Coppell (1) city of Coppoli AGE DIAMETER AREA (days) (inches) (sq.in.) 7 6.00 28.26 28 6.00 28.26 6.00 28.26 ~rted: ]l:00am MAXIMUM COMPRESSIVE LOAD STRENGTH FRACTURE (lbs. force) (psi) TYPE 141570 174030 173930 Average .~---)Unbonded Cap ~ 6150 ~/Unbonded Cap (~~0 Unbonded Cap Finished: 12:45pm tK. Scott Watson, AET CMT Operations Manager LIMITATIONS: Thc test r~sults presented h~rcm were prapared based upon thc specific samples provided for testing. Wc assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matra' provided by persons or conditions over which we have no control. Our letters and x~potXs are for thc exclusive use of the clients to whom they are addressed and shall not be reproduced exc~pt in full without thc written approval of Rone Engineers, Lut. OISS Page I of 1 Client: ineers Duke Realty Services, LP Mr. Brian Stxaley 5495 Belt Line Rd., Ste 360 Dallas TX 75254 Project: Freeport XI & XII Coppell, Texas 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 6~0-9745 CONCRETE COMPRESSIVE STRENGTH TEST Report No.: 222867 Project No.: 049245 Date of Service: 11/13/2004 Report Date: 12/15/2004 Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP (in): AIR (%): TEST METHOD: CONTRACTOR: Duke Construction CONCRETE SUIPLIER: Southern Star PLAInt: 27 SPECi~ iCATION REQUIREMENTS 4000 psi ~ 28 Days 5" maximum 3% - 5% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-1231 ASTM C-39 MEASURED MIX DESIGN I.D.: 7752 SLUMP PLAczMENT DATE: 11/13/2004 (inches) W~T~mR CO~ITIONS: Cloudy 4.75 TIME SAMPLED: 5:0211111 BATCIt TIME: 4:30am TEMPERATURE (F)- AIR 49 F CONC~,.~TE: 65 F Tm~CK NO: 1827 TICKET NO: 756579 AIR CONTENT (%): 3.8 ~ WEiG~rr (pc0: NA OVERALL pLACEMENT LOCATION: Paving, 25' fi.om southwest comer, 420' going north 50' wide, and 1000' f~ra southwest comer, 500' going north, 50' wide SAMPLE LOCATION: REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" 95' from southwest comer going north, 10' east on paving CYLINDER M.4JIKED DATE AGE SET NO. TESTED (days) MAX/MUM COMPRESSIVE DIAMETER AREA LOAD STRENGTH FRACTURE (inches) ' (sq.in.) (lbs. force) (psi) TYPE 1 I 11/20/2004 7 6.00 28.26 128050 4530 Unbonded Cap 1 2 12/11/2004 1 3 12/11/2004 1 4 Hold 28 6.00 28.26 155420 5500 Unbonded Cap 28 6.00 28.26~ ~I~ UnbondedCap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions ovex which we have no contxoI. Our leaers and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers. Ltd. 01SS Page 1 of 7