Loading...
SS9402A-LR 960501ALPHA TESTING, INC. 2209 Wisconsin St. Suite 100 Dallas, Texas 75229 (214) 620-8911 REPORT OF CONCRETE COMPRESSION TEST TESTED FOR: RIVER VALLEY ENTERPRISES ROCKWALL, TEXAS DATE OF ISSUE: MAY 1, 1996 PROJECT GRAPVINE THREE COPPELL, TEXAS OUR REPORT NO.: 95767-16 FIELD DATA LOCATION OF CONCRETE PLACEMENT DRIVE WAY ADJACENT TO CHEVRON STATION AT INTERSECTION OF BELTLINE AND DENTON ?APP DATE PLACED 0 4 / 1 6 / 9 6 TIME 10: 10 SLUMP (ASTM C-143) 5.0 AIR CONTENT (ASTM C-231 [] OR 0-173 []) 4.7 AIR TEMPERATURE 6 8 CONCRETE TEMPERATURE 7 9 DATE RECEIVED 0 4 / 17 / 9 6 FIELD DATA SUBMITTED BY ZM PLANT 1 DELIVER TICKET NO 13514 MIX PROPORTIONS (SSD) CEMENT WATER N / A FINE AGGREGATE N / A COARSE AGGREGATE N ADMIXTURE N MIX DATA SUBMI~FED BY RED I -H/I X SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C-617 ~ OR C-1231 [] COMPRESSION TEST RESULTS (NOMINAL CYLINDER SIZE 6" X 12") (ASTM C-39) LAB TYPE DATE AGE TOTAL AREA "COMPRESSIVE NO. CURING TESTED DAYS LOAD STRENGTH, PSI 5 LAB 05/01/96 15 88,396 28.27 3,130 6 LAB 05/14/96 28 106,622 28.27 3,770 7 LAB 05/14/96 28 102,983 28.27 3,640 8 LAB HOLD H 28.27 Specifications 28 _ 3,600 COMPUDATA-CG01083 34 REMARKS k~'~Cylinders made by ALPHA representative. [] Cylinders made by Architect's or Contractor's representative. ~Cylinders picked up by ALPHA laboratory. L~l Cy[inders delivered to ALPHA laboratory. [~'~npressions test results comply with applicable specifications. [ ] Compression test results do not comply with applicable specifications,