SS9402A-LR 960501ALPHA TESTING, INC.
2209 Wisconsin St.
Suite 100
Dallas, Texas 75229
(214) 620-8911
REPORT OF CONCRETE
COMPRESSION TEST
TESTED FOR: RIVER VALLEY ENTERPRISES
ROCKWALL, TEXAS
DATE OF ISSUE: MAY 1, 1996
PROJECT
GRAPVINE THREE
COPPELL, TEXAS
OUR REPORT NO.:
95767-16
FIELD DATA
LOCATION OF CONCRETE PLACEMENT
DRIVE WAY ADJACENT TO CHEVRON STATION AT
INTERSECTION OF BELTLINE AND DENTON ?APP
DATE PLACED 0 4 / 1 6 / 9 6
TIME 10: 10
SLUMP (ASTM C-143) 5.0
AIR CONTENT (ASTM C-231 [] OR 0-173 []) 4.7
AIR TEMPERATURE 6 8
CONCRETE TEMPERATURE 7 9
DATE RECEIVED 0 4 / 17 / 9 6
FIELD DATA SUBMITTED BY ZM
PLANT 1
DELIVER TICKET NO 13514
MIX PROPORTIONS (SSD)
CEMENT
WATER N / A
FINE AGGREGATE N / A
COARSE AGGREGATE N
ADMIXTURE N
MIX DATA SUBMI~FED BY RED I -H/I X
SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C-617 ~ OR C-1231 []
COMPRESSION TEST RESULTS
(NOMINAL CYLINDER SIZE 6" X 12")
(ASTM C-39)
LAB TYPE DATE AGE TOTAL AREA "COMPRESSIVE
NO. CURING TESTED DAYS LOAD STRENGTH, PSI
5 LAB 05/01/96 15 88,396 28.27 3,130
6 LAB 05/14/96 28 106,622 28.27 3,770
7 LAB 05/14/96 28 102,983 28.27 3,640
8 LAB HOLD H 28.27
Specifications 28 _ 3,600
COMPUDATA-CG01083 34
REMARKS
k~'~Cylinders made by ALPHA
representative.
[] Cylinders made by Architect's
or Contractor's representative.
~Cylinders picked up by ALPHA
laboratory.
L~l Cy[inders delivered to ALPHA
laboratory.
[~'~npressions test results comply with
applicable specifications.
[ ] Compression test results do not comply
with applicable specifications,