Loading...
SS9402B-LR 960314 Ellerbee-Walczak, Inc. CONSTRUCTION MATERIALS TESTING COMPRESSIVE STRENGTH (6x12" CYL.) AND/OR FLEXURAL STRENGTH TEST (CENTERPOINT OR 3RD POINT) REPORT NO.: PB112cyl.doc PROJECT: Grapevine IV CLIENT: Pate Bros. DATE OF PLACEMENT: 3/14/96 CONCRETE SUPPLIER: Lattimore STRENGTH REQ./28 DAYS: 4200 DESIGN ID #: 42 TECHNICIAN: TEST LOAD STRENGTH ID # SLUMP AGE DATE X 1000 PSi TYPE ADDN. INFO. I 7 03/21 109.0 3856 2 7 03/21 106.0 3750 3 28 04/11 135.0 4775 4 28 04/11 138.5 4899 Ticket 22534 Truck 450 Time 6:00 LOCATIONS: Manhole Sta. 26 +50 on Bethel School Rd. Cyls. made by others, picked up by lab cc: Pate Bros. CoppelI-Gareth, Campbell o~uu ~o". ~reeway, Suite A-1 Laboratory: [817) 293-0111 Fort Worth, Texas 76134 (817) 293-0257 Fax: (817) 596-0941