REPORT OF REINFORCING STEEL INSPECTION
Client:
Duke Realty Services, LP
Mr. Brian Straley
5495 Belt Line Rd., Ste 360
Dallas TX 75254
Project: Freeport XI & XtI
Coppell, Texas
Report No.: 223672
Project No.: 049245
Date of Service: 12/03/2004
Report Date: 12/08/2004
Services: Reinforcing Steel Inspection
Report of Inspection
On this date, a Rone Engineers, Ltd. representative(s) arrived on site as
scheduled to perform a Reinforcing Steel Inspection. The results are attached.
Technician Time: 6:00am - 7:00am and 8:15am - 8:45am
Page 1 of 3
Technician: Bobby Robinson
Report Distribution:
(I) Duke Realty Services, LP
(l) Extrmaet
(I) City of Coppell
(1) City of Coppell
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing We ~-ssume no responsibilily for variation in quality
(composition, appearance, performance, etc) or any other feature of similar subject matter provided by persons or conditions over which we have no control Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
99TM
RoneE llglneers
8908 Ambassador Row
Dallas, Texas 75247
(214) 630-9745
121 North Rayner
Fort Worth, Texas 76111
(817) 831-6211
Report of
Reinforcing Steel Inspection
Client: ~V_o~e~)~c-._, ~cr~;.c~-~ L-P ReportNo.:
Project
Project: ~r~ ~ ~l~ Date of Service:
Page
Locations and Items Inspected:
Items Inspected: Conforming Non Items Inspected: Conforming Non Items Inspected: Conforming Non
Conforming Conforming Conforming
Placing Drawings ~ Bar Length ~ Column Ties Properly
Approved and Shape Tied and Spaced
Bar Si~ [~ Proper Bar Placement ~ Stirrup Spacing and Type
Bar Grade ~ Properly Tied
Bars Clean ~ Dowel Bars in Place ~ Welded Splices
Number Bars ~ c Proper Cover
Discrepancies / Comments:
Inspector's Signature: (~c~ ~a/~ Time:
#
Client/Contractor Signature: Client/Contractor Copied with Results: Yes / No
R°neEn gill l
8908 Ambassador Row
Dallas, Texas 75247
(214) 630-9745
121 North Rayner
Fort Worth, Texas 76111
(817) 831-6211
Client:
Project:
Report of
Reinforcing Steel Inspection
Report No.:
Project No.:
Date of Service:
Page
Locations and Items Inspected:
Non
Items lnspe*t*d: Conforming Non Items Inspected: Conforming Non Items Inspected: Conforming ] Conforming
Conforming Conforming
Placing Drawings j Bar Length ~ Column Ties Properly
Approved and Shape Tied and Spaced
Bar Size ~ Proper Bar Placement i~/ Stirrup Spacing and Type l/~
Bar Grade ~ Properly Tied t~/ Lapped Splices b/
Bars Clean J Dowel Bars in Place ~ Welded Splices
Form Clean ~ Proper Bar Supports ~ Mechanical Splices
Number Bars ~ Proper Cover b/
Discrepancies / Comments:
Inspector's Signature: ~A¢i ;~
Time: (o~, ~bO,'~ to q:CJ(~j~'---
Client/Contractor Signature: Client/Contractor Copied with Results: Yes / No