Freeport NIP(8.0)-LR041220ineers
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
REPORT OF REINFORCING STEEL INSPECTION
Client:
Project:
Duke Realty Services, LP
Mr. Brian Straley
5495 Belt Li~e Rd., Ste 360
Dallas TX 75254 .~
Freeport XI & XII
Coppell, Texas
Reinforcing Steel Inspection
Report No.: 224518
Project No.: 049245
Date of Service: 12/15/2004
Report Date: 12/20/2004
Report of Inspection
On this date, a Rone Engineers, Ltd. representative(s) arrived on site as
scheduled to perform a Reinforcing Steel Inspection. The results are attached.
Technician Time: 6:00am - 8:30am
Page 1 of 2
Technician: Bobby Robinson
Report Distribution:
(I) Duke Really Services, LP
( 1 ) Extranet
(1) City of Coppell
(1) City of Coppell
~ ~ CMT Operations M~ager
LIMITAT/ONS: The ~:st results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
repons are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
99TM
8908 Ambassador Row
Dallas, Texas 75247
(214) 630-9745
121 North Rayner
Fort Worth, Texas 76111
-(817) 831-6211
Report of
Reinforcing Steel Inspection
Project No.:
Project: ~¢¢4o<:~'~L ,~1 i ,'~tl Date of Service:
Page
Items Inspected: Conforming Non Items Inspected: Conforming Non Items Inspected: Conforming Non
Conforming Conforming Conforming
Placing Drawing~ b~ Bar Length {/./ Column Ties Properly
Approved and Shape Tied and Spaced
Bar Size ~'~ Proper Bar Placement ~ Stimp Spacing and Type ~
Bar Grade ~'~ Properly Tied ~-~ Lapped Splices ~
Bars Clean b/' Dowel Bars in Place ~' Welded Splices
Form Clean / Proper Bar Suppork~ oJ~ Mechanical Splices
Number Bars ~,~ Proper Cover ~/
Discrepancies/Commen( fl~--'lh ~¢Joo~ ~,,,,t,-~ ~c~,~-~ X-~wr CorrectiON ~
,
n .ec or's i na re:
ClienfContractor Signature Contractor Copied with Results: Yes / No
ineers
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, For~ Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
REPORT OF REINFORCING STEEL INSPECTION
Client:
Duke Realty Services, LP
Mr. Brian Straley
5495 Belt Line Rd., Ste 360
Dallas TX 75254
Project: Freeport XI & XI1
Coppell, Texas
Report No.: 224604
Project No.: 049245
Date of Service: 12/15/2004
Report Date: 12/20/2004
Services: Reinforcing Steel Inspection
Report of Inspection
On this date, a Rone Engineers, Ltd. representative(s) arrived on site as
scheduled to perform a Reinforcing Steel Inspection on the west parking lot at
Building XI. Upon arrival, the contractors were still placing and forming the
area to be inspected. The superintendent, Greg Burk, said that he would perform
the inspection because the placement of concrete was scheduled for 4:00am on
12/16/04.
Technician Time: 4:lSpm - 5:45pm
Page 1 of 1
Technician: Bobby Robinson
Report Distribution:
(1) Duke Reall~ Services, LP
(l) Extranet
(1) City of Coppell
(1) CiB' of Coppell
LEMITATIONS: The test results presented herein were prepared b~sed upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc ) or any other feature of similar subject mai/er provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in thll without the written approval of Rone Engineers, Ltd.
99TM Pa~e I of I
ineers
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
Client:
Duke Realty Services, LP
Mr. Brian Straley
5495 Belt Line Rd., Ste 360
Dallas TX 75254
Project: Freeport XI & XII
Coppell, Texas
Report No.: 224519
Project No.: 049245
Date of Service: 12/15/2004
Report Date: 12/20/2004
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
STRENGTH:
SLUMP (in):
AIR (%):
TEST METHOD:
CONTRACTOR: Duke Construction
CONCRETE SUPPLIER: Southern Star
PLANT: 27
SPECIFICATION REQUIREMENTS
3000 psi ~ 28 Days
3" - 5"
4% - 6%
ASTM C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-1231
ASTM C-39
M~X DESIGN I.D.: 7750
PLACEMENT RAXE: 12/15/2004
WEATHER CONDITIONS: Clear
TIME SAMPLED: 9:30am BATCHTIME: 8:44am
TEMPERATURE (F) -AIR 34 v CONCRETE: 44 F
TRUCK NO: 1015 TICKET NO: 761683
AIR CONTENT (%): 4.5 UNITWEIGHT(pc0: NA
OVERALL PLACEMENT LOCATION:
Paving, Building XII north parking lot, west half
SAMPLE LOCATION: 5' southwest from northeast comer
REPORT OF TESTS at north approach
MEASURED
SLUMP
(inches)
4.75
Concrete Compressive Cylinder 6" x 12"
CYLENDER MAXIMUM COMPRESSVCE
MARKZD DATE AGE DIAMETER AREA LOAD STRENGTH FRACTURE
SET NO. TESTED (days) (inches) (sq.in.) (lbs. force) (psi) TYPE
12/18/2004 3 6.00 28.26 63500 2250 Unbonded Cap
12/22/2004 7 0.00 0.00 Unbonded Cap
01/12/2005 28 0.00 0.00 Unbonded Cap
01/12/2005 28 0.00 0.00 Unbonded Cap
Hold
LIMITATIONS: The test results presented herein were prepared b~ed upon the specific samples provided for testing We assume no responsibility for variation in quality
(composition, appearance, performance, etc) or any other feature of similar subject manet provided by persons or conditions over which we have no control Our letters and
reports a~e for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in f~ll without the written approval of Rone Engineers, Ltd
01SS Page 1 of 3
ineers
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
Client:
Duke Realty Services, LP
Mr. Brian Straley
5495 Belt Line Rd., Ste 360
Dallas TX 75254
Project: Freeport XI & XI1
Coppell, Texas
Report No.: 224519
Project No.: 049245
Date of Service: 12/15/2004
Report Date: 12/20/2004
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
STRENGTH:
SLUM~ (in):
AIR (%):
TEST METHOD:
CONTRACTOR: Duke Construction
CONCRE~ SUPPLIER: Southern Star
PLANT: 27
SPECIFICATION REQUIREMENTS
3000 psi ~ 28 Days
3"- 5"
4% - 6%
ASTM C-172
ASTM C-31
ASTM C-143
ASIM C-231
ASTM C- 1064
ASTM C-1231
ASTM C-39
MIX DESIGN I.D.: 7750
PLACEMENT DATE: 12/15/2004
WEATHER CONDITIONS: Clear
TIME SAMPLED: 10:40am BATCHTIME: 10:20am
TEMPERATURE (F) - AIR 40 F CONCRETE: 52 F
TRUCKNO: 923 TICKETNO: 761693
AIR CONTENT (%): 5.3 UNIT'WEIGItT(pcf): NA
OVERALL PLACEMENT LOCATION:
Paving, Building Xll north parking lot, west half
SAMPLE LOCATION: 60' south, 20' east from northwest
REPORT OF TESTS comer
MEASURED
SLUMP
(inches)
5.00
Concrete Compressive Cylinder 6" x 12"
CYLINDER
MARKED DATE AGE
SET NO. TESTED (days)
MAXIMUM COMPRESSIVE
DIAMETER AREA LOAD STRENGTH
(inches) (sq.in.) (lbs. force) (psi)
FRACTURE
TYI'E
2 1 12/18/2004 3 6.00 28.26
2 2 12/22/2004 7 0.00 0.00
2 3 01/12/2005 28 0.00 0.00
2 4 01/12/2005 28 0.00 0.00
2 5 Hold
Water added at site: 5 gallons
66990 2370
Unbonded Cap
Unbonded Cap
Unbonded Cap
Unbonded Cap
L1MTrATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shalI not be reproduced except in fall without the wrigten approval of Rune Engineers, Ltd.
01SS Page 2 of 3
RoneEngineers
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
Client:
Duke Realty Services, LP
Mr. Brian Straley
5495 Belt Line Rd., Ste 360
Dallas TX 75254
Project: Freeport XI & XII
Coppell, Texas
Report No.: 224519
Project No.: 049245
Date of Service: 12/15/2004
Report Date: 12/20/2004
Obtain samples of fi-esh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
STRENGTH:
SLUMP (in):
AIR (%):
TEST METHOD:
CONTRACTOR: Duke Construction
CONCRETE SUPPLIER: Southern Star
PLANT: 27
SPECIFICATION REQUIREMENTS
3000 psi ~ 28 Days
3" - 5"
4% - 6%
ASTM C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-1231
ASTM C-39
MIX DESIGN I.D.: 7750
PLACEMENT DATE: 12/15/2004
WEATHER CONDITIONS: Clear
TIME SAMPLED: 12:20pm BATCHTIME: 12:01pm
TEM]~ERATURE (F) - AIR 50 F CONCRETE: 55 F
TRUCK NO: 1015 T1CRET NO: 761705
AIR CONTENT (%): 5.3 UNIT WEIGHT (pcl): NA
OVERALL PLACEMENT LOCATION:
Paving, Building XII north parking lot, west half
SAMPLE LOCATION: 90' north, 30' east from southwest
REPORT OF TESTS com~
MEASURED
SLUMP
(inches)
6.00
Concrete Compressive Cylinder 6" x 12"
CYLINDER
M~D DATE
SE/ NO. TESTED
MAXIMUM COMPRESSIVE
AGE DIAMETER AREA LOAD STRENGTH FRACTURE
(days) (inches} (sq.in.) (lbs. force) (psi) TYPE
3 1 12/18/2004
3 2 12/22/2004
3 3 01/12/2005
3 4 01/12/2005
3 5 Hold
Water added at site:
3 6.00 28.26 64570 2280 Unbonded Cap
7 0.00 0.00 Unbonded Cap
28 0.00 0.00 Unbonded Cap
28 0.00 0.00 Unbonded Cap
10 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc ) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in fall without the written approval of RODe Engineers, Ltd.
01SS Page 3 of 3
Technician: Nathan WitherelI
Report Distribution:
(I) Duke Realt) Ser~,Jces, LP
(1) Extranet
(I) Cii3, of Coppell
(1) CiB' of Coppell
Started: 6:45am
Finished: 3:30pm
CMT Operations Manager
ineers
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
Client:
Duke Realty Services, LP
Ma'. Brian Straley
5495 Belt Line Rd., Ste 360
Dallas TX 75254
Project: Freeport XI & XII
Coppell, Texas
Report No.: 224520
Project No.: 049245
Date of Service: 12/I5/2004
Report Date: 12/20/2004
Services:
Obtain samples of fi-esh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
STRENGTH:
SLUMP (in):
AIR (%):
TEST METHOD:
CONTRACTOR: Duke Construction
CONCRETE SUPPLIER: 8outherrl Star
PLA~rr: 66
SPECIFICATION REQUIREMENTS
4000 psi ~ 28 Days
3"-5"
NA
ASTM C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-1231
ASTM C-39
MIX DESIGN I.D.: 9349 MEASURED
SLUMP
PLACEMENT DATE: 12/15/2004 (inches)
WEATHER CONDITIONS: Clear 3.25
TIME SAMPLED: 2:30pm BATCHTIME: l:10pm
TEMPERATURE (F) - AIR 49 F CONCRETE: 56 F
TRUCK NO: 8859 TICKET NO: 405554
AIR CONTENT (%): NA UNIT WEIGHT (pcf~: NA
OVERALL PLACEMENT LOCATION:
Building X1, leave-ouls and southwest dock door walls between gridlines A/1 8 to A/3.8 and
A~4.5 to A/7
SAMPLE LOCATION: 20' north, 5' west fi-om southeast
REPORT OF TESTS comer of leave-outs
Concrete Compressive Cylinder 6" x 12"
CYLINDER
MARKED DATE AGE
SET NO. TESTED (days)
MAXIM1JM COMPRESSIVE
DIAMETER AREA LOAD STRENGTH
(inches) (sq.in.) (lbs. force) (psi)
1 1 12/18/2004 3 6.00 28.26
1 2 12/22/2004 7 0.00 0.00
1 3 01/12/2005 28 0.00 0.00
I 4 01/12/2005 28 0.00 0.00
1 5 Hold
Nater added at site: 5 gallons
89560 3170
Unbonded Cap
Unbonded Cap
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature &similar subject malter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Eld.
01SS Page 1 of 2
Report No.: 224520
Project No.: 049245 Client: Duke Really Services, LP
See Report %224519 for technician time.
Technician: Nathan Witherell
Report Distribution:
(1) Duke Real~y Services, LP
( I ) Exxranet
(l) City of Coppell
(1) City of Coppell
Started: Finished:
CMT Operations Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing We ~ssume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject mailer provided by persons or conditions over which we have no control Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the writlen approval of Rone Engineers, Ltd.
01SS Page 2 of 2